Installation

Installation Location

The appliance should be set up in a well ventilated,
dry room.
Energy use and efficient performance of the appli-
ance is affected by the ambient temperature.
The appliance should therefore
– not be exposed to direct sunlight;
– not be installed next to radiators, cookers or
other sources of heat;
– only be installed at a location whose ambient
temperature corresponds to the climate classi-
fication, for which the appliance is designed.
The climate classification can be found on the rating
plate, which is located at the left on the inside of the
appliance.
The following table shows which ambient temperature
is correct for each climate classification:
If installation next to a source of heat is unavoidable,
the following minimum clearances must be main-
tained at the sides of the appliance:
– for electric cookers 3 cm;
– for oil and coal fired ranges 30 cm.
If these clearances cannot be maintained a heat insu-
lating pad is required between the cooker and the
refrigeration appliance.

Your refrigerator needs ventilation

The integrated door of the furniture cabinet largely
seals the installation recess. Appliances for integrat-
ing must therefore be provided with ventilation by
having an opening in the furniture plinth. The warmed
air must be able to be exhausted upwards through
the air shaft on the furniture back. The ventilation
cross-sections should be at least 200 cm
Important note! In order not to impair the function of
the appliance, never cover or obstruct the ventilation
openings.
Installation
See chapter „Installation Instructions".
Please check whether, after installing your appliance
and especially after rehingeing the door, the door
seal seals right round. An untight door seal may lead
22
If the refrigeration appliance is installed next to
another refrigerator or freezer a clearance of 5 cm at
the sides is required, in order to prevent the formation
of condensation on the outside of the appliance.
classification
2
.
to heavy frosting and thereby to a higher power con-
sumption (see also „What to do if...").
Climate
SN
N
ST
T
min. 200 cm
50
min. 200 cm
for an ambient
temperature of
+10 to +32 °C
+16 to +32 °C
+18 to +38 °C
+18 to +43 °C
2
50
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jki 4056Jki 4066