Sunrise Medical Empulse R10 User Manual

Sunrise Medical Empulse R10 User Manual

Pushing device
Hide thumbs Also See for Empulse R10:

Advertisement

Quick Links

Pushing Device
R10
User's Guide
R10000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Empulse R10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sunrise Medical Empulse R10

  • Page 1 Pushing Device User’s Guide R10000...
  • Page 2 Components of the pushing device We at SUNRISE MEDICAL have been awarded the ISO-13485 certificate, which affirms the quality of our products at every stage, from R & D to production. This product complies with the standards set forth in EU and UK regulations.
  • Page 3: Table Of Contents

    17. Tyre maintenance ..........19 18. Cleaning/Hygiene ..........20 19. Disposal / Recycling of materials ......20 20. Name plate ............. 21 21. Torque ..............22 22. Technical data ............23 23. Problem solving ............ 24 Rev. A English Empulse R10...
  • Page 4: Foreword

    Sunrise Medical Australia For Sunrise Medical, it is very important that we have a 11 Daniel Street good relationship with our customers. We like to keep...
  • Page 5: Use

    3. Use 4. Area of application: The Empulse R10 is a powered pushing device, which The pushing device provides the attendant with the is attached to a wheelchair, to support the mobility and potential to enable the user to safely cover long distances integration of the wheelchair user in daily life.
  • Page 6: General Safety Notes And Driving Limits

    • wheelchair. On gradients over 8%, two tipping parts which under certain circumstances may present a supports are mandatory. choking hazard to small children. • As a beginner, you should ride particularly carefully at first. Empulse R10 English Rev. A...
  • Page 7: Safety Instructions - Prior To Each Ride

    Switch off the product immediately when it is not in use to avoid accidental operation or movements caused by accidentally touching the pushbutton. Switching off helps to preserve the battery charge. Where possible, charge the battery pack after every journey. Rev. A English Empulse R10...
  • Page 8: Warranty

    Sunrise Medical Sunrise Medical Equipment (Shanghai) Co., Ltd provides a guarantee, as set out in the warranty conditions, for * Means the Sunrise Medical facility from which the wheelchairs to its customers covering the following. product was purchased. Warranty conditions: Liability 1.
  • Page 9: Delivery

    (in the backpack). Motor controller (in the backpack). Rear Controller with holder. Charger 36V/2 A. Charger cable in compliance with local requirements (UK, Australian, China standards). Accessories including Velcro, installation tools, bolts and plastic gasket. Rev. A English Empulse R10...
  • Page 10: Docking Information

    The width is 12mm, so using or not using limit block will affect minimum installation length. 1. If the straight free space of circular tube for install docking arm is <=37MM, Suggest canceling the limit block. (Fig. 10.2) Fig. 10.2 Empulse R10 English Rev. A...
  • Page 11: Starting Up

    11. Starting up 11.1 Install the push device to the wheelchair Fig. 11.1 Step 1: Refer to “Empulse R10 Docking Information” to select the appropriate wheelchair and installation location. Step 2: Expand the Docking arm to the maximum angle, and then install the Docking arm and limit block on the wheelchair.
  • Page 12: Install Battery

    Step 1: Unfold the backpack as shown in the picture, with four buckles (T1), Adjust the straps (T2) to the required width for your wheelchair. Step 2: Secure the four buckles to the four corners of the wheelchair backrest. Empulse R10 English Rev. A...
  • Page 13: Mounting The Rear Controller Unit

    Motor controller, insert it, and tighten the nut. Step 3: Align the white arrow side of the motor connector (M) with the interface marked as M by the Motor controller, insert it and tighten the nut. Rev. A English Empulse R10...
  • Page 14: Run R10

    Please refer to the table below for specific speed limit values. Constant speed Automatic assistance Gear assistance to set limiting maximum speed maximum speed 1.5 km/h 1.5 km/h 3.0 km/h 3.0 km/h 4.5 km/h 4.5 km/h Empulse R10 English Rev. A...
  • Page 15: Charging The Batteries

    The charging You must only use the appropriate charger for this progress is not shown on the battery itself. battery from SUNRISE MEDICAL Charging temperature: 0°C to 45°C • When using the battery charger, please note the...
  • Page 16: Safety Information And Precautions On How

    • Never attempt to disassemble or modify the charger. Improper handling can lead to risks such as explosions, overheating or fire. Non-observance of the instructions for use can lead to premature wear or other defects. These instructions must be stored safely. Empulse R10 English Rev. A...
  • Page 17: Transportation

    Step 1: Loosen the rear controller interface (C) and unplug it. Fig. 13.3 Step 2: Loosen the motor interface (M) and unplug it. Fig. 13.1 Rev. A English Empulse R10...
  • Page 18: Safety

    (tears, distortions, etc.) Visual check of the wheelchair frame, the backrest tubes for damage (tears, distortions, dents, etc.) Check the tyres (profile depth, tears, damage; and replace if necessary) Check all cables and plug connections Empulse R10 English Rev. A...
  • Page 19: Frequency Of Service

    Make sure If you have any questions or require any help, please that the tyres have sufficient tread, as contact your authorized Sunrise Medical dealer. this will significantly affect the driving Depending on how much you have used your pushing characteristics.
  • Page 20: Cleaning/Hygiene

    If you need to do this quickly, you must use a liquid, alcohol based disinfectant suitable for medical products and devices. Please pay attention to the manufacturer’s instructions for the disinfectant you are using. Empulse R10 English Rev. A...
  • Page 21: Name Plate

    All pushing devices must be used in accordance with the Guangzhou ZUBU Medical Technology Co., Ltd Empulse R10 11th Floor, Building 5, No. 2 Fangda Road, XXXX-XX-XX manufacturer’s guidelines. Huangpu District, Guangzhou/China...
  • Page 22: Torque

    • Motor shaft fixing screw recommend torque 5 Nm Fig. 21.4 • The recommended torque value for connecting the rear control holder to the circular tube of the rear armrest is 3 Nm Fig. 21.5 • Fender fixing screw recommend torque 5 Nm Empulse R10 English Rev. A...
  • Page 23: Technical Data

    *The testing environment is in level 3, using the Assist button, on flat ground, with a load capacity of 115KG.Depending on the wheelchair – pushing device combination values can vary e.g. surface conditions, user weight, driving capability, add-on weight, topography. Rev. A English Empulse R10...
  • Page 24: Problem Solving

    Contact dealer to replace a motor controller E-021 Instrument communication failure and rear controller. E-025 The grip detection Contact dealer to replace the rear control. E-027 The thumb button is abnormal Contact dealer to replace the rear control. Empulse R10 English Rev. A...
  • Page 25 Rev. A English Empulse R10...
  • Page 26 Empulse R10 English Rev. A...
  • Page 27 Rev. A English Empulse R10...
  • Page 28 Sunrise Medical Equipment (Shanghai) Co., Ltd Cross Region Plaza, 899 Lingling Road, Xuhui District, Shanghai 200030 Tel.: (86) 21-644-70011 www.sunrisemedical.cn Sunrise Medical Australia 11 Daniel Street Wetherill Park NSW 2164 Australia Ph: +61 2 9678 6600 E: enquiries@sunrisemedical.com.au www.SunriseMedical.com.au Guangzhou ZUBU Medical Technology Co.,Ltd...

Table of Contents