Adding An Lcd Smart Management Module; Prerequisites; Procedures - H3C UniServer R3950 G6 Manual

Hide thumbs Also See for UniServer R3950 G6:
Table of Contents

Advertisement

4.
Remove the chassis air baffle. Press the tabs on the air baffle, and then lift the air baffle out of
the chassis.
Installing a chassis air baffle
1.
Install the chassis air baffle. Place the chassis air baffle in the chassis.
2.
Install the access panel:
a. Place the access panel onto the server.
b. Slide the access panel to the server front and close the locking lever. The access panel
snaps into place.
3.
Rack-mount the server. For more information, see
4.
Connect the power cord. For more information, see
5.
Power on the server. For more information, see

Adding an LCD smart management module

Prerequisites

Take the following ESD prevention measures:
Wear antistatic clothing.
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
Do not wear any conductive objects, such as jewelry or watches.
When you replace a component, examine the slot and connector for damages. Make sure the pins
are not damaged (bent for example) and do not contain any foreign objects.

Procedures

1.
Power off the server. For more information, see
2.
Remove the server from the rack. For more information, see
3.
Remove the access panel:
a. Press the button on the locking lever and then lift the locking lever.
The access panel automatically slides to the server rear.
b. Lift the access panel to remove it from the server.
4.
Remove the fan cage. Pull up the ejector levers at both sides of the fan cage and lift the fan
cage to remove it from the chassis.
5.
Remove the drive or blank from the target slot.
6.
Install the LCD smart management module.
a. Connect one end of the LCD module cable to the LCD smart management module.
b. Push the LCD smart management module into the slot until it snaps into place.
c. Connect the other end of the cable to the LCD smart management module connector on the
system board.
7.
Install the fan cage. Place the fan cage into the chassis and close the ejector levers.
8.
Install the access panel.
a. Place the access panel onto the server.
b. Slide the access panel to the server front and close the locking lever. The access panel
snaps into place.
9.
Rack-mount the server. For more information, see
"Rack-mounting the
"Connecting the power
"Powering on the
"Powering off the
"Removing the server from a
"Rack-mounting the
100
server."
cord."
server."
server."
server."
rack."