Troubleshooting - Fagor FD282NFX Operating Instructions Manual

Table of Contents

Advertisement

9. TROUBLESHOOTING

PROBLEM
The refrigerator does not
operate
The refrigerator vibrates.
The refrigerator or freezer is
not very cold
The motor runs permanently.
CAUSE
• It is not plugged in.
• There is no electrical current
to the plug because the fuse
has blown or the automatic
power limiter has activated.
• The connection controls are
not on.
• The
refrigerator
incorrectly levelled.
• Temperature selection is set
too hot.
• The door is not properly
closed or is opened very
frequently.
• The space between the
skirting board and floor or
the top of the refrigerator has
been covered.
• The refrigerator is exposed
to direct sunlight or a heat
source.
• A large amount of food has
been introduced.
• In No-Frost refrigerators,
there
is
obstructing the ventilation
grilles
• The doors are not properly
closed.
• The doors are opened often.
• The food was introduced
recently.
• Temperature selection in
cold position.
15
• Plug in.
• Change the fuse or reset the
automatic power limiter.
• Switch the controls on.
is
• Level it, with the leveller
bases.
• Set temperature selection to
maximum cold.
• Ensure that the door does not
remain open too long.
• Keep these areas free as
described
"Installation" section in this
manual.
• Relocate the refrigerator or
protect it from these heat
sources.
• Consult the section on
"operation and use of the
refrigerator".
• Remove
something
blocking the air outlet of the
ventilation grilles.
• Close the door properly.
• Avoid opening the door
frequently.
• Wait for the appliance to
return to normal.
• Set the temperature switch to
less cold.
SOLUTION
in
the
any
obstacles

Advertisement

Table of Contents
loading