Model Number under warranty. IMPORTANT The warranty does not extend to: A.J. Antunes & Co. reserves the right to change specifications and product Serial Number • Damages caused in shipment or dam- design without notice. Such revisions do age as result of improper use.
• This equipment should be serviced • If a chemical cleaner is used, be sure by qualified personnel only. Contact Antunes Technical Service for adjust- it is safe to use on cast aluminum. Observe all precautions and warnings ment or repair.
(MS-150 Only) Plug the power cord into the appropriate power outlet. Refer to the specification plate 4. MS-150: Remove and wash the Wire for the proper voltage. Drawer Trivet, Spatula, Spatula Liner, and Drip Pan (Figure 1) in soap and water.
PROGRAMMING OPERATING INSTRUCTIONS IMPORTANT: 208V and 220/240V Miracle Steamers are factory programmed for the CYC (Total Cycle Time) refers to the total following recommended settings: 1. Turn the power on and allow the unit programmed steam time set for the product. to preheat for approximately 20-30 •...
Drip Pan This LED is only lit for approximately 1 second. 2. MS-150: Remove the Spatula, Spatula Liner, Drip Pan, Top Cover, and Steam FAULT CODES Vent (Figure 7). Figure 7. Daily Cleaning–MS-150...
MONTHLY MAINTENANCE Water Tank Filter The Miracle Steamer utilizes an open steam Wing Nut Generator. Water sprayed onto the Generator surface flashes into steam immediately, Generator Filter Stem but the minerals in the water stay on the Cover Generator surface. A small amount of calcium/ Tank Door mineral deposits are needed for proper opera- Diffuser...
The unit should be unplugged when servicing, except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will be exposed. If the troubleshooting steps listed below do not solve your machine’s problem, contact Antunes Technical Service for further assistance.
Page 10
TROUBLESHOOTING (continued) Problem Possible Cause Corrective Action Unit heats but there is little or no Filter Strainer is restricted. Check and clean the Filter Strainer as described in steam produced the Maintenance section of this manual. Unit is not being cleaned properly (daily/monthly). Clean unit daily and monthly as described in the and/or Maintenance section of this manual.
WIRING DIAGRAM *NOTE: For 208-240 VAC units, the two primary coils are wired in series with one another. For 120 VAC units, the two primary coils are wired in parallel with one another. P/N 1010454 Rev. F 12/16...
LIMITED WARRANTY Equipment manufactured by Roundup Food Equipment Division of A.J. Antunes & Co. has been constructed of the finest materi- als available and manufactured to high quality standards. These units are warranted to be free from electrical and mechanical defects for a period of one (1) year from date of purchase under normal use and service, and when installed in accordance with manufacturer’s recommendations.
Need help?
Do you have a question about the MS-150 and is the answer not in the manual?