Summary of Contents for Antunes InfiniSteam IS-1000
Page 1
InfiniSteam IS-1000 Owner’s Manual Manufacturing Number: 9100960 Original Instructions P/N 1011662 Rev F 10/23 CAUTION: Read all instructions before using the unit. www.antunes.com...
But not Service/Technical Assistance....2 problems with the installation or operation for continuous mass production of food. of this product contact Antunes Customer In Case of Damage ........ 2 Service immediately at +1-877-392-7856 Equipment Information to Save ....2 (toll free).
ONLY. y Do not block or cover any openings on the plumbing. Contact Antunes Technical Service for equipment. y Install this unit to comply with the basic adjustment or repair.
To better understand if the water to be used for the boiler meets these requirements, a water quality sample kit (part number 7002105) can be ordered from Antunes for testing. P/N 1011662 Rev F 10/23...
If any parts are missing or NOTE: A 2 inch air gap from the drain Rail Cutout damaged, contact Antunes hose to the floor drain must be IMMEDIATELY at 1-800-253-2991 maintained in order to provide (toll free in the U.S. and Canada)
An ion-exchange water softener or Reverse Osmosis (RO) system are recommended to best attain these water conditions. Consult Antunes Customer Service for more information on and Antunes product that is Drain designed for the InfiniSteam. NOTE: Failure to follow these water...
Leveling the Steamer Double Stacking Steamers Remove Screws NOTE: Installer MUST verify the weight (Optional) restrictions of the table, cart, or NOTE: The InfiniSteam is designed for service rack prior to installation a maximum height of two (2) of the steamer. All warranties steamers.
Operations Status Bar Boiler Temperature Initial Startup Connect the cold water line to the Heater Power water inlet according to Figure 3 on Percentage page 6. (00/100) Plug the power cord into the Water Probe appropriate outlet. Turn on water. State (Wet/Dry) The steamer performs a system...
System Power-up System Power-down Upon application of power, the system To turn the system off, press the will display the following splash Power button behind the display screen. screen. The following screen is displayed. After the steamer is powered-up, it begins operation with this screen.
Programmed Steaming Programmed Steaming Example: The Manual buttons start a steam cycle that counts up until the Cancel Item 1L Steaming Turn the steamer on by pressing box is pressed. the power switch located behind the After pressing Cancel, the steamer display screen.
Steamer Settings The following screen appears: To access the Steamer Settings, press the Tools icon on the display. This opens the Tools screen, shown below. Press the button next to the first setting Press button next to the recipe name, you want to change.
Maintenance Steam Trivets Daily The InfiniSteam requires a minimal amount of maintenance. Daily maintenance helps keep the steamer running smoothly and free of any excess buildup that comes from daily use and wear. These steps should be completed Steam at the end of every day to ensure that the Pans steamer maintains optimum efficiency.
Failure to properly clean and de-scale boiler will cause significant changes in operation Remove top of Cleaning Cartridge by of steamer. Antunes is not pulling it off the plastic housing. responsible for any damage or complications due to negligent Scaled Boiler Examples maintenance of steamer.
Page 14
Deep Clean Cycle. The Deep Clean Cycle should only be 12. Press the check mark symbol to begin preformed when advised by Antunes the Deep Clean Cycle. Technical Support. The Deep Clean will take a minimum of six (6) hours to complete and should be preformed at the end of the night.
Troubleshooting Your Antunes Steamer is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks or activities to make in the event of a problem: Who Services Problem Possible Cause Corrective Action Steamer...
NOTE 0508228 Clean Cycle Support Bracket 0508229 Clean Cycle Plunger Actuator Use only genuine Antunes replacement parts in this unit. Use of parts other than those supplied by the manufacturer will void 0508230 Clean Cycle Bracket Bushing the warranty. 0508231...
Page 17
Item Item Part # Description Part # Description 0512041 Brace Divider 2070142 1/4 Tube X 1/4NPT Female 0512199 Drip Tray 2070143 Elbow,1./4NPT X 1/4 Hose SST 0512200 Drip Tray Plate 2070147 1/4 Tube X 1/8NPT Straight SST 0513573 End Cap, 1.25”SQ 2070175 Tee, 5/16 Tube X 1/4NPTM 0600170...
Page 18
Item Item Part # Description Part # Description Screw, #4-40 x 1/2” LG S.S. Slotted 4010261 Reed Switch Actuator 3040126 Truss Head 4010266 Fixed Pressure Switch 26 PSI 4-40 Flat Head Socket x .312 3040132 2170229 Solenoid Valve .088 Orifice 4040269 Steam Solenoid Valve .12 Orifice 3040140...
This warranty does not cover water pressure problems or failures resulting from improper/incorrect voltage supply. Antunes reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations. Changes to update equipment do not constitute a warranty charge.