If the RUN LED flashes at a high frequency, the card is in the startup process, but is not yet operational.
At system startup, the ALM LED will be ON for a while, but it does not mean that the card is faulty
ACTIVE LED
The ACTIVE LED shows the active/standby status of the LSQ1SRPB0. If the ACTIVE LED is ON, the
LSQ1SRPB0 is active; if OFF, the LSQ1SRPB0 is standby.
RESET button
A reset button is provided on the LSQ1SRPB0 for you to reset the card when necessary.

Salience VI-Turbo SRPU-LSQ1SRP1CB0

Applicable models
S7903E
S7906E
S7910E
S7906E-V
Technical specifications
Table 1-51 Technical specifications of LSQ1SRP1CB0
CPU
Boot ROM
Flash memory
DDR SDRAM
Card physical dimensions (H x W x D)
Interfaces
Power consumption
Panel and LEDs
Figure 1-21
shows the front panel of the LSQ1SRP1CB0.
Item
Specifications
MIPS64, 600 MHz
512 KB
64 MB
512 MB
45.1 × 377 × 355 mm (1.77 × 14.84 × 13.98 in.)
One CF card slot
One console port, used for local or remote
configuration and management of the switch through a
dialup connection
One 10/100Base-TX management Ethernet port
53 W to 60 W