Summary of Contents for Sunrise Medical Empulse R90
Page 1
à votre disposition en format PDF sur le site : www.SunriseMedical.com. Veuillez vous rendre à la page de votre produit pour télécharger le manuel dans la langue souhaitée, ou contactez un fournisseur agréé Sunrise Medical. P/N 252973 Rev. B...
General Manual SUNRISE MEDICAL LISTENS Thank you for choosing an Empulse R90. We want to hear your questions or com- ments about this manual, the safety and reliability of your device, and the service you receive from your Sunrise dealer. Please feel free to write or call us at the...
Please contact a Sunrise Medical authorized dealer if you have any questions regarding the use, maintenance, or safety of the device. In case there is no authorized dealer in your area or you have any questions, contact Sunrise Medical either in writing or by telephone.
Fig. 2.1 Replace or repair all illegible or damaged signs, symbols, and instructions immediately. Please contact your Fig. 2.2 Sunrise Medical authorized dealer for assistance. YYYY-MM-DD Sunrise Medical (US) LLC Fig. 2.1: Warning – Danger of fi nger entrapment (pinch point).
There are a number of sources of intense EMI in your daily environment. V/m is: Empulse R90 mounted to a Manual Wheelchair using lithium ion Some of these are obvious and easy to avoid. Others are not, and you may batteries.
fi rst practicing its operation in a safe area that is free NOTE: The Empulse R90 is designed to fi t on a variety of manual wheelchairs. For from hazards. The user must become comfortable with deactivation re- information concerning a specifi...
Be aware when making any adjustments, when The addition of the Empulse R90 to one’s wheelchair may cause it to feel diff erent. moving, and any other situation that could cause a pinch point situation.
Select a lower maximum speed indoors, on the pavement, and in pedestrian Sunrise Medical recommends replacement of the device. areas. NOTE — The warranty is void on any device that is involved in a Do not drive off...
Check after set-up and adjustment WARNING! Attachment and set-up of the R90 should be done by a Sunrise Medical authorized dealer. Improper attachment and set-up of the device onto a wheelchair may result in damage to or failure of the device, the wheelchair, or injury to the user.
Page 10
4.0 SETTING UP THE DEVICE Empulse ® ® General Manual For Folding Frame wheelchairs (Fig. 4.2 - Fig. 4.7) Fig. 4.2 Right Hand Installation Note: Folding axle adapters will be attached to camber tube but will require adjustment to center on camber tube. Note: Folding Frame wheelchairs always use small 32mm receiver clamps without inserts.
4.0 SETTING UP THE DEVICE Empulse ® ® General Manual 4.2 Wheel Up height setting (Fig. 4.8 - Fig. 4.10) Fig. 4.8 To ensure proper fi t and traction of the device, the height between the latching mechanism and the drive wheel Dim C must be properly set.
4.0 SETTING UP THE DEVICE Empulse ® ® General Manual 4.3 Attachment of the R90 to the receiver (Fig. 4.11 - Fig. 4.14) Fig. 4.11 Prior to attaching the device on to the wheelchair for the fi rst time, it must be set to the correct attachment position.
4.0 SETTING UP THE DEVICE Empulse ® ® General Manual 4.5 Charging and Attaching the Battery Fig. 4.18 For proper charging and attachment of the battery, refer to section 6.0 Battery and Charger. Top view Battery 4.6 Mounting the Control Box indicator Attach the mounting hardware onto the wheelchair frame with a 5mm allen wrench.
Unauthorized modifi cations or use of parts not supplied or approved by The App will prompt the user to agree to the R90’s Terms of Use. The user Sunrise Medical may change the function of the device. This will void the must agree to continue.
Check and adjust the settings regularly. Battery chargers are only intended to charge: Consult your Sunrise Medical authorized dealer to adjust the operational The battery supplied for the device. Do not try and charge other batteries settings immediately if you notice any change in your ability to: with the device charger.
5.0 USING THE DEVICE Empulse ® ® General Manual 5.3 Operating the control box Once paired, the R90 is ready to be driven with the control box. Engaging the To begin operation, press the actuator Wheel Up/Down button on the device wheel control box to engage the device wheel to the ground.
5.0 USING THE DEVICE Empulse ® ® General Manual 5.4 Driving the R90 Operating on an incline The device will provide assistive propulsion up an incline. It is best to WARNING! be in motion prior to encountering the incline. When using the control box, it is recommended to engage the motor Please show the utmost consideration for the other traffi...
5.0 USING THE DEVICE Empulse ® ® General Manual Gradients: ascents Gradients: descents: On descents, it is important not to let the device accelerate beyond its WARNING! normal level of ground speed. When going uphill, keep the chair moving. For steep inclines, it is recommended to power off the device. Steer by carefully pushing on either the left or right handrim making slight DANGER! left and right adjustments as you go.
WARNING! Disconnect the battery by pressing the battery release button and The battery on the Empulse R90 is not very large but stores a large amount of pulling it out of the cradle. (Fig. 6.1) charge. Improper use can cause damage or in certain circumstances lead to burns or fi...
6.0 BATTERY AND CHARGER Empulse ® ® General Manual 6.6 Lithium Ion battery WARNING! Temperature While travelling, if the internal temperature of the lithium ion battery becomes too high or too low, the battery will not provide power to the unit. The power assist function will not operate.
Device charger: Important safety instructions WARNING! The charger for the Empulse R90 is a very sensitive piece of equipment. Improper use can cause damage or in certain circumstances lead to burns or fi re. When charging always use the charger supplied.
7.0 TRANSPORTATION 7.1 Transport in a car WARNING! The battery of the Empulse R90 contains lithium-ion cells. For shipping or DANGER! transportation, you must comply with the relevant legal guidelines. The device should not be attached to the wheelchair when being transported in The guidelines for shipping lithium-ion batteries or transportation in an a car or any other moving vehicle, whether the wheelchair is transit certifi...
* Daily = Before each use of the device. Quarterly = Every three (3) months. If fasteners are found to be loose a Sunrise Medical authorized dealer should tighten the fastener to the torque setting per size detailed below, unless stated otherwise in all appropriate owner’s manuals or instruction sheets (if applicable).
8.0 MAINTENANCE AND CLEANING Empulse ® ® General Manual 8.2 Tire maintenance and replacement Fig. 8.1 Fig. 8.2 (Fig. 8.1 - Fig. 8.8) Note: This installation requires R90 Tire Replacement Tool P/N 257350 (available on Sunparts). A. Removing the tire: Use a 4mm allen wrench to loosen/remove the shroud hardware (A) for ease of disassembly.
Check that the wheel is down and engaged with the ground. Remove and reinsert the battery. Check whether the battery plugs are all securely in place. Check whether app software is up to date. If the problem has not been resolved: Contact your Sunrise Medical authorized dealer. 252973 Rev. B...
This guarantee is subject to the law of the country in which the product was nents of this device including: motor and electronic components, against purchased from Sunrise Medical. Check with your supplier to fi nd out if defects in materials and workmanship for one year from the date of fi rst international warranties apply.
12.0 TECHNICAL DATA SHEET Empulse ® ® General Manual GENERAL DATA Functions Fuse Built in short circuit protection Battery 36 V 2.5 Ah Li-Ion or 5.0 Ah Li-Ion UN test certifi cate Present Operating voltage 36 Volts CHARGER Range Up to 15.7 km (9.8 miles) or 31.4 km (19.5 miles) Input 100-120V or 220-240V AC...
Need help?
Do you have a question about the Empulse R90 and is the answer not in the manual?
Questions and answers