Your refrigerator needs ventilation

Installation option 1 (optimum):
Optimum ventilation of built-in appliances is ensured
through fresh air being able to enter both under the
appliance as well as through an opening in the furni-
ture plinth. The warmed air must be able to be
exhausted upwards through the air shaft (min. 200
2
cm
) on the furniture back.
Installation option 2:
Operation of built-in appliances is possible even with-
out a ventilation opening in the furniture plinth. The
fresh air able to enter under the appliance is sufficient
for ventilation. The function and life of the appliance
are not impaired. The warmed air must be able to be
exhausted upwards through the air shaft (min. 200
2
cm
) on the furniture back. If the appliance is ventila-
ted without a plinth opening, however, the energy
consumption may differ from that specified in the bro-
chure.
Important note! In order not to impair the function of
the appliance, never cover or obstruct the ventilation
openings.

Installation

See chapter „Installation Instructions".
Please check whether, after installing your appliance
and especially after rehingeing the door, the door
seal seals right round. An untight door seal may lead

Electrical connection

Before initial start-up, refer to the appliance rating
plate to ascertain if supply voltage and current values
correspond with those of the mains at the installation
location.
e.g.: AC 220 ... 240 V 50 Hz or
220 ... 240 V ~50 Hz
(i.e. 220 to 240 volts alternating current, 50 Hertz)
The rating plate is inside the appliance on the left.
A correctly installed, earthed socket is required for
the electrical supply. The supply must have a fuse rat-
ing of at least 10 Amps.
min. 200 cm
min. 200 cm
to heavy frosting and thereby to a higher power con-
sumption (see also „What to do if...").
If the socket is not accessible once the appliance is
built in, the electrical installation must include suitable
means of isolating the appliance from the mains (e.g.
fuse, cut-out, current trip or similar with a minimum
contact separation of 3 mm).
Attention: The mains connection cable may only be
replaced by a skilled electrician. Please contact your
dealer or our customer service department for
repairs.
2