1.
INSTALLATION
1.1 Power source connection........................................2
1.2 Receiver connection............................................2
1.3 Video connection...............................................2
1.4 Video display selection........................................2
1.5 Printer parallel interface.....................................3
1.6 Serial RS-232 interface........................................3
1.7 Configuring the baud rate and data format......................4
1.8 Using an external demodulator..................................4
1.9 How to install the software modules............................4
2.
OPERATING CONTROLS
2.1 Keypad functions...............................................5
2.2 LED functions..................................................5
2.3 Filter control.................................................6
2.4 Level control..................................................6
2.5 Bar-Graph display..............................................6
2.6 Weather chart transmission system..............................7
2.7 Handling of the Remote Control.................................8
3.
OPERATION AND CODE STRUCTURES
3.1 List of software 5.0 codes....................................13
3.2 Software module A.............................................13
3.3 Baud rate measurement and IAS Baud rate.......................20
3.4 Other functions...............................................21
3.5 Software module B.............................................21
3.6 Software module C.............................................24
3.7 Software module D.............................................27
3.8 Baud rate table...............................................28
4.
TECHNICAL SPECIFICATIONS
4.1 Hardware......................................................29
4.2 Software module A.............................................30
4.3 Software module B.............................................30
4.4 Software module C.............................................31
4.5 Software module D.............................................32
5.
MISCELLANEOUS
5.1 Trouble shooting..............................................33
5.2 Fuse replacement..............................................34
5.3 Signal interference...........................................34
5.4 Warranty conditions...........................................35
5.5 Sales.........................................................35
6.
ILLUSTRATION
6.1 Illustration of the processor board layout....................36
6.2 Illustration of the connector placement.......................37

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the W 4010 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wavecom W 4010

  • Page 1: Table Of Contents

    INSTALLATION 1.1 Power source connection........2 1.2 Receiver connection..........2 1.3 Video connection..........2 1.4 Video display selection........2 1.5 Printer parallel interface........3 1.6 Serial RS-232 interface........3 1.7 Configuring the baud rate and data format......4 1.8 Using an external demodulator........4 1.9 How to install the software modules......4 OPERATING CONTROLS 2.1 Keypad functions..........5 2.2 LED functions..........5...
  • Page 2: Power Source Connection

    2 to 3 Ampere output. have necessary bandwidth to give sharp and clear The W 4010 decoder has an internal text. fuse that protects not only against overcurrent, but also against wrong polarity. VIDEO DISPLAY SELECTION Choose...
  • Page 3: Serial Rs-232 Interface

    Page 3 In case of unreadable video text The RS-232 serial connector is the switch the W 4010 Off, switch On, 5 pole DIN type and the diagrams push F1 and then F3. b e l o w s h o w...
  • Page 4: Using An External Demodulator

    1200, of F1, F2, and F3 the operator can 2400, 4800, or 9600 Baud easily configure WAVECOM decoder to communicate with any RS- The number of data and stop bits 232 equipment. can be adjusted with F2 to either 7 In order to transfer the data's of level signals.
  • Page 5 PRINT When the print key is pressed, the received characters will be sent to the Centronics and RS232 serial output. POWER Switches on power of the W 4010 Function SYNCH Indicates phase selection PHASING Indicates phase selection for SITOR-ARQ system...
  • Page 6: Filter Control

    The model W 4010 has a continuously stage . cr ystal fil ter variable bandpass filter which is es p ec i all y...
  • Page 7: Weather Chart Transmission System

    Page 7 With F7-B signals look for the two signals tolerate much i n n e r t o n e s . T h e s e c a n mistuning since the tones are only recognized LEDs with apart.
  • Page 8 DOS, due to the switching of the by the PC. data lines. But the user can also write his own communication between the W 4010 occures by a firm set of software or even can steer the W commands and answers. The content 4010 from WINDOWS...
  • Page 9 Even parity Odd parity Key F4 Stationaddress 0 - 15 Key BU-ZI Store Parameters Storage of the configuration To leave this menu, switch the W 4010 off. menu “settings“ following data have programmed under TERMINAL-SETTINGS and DATA TRANSMISSION. This data have, of course, to suit to that of the W 4010.
  • Page 10 “PORTxx=ON<CR>“ the W 4010 switched If the command is not defined or to mode REMOTE. The expression “xx“ stands for the unit`s address from there is an error in it, the W 4010 “0“ to “15“. transmits sign ‘?>’.
  • Page 11 Page 11 PORTxx ON (xx is the unit’s address) MODE ARQ-E ARQ-N ARQ-M2-242 ARQ-M2-342 ARQ-M4-242 ARQ-M4-342 ARQ-N ARQ6-90 ARQ6-98 ASCII ASY-ANALYSIS AUTOSPEC BAUDOT CW-MORSE DUP-ARQ FEC-A INFO JV-FAX LEN-ANALYSIS PACKET-RADIO POL-ARQ SI-ARQ SI-FEC SITOR-AUTO SITOR-ARQ SITOR-FEC SPREAD-51 SWED-ARQ SYN-ANALYSIS WEATHER-FAX UNDEF BAUDRATE Full number in Baud, depends on the...
  • Page 12 The switching to JV-FAX must only happen in DOS. voltage range A/D- The W 4010 switches the necessary converter can be adapted to other l i n e s f o r J V - F A X t h e...
  • Page 13 Page 13 MODULE SITOR-ARQ MODULE ARQ-E SITOR-FEC ARQ-E3 BAUDOT-AUTO ARQ-N BAUDOT-VARIABLE ARQ-M2 ASCII ARQ-M2-242 CW-MORSE ARQ-M4 PACKET RADIO ARQ-M4-242 WEATHER FAX DUP-ARQ Speed Check POL-ARQ Speed Check MODULE FEC-A MODULE PRESS 300 SI-ARC BUSINESS 300 SI-FEC INFO 300 SWED-ARQ BUSINESS 50 ARQ6-90 SYNCHRONOUS ANALYSIS ARQ6-98...
  • Page 14 ISS Information Sending Station IRS Information Receiving Station The WAVECOM software always decodes the Information Sending Station. The Sitor/Amtor 7-bit alphabet uses a 3:4 mark to space ratio, however it is not identical to the alphabet No. 3. The Baud rate is always 100 Baud, i.e. 10 ms bit length.
  • Page 15 Page 15 SPEED CHECK Displays the baud rate AUTO MODE Automatic synchronization BAUDRATE SLECTOR Selects the fixed, standard Baud rates FORWARD SEQUENCE go to next operating mode F4+F3 REVERSE SEQUENCE go to previous operating mode The BAUDOT AUTO mode permits the to manually change the Baud rate.
  • Page 16 Page 16 character cases so that all of them character sets is limited, and the can be chosen. printer must also capable printing the character set. Key F2 permits choosing one of the four following character sets: ITA- Bit inversion is used as a simple Tass-Cyrillic Third Shift...
  • Page 17 Page 17 ALPHABET SELECTION Set alphabet MODE RECALL Configure new parameters MODE RECALL Restart mode FORWARD SEQUENCE go to next operating mode F4+F3 REVERSE SEQUENCE go to previous operating mode The software for the operating mode touch up the level knob, turning it MORSE been completely...
  • Page 18 American club T.A. and the other channel activity has P.R. Packet radio is a synchronous no influence on stations that are transmission. The data is usually connected together. sent as ACSII characters. WAVECOM decoder offers With packet radio information...
  • Page 19 The values of IOC and RPM must, however, manually If it is desired to print the next beforehand. picture, leave the W 4010 in the pushed again print-out AUTO MODE, which default t er m in at ed .
  • Page 20 Page 20 When the mode WEATHER-FAX is first these keys position used, the FS value is preset to picture correctly. example, 220. mode WEATHER-FAX when the left margin of the picture CALIBRATION, pushing is under the symbol <<5, push the also presets the FS value to 220.
  • Page 21 Page 21 measurement can take a very long false differences time. The keys F2 and F3 can step quartz oscillators. These false the baudrate up or down. measurement can be compensated and corrected using CONSTANT. The baudrate adjustment via keys F2 best calibration reference is the or F3 is also important for simplex FEC-A...
  • Page 22 Page 22 SPEED CHECK Displays the baud rate BAUDRATE SELECTOR Selects standard or variable Baud rates (as obtained from the F1 measurement) MODE RECALL Redisplay of the mode as well as re- synchronization FORWARD SEQUENCE go to next operating mode F4+F3 REVERSE SEQUENCE go to previous operating mode...
  • Page 23 Page 23 transmission. are full-duplex and use the same error-correcting protocoll as ARQ- The 7-bit code which is utilized division channels information transfer also divided into sub-channels which permits error recognition. usually have 28 or 56 bit periods. characters of the CCITT code no. 3 Data capture changed,...
  • Page 24 Page 24 SPEED CHECK Measure Baud rate BAUD RATE SELECTION Configure Baud rate MODE RECALL Retrieves the operating mode FORWARD SEQUENCE go to next operating mode F4+F3 REVERSE SEQUENCE go to previous operating mode The POL-ARQ is a duplex system with r e p e t i t i o n ( R Q ) c y c l e s...
  • Page 25 Baud blocks. Therefore, interference rates. The Wavecom software always causes measurement errors. receives the ISS (Information This system is similar to the Sitor Sending Station). The timing of the 2 stations looks like: five 7-bit characters transmitted...
  • Page 26 Page 26 SPEED CHECK Displays the baud rate PHASING Re-synchronisation MODE RECALL Redisplay of the mode as well as re- synchronization FORWARD SEQUENCE go to next operating mode F4+F3 REVERSE SEQUENCE go to previous operating mode length transmitted block lengths. short block blocks, the switching of the block...
  • Page 27 Page 27 SPEED CHECK Displays the baud rate BAUDRATE SELECTOR Selects Baud rates manually MODE RECALL Redisplay of the mode as well as re- synchronization FORWARD SEQUENCE go to next operating mode F4+F3 REVERSE SEQUENCE go to previous operating mode This FEC - Broadcast mode has a repetition of the first.
  • Page 28 Page 28 RTTY signals can be analyzed with there bit-slip. synchronous analysis method, stream can be stopped with the "BU- some specialized background ZI" key and written down in order knowledge is required. find certain hints clues with respect to parity, character First analyze the baud rate with distribution repetition,...
  • Page 29 Page 29 4.1 HARDWARE Case: Steel with dimensions of 200 x 250 x 80 mm, 2.5 kg Front panel: LEDs for Traffic, Sync, Phasing, Error, Idle, Rq, Input B-Y, Output A-Z, and Print On Keys for F1 / F2 / F3 / F4 On-Off / printer on-off / BU-ZI / menus Tuning LED 16 element bar graph Knob for variable filter...
  • Page 30: Software Module A

    Page 30 4.2 SOFTWARE MODULE A Baud rate check fast Baud rate determination, typically 1% error IAS Baud rate typically 0.01% error SITOR Baud rate 100 Baud automatic recognition between ARQ or FEC and SEL/COL automatic polarity recognition Automatic RQ elimination BAUDOT automatic lock-on standard + variable Baud rates from 30-300 Baud...
  • Page 31: Software Module C

    Page 31 ARQ-M2 2 division channels (1/1 mode) ARQ-M4 Baud rates: 86, 96 and 200 Baud 4 division channels (1/1 mode) Baud rates: 172 and 192 Baud rates, variable: 30 to 300 Change of division channel without data interruption automatic selection of a busy channel automatic repetition cycle recognition and RQ elimination automatic polarity recognition...
  • Page 32: Software Module D

    Page 32 ARQ6-90 Baud rate 200 Baud automatic RQ elimination and resynchronization automatic polarity recognition ARQ6-90 Baud rate 200 Baud automatic RQ elimination and resynchronization automatic polarity recognition AUTOSPEC Baud rates: 68, 102.6 and 136 Baud rate, variable: 30 to 300 Baud automatic polarity recognition SPREAD51 Baud rates: 68, 102.6 and 136...
  • Page 33 Video display is not correct Try a different monitor Check that the synch frequency is set correctly Check that the horizontal hold is set correctly Check the contrast and brightness Turn the W 4010 off - then on, press F1 then F3...
  • Page 34 (RFI), (so-called match box) can be used which radiated to transform the antenna impedance interconnecting cables. The WAVECOM to 50 Ohms. equipment is engineered to reduce this RFI to a minimum by utilizing HF cabling: RF chokes on all outputs. A metal...
  • Page 35 Page 35 Warranty WAVECOM pays for the transportation Wavecom Elektronik offers back customer, warranty months after equipment is still in warranty. date of sale. If the product was purchased from WAVECOM WAVECOM products meet the technical authorized representative and then...
  • Page 36 Page 36 1 = Module selection DIP switch 2 = Normal/inverted shift jumper; normal is the right position 3 = Internal/external demodulator; internal is the left position 4 = 2 Amp fuse 5 = Jumper selection for larger 8KB NOV-RAM 6 = Jumper selection for larger system memory of 256 kbit A - E = Software modules A through E...
  • Page 37 Page 37 COAXIAL LOW-VOLTAGE INPUT Inner conductor positive 12 to 14 Volts Outer conductor Ground (or negative polarity) 5-POLE DIN JACK 1 = serial TTL demodulator output 2 = ground 3 = serial RS-232/V.24 output 4 = external demodulator input 5 = DTR (Data Terminal Ready) input RCA JACK #1 Inner conductor:...
  • Page 38 The well-known PC-program RADIO The configuration menu becomes MANAGER for WINDOWS activated by pressing the key company SHOC supports MODUL when the W 4010 is being functions automatically. switched setting RADIO MANAGER remote possibilities shown...
  • Page 39: Hardware

    Store Parameters Storage of the configuration To leave this menu, switch the W 4010 off. In the menu “settings“ following data have to be programmed under TERMINAL- SETTINGS and DATA TRANSMISSION. This data have, of course, to suit to that of the W 4010.
  • Page 40 Each command string from the PC configuration menu. 4010 acknow ledg ed ‘C arri ag e The software of the W 4010 does Return’. The ‘Carriage Return’ not answer with an echo sign to is shown as <CR> in the above host.
  • Page 41 Page 4 PORTxx ON (xx is the unit’s address) MODE ARQ-E ARQ-E3 ARQ-M2-242 ARQ-M2-342 ARQ-M4-242 ARQ-M4-342 ARQ-N ARQ6-90 ARQ6-98 ASCII ASY-ANALYSIS AUTOSPEC BAUDOT CW-MORSE DUP-ARQ FEC-A INFO JV-FAX LEN-ANALYSIS PACKET-RADIO POL-ARQ SI-ARQ SI-FEC SITOR-AUTO SITOR-ARQ SITOR-FEC SPREAD-51 SWED-ARQ SYN-ANALYSIS WEATHER-FAX UNDEF BAUDRATE Full number in Baud, depends on the chosen...
  • Page 42 0 ... 255 = 0 ... 2.5 VOLT HINTS: • The switching to JV-FAX must only happen in DOS. The W 4010 switches the necessary lines for JV-FAX on the demodulator. This switching of the RS232-steering lines leeds to disturbances in WINDOWS.
  • Page 43 5). When this has happened, the four screws of the back side get screwed off and the panel can be taken away. (2b) Now in opposite succession the back panel can be rearranged again. Put the W 4010 with the front to you.
  • Page 44 Detach the 40-pole-cable on the CPU PCB and replace it with the enclosed 40-pole-cable (POS. 1). The 16-pole-cable has to be replaced with the enclosed 16-pole-cable (POS. A). Now the W 4010 has to be turned around, so that you have the lower side in front of you.
  • Page 45 Page 3 The video PCB has to be removed. Please return it to Wavecom. Pull the 16-pole-cable as well as the 40-pole-cable through the empty space, in which already the other cables are placed. Now attach the 16-pole-cable to the Remote Control PCB (POS.B).
  • Page 46 Page 4 16-pole-cable 40-pole-cable CPU PCB CPU PCB to Remote Control PCB to front PCB to Remote Control PCB...
  • Page 47 Page 5 (11) For the fastening of the Remote Control PCB the fastening bolts of the DSUB-plug have to be removed. (12) When the Remote Control PCB is screwed on, also the fastening bolts of the DSUB-plug can be screwed on from the outside against the back panel.
  • Page 48: Sales

    30`000 entries and the very easy excellent software of the W 4010 Radio Manager unbeaten this price offer a totally new comfort in category furthermore. operation.