Cooper & Hunter CH-09MSPHCT-230VI Owner's Manual & Installation Manual

Cooper & Hunter CH-09MSPHCT-230VI Owner's Manual & Installation Manual

Four-way cassette type air conditioner
Hide thumbs Also See for CH-09MSPHCT-230VI:

Advertisement

Quick Links

Models:
CH-09MSPHCT-230VI
CH-12MSPHCT-230VI
CH-18MSPHCT-230VI
CH-N24MSPHCT-230VI
CH-N36LCCT-230VI
CH-N48LCCT-230VI

Advertisement

loading
Need help?

Need help?

Do you have a question about the CH-09MSPHCT-230VI and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cooper & Hunter CH-09MSPHCT-230VI

  • Page 1 Models: CH-09MSPHCT-230VI CH-12MSPHCT-230VI CH-18MSPHCT-230VI CH-N24MSPHCT-230VI CH-N36LCCT-230VI CH-N48LCCT-230VI...
  • Page 5 CLEANING AND MAINTENANCE WARNINGS • Turn off the device and disconnect the power before cleaning. Failure to do so can cause electrical shock. Do not clean the air conditioner with excessive amounts of water. Do not clean the air conditioner with combustible cleaning agents. Combustible cleaning agents can cause fire or deformation.
  • Page 7 Lh WARNING for Using R32/R290 Refrigerant • When flammable refrigerant are employed, appliance shall be stored in a well -ventilated area where the room size corresponds to the room area as specifiec for operation. For R32 frigerant models: Appliance shall be installed, operated and stored in a room with a floor area larger than X m •...
  • Page 8 Unit Specifications and Features Indoor unit display NOTE: Different models have different display panel. Not all the indicators describing below are available for the air conditioner you purchased. Please check the indoor display panel of the unit you purchased. Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different.
  • Page 10 Operating Conditions Use the system under the following temperatures for safe and e ective operation. If the air conditioner is used under di erent conditions, it may malfunction or become less e cient. Inverter Split Type • FOR OUTDOOR UNITS COOL mode HEAT mode DRY mode...
  • Page 11 Other features Default Setting Refrigerant Leak Detection System (some models) When the air conditioner restarts after a power In the event of a refrigerant leak, the LED failure, it will default to the factory settings DISPLAY will display refrigerant leak error code (AUTO mode, AUTO fan, 76°F (24°C).
  • Page 12 Care and Maintenance Cleaning Your Indoor Unit If using water, the inlet side should face down and away from the water stream. � BEFORE CLEANING OR • MAINTENANCE � � J � /? ALWAYS TURN OFF YOUR AIR CONDITIONER SYSTEM AND DISCONNECT ITS POWER SUPPLY �r �...
  • Page 17 Accessories The air conditioning system comes with the following accessories. Use all of the installation parts and accessories to install the air conditioner. Improper installation may result in water leakage, electrical shock and fire, or cause the equipment to fail. The items are not included with the air conditioner must be purchased separately.
  • Page 21 Indoor Unit Installation Installation Instructions - Indoor unit NOTE: Panel installation should be performedafter piping and wiring have been completed. Step 1: Select installation location DO NOT install unit in the following Before installing the indoor unit, you must locations: choose an appropriate location.
  • Page 22 Distance from ceiling relative to height of indoor unit TYPE Length of A (inch/mm) Length of H (inch/mm) Length of B (inch/mm) MODEL 18-24 8/205 > 9.3/235 9.6/245 > 10.8/275 Super-Slim 34.5/880 8/205 > 9.3/235 models 30-48 9.6/245 > 10.8/275 48-60 11.3/287 >...
  • Page 23 Step 2: Hang indoor unit 1. Use the included paper template to cut a rectangular hole in the ceiling, leaving at least 1 m (39") on all sides. The cut hole size should be 1.6"(4cm) larger than the boby size. Be sure to mark the areas where ceiling hook holes will be drilled.
  • Page 24 5. Mount the indoor unit. You will need two people to lift and secure it. Insert suspension Refrigerant piping side Drain hose side bolts into the unit' s hanging holes. Fasten them using the included washers and nuts. �ca'i'I-+ - +------- 30.3in/770mm (Suspension bolt) 34.4in/900mm (Body)
  • Page 25 NOTE FOR NEW HOME INSTALLATION When installing the unit in a new home, the NOTE: The bottom of the unit should be ceiling hooks can be embedded in advance. 0.4-0.98"(10-25mm)higher than the ceiling Make sure that the hooks do not come loose board.
  • Page 26 Indoor Drainpipe Installation CAUTION Install the drainpipe as illustrated in the following When drilling the wall hole, make sure to Figure. avoid wires, plumbing, and other sensitive Drain hose Insulation Drainpipe Metal clamp connecting port Step 4: Connect drain hose The drainpipe is used to drain water away from the unit.
  • Page 27 NOTE ON DRAINPIPE INSTALLATION • When using an extended drainpipe, tighten the indoor connection with an additional protection tube to prevent it from pulling loose. • The drainpipe should slope downward at a gradient of at least 1/100 to prevent water from flowing back into the air conditioner.
  • Page 28 Outdoor Unit Installation install unit in the following locations: Install the unit by following local codes and DO NOT regulations , there may be differ slightly (2) Near an obstacle that will block air inlets between different regions. and outlets (2) Near a public street, crowded areas, or where noise from the unit will disturb others (2) Near animals or plants that will be harmed...
  • Page 30 Page 30 ◄ ►...
  • Page 31 Refrigerant Piping Connection refrigerant enter the unit. The presence of other gases or substances will lower the unit' s capacity, and can cause abnormally high pressure in the refrigeration cycle. This can cause explosion and injury. Note on Pipe Length Ensure that the length of the refrigerant pipe, the number of bends, and the drop height between the indoor and outdoor units meets the requirements shown in the following table: LhcAu110N...
  • Page 33 PIPING EXTENSION BEYOND FLARE FORM Lh cAur10N Flare dimension (A) (Unit: in/mm) Ensure to wrap insulation around the piping. Direct contact with the bare piping may 14.2-17.2 N.m 06.4 0.3/8.3 0.3/8.3 result in burns or frostbite. (144-176 kgf.cm) 32.7-39.9 N.m •...
  • Page 34 Installation Of The Throttle. Wiring (Some Models) 19.6in BEFORE PERFORMING ANY ELECTRICAL WORK, READ THESE REGULATIONS 1. All wiring must comply with local and national electrical codes, regulations and must be installed by a licensed electrician. 2. All electrical connections must be made according to the Electrical Connection Diagram Throttle located on the panels of the indoor and outdoor...
  • Page 36 Minimum Cross-Sectional Area of Power and Signal Cables (For reference) Rated Current of Nominal Cross-Sectional Area (in/mm liance (A) 0.02in /0.75mm > 3 and ::;;6 in /0.03mm > 6 and ::;; 10 0.05in / 1.5mm > 10 and ::;; 16 0.09in /2.5mm >...
  • Page 37 Super-Slim models 3. Connect the power cable and indoor & outdoor connection cable. Clamp down the cable with the cable clamp. Control box 4. The wire groups shall be bound with cable ties and fixed on the right side plate after they are connected.
  • Page 41 Note on Adding Refrigerant Some systems require additional charging depending on pipe lengths. The standard pipe length varies according to local regulations. For example, in North America, the standard pipe length is 25' ( 7.Sm In other areas, the standard pipe length is ).
  • Page 42 Panel Installation Adjust the panel by turning it to the arrowed ihcAUTION direction so that the ceiling opening is completely covered. DO NOT place the panel facedown on the Latch floor, against a wall, or on uneven surfaces. Piping side Drain side Super-Slim models Step 1: Remove the front grille.
  • Page 44 Step 3: Install the panel Step 5: Fasten the control box lid with 2 screws . Align the front panel to the main body, taking into account the position of the piping and drain sides. Hang the four latches of the decorative panel to the hooks of the indoor unit.
  • Page 48 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version.
  • Page 49 www.cooperandhunter.us LIMITED WARRANTY STATEMENT MULTI ZONE INVERTER AIR CONDITIONING SYSTEM WITH HEAT PUMP This warranty should be registered on our website www.cooperandhunter.us within 60 days of installation The warranty is only valid when unit is installed by a Licensed HVAC Technician FOR WARRANTY SERVICE OR REPAIR: Contact your installing contractor.
  • Page 50 • Limited warranty applies only to systems that are properly installed by a state certified or licensed HVAC contractor, under applicable local and state law in accordance with all applicable building codes and permits; C&H installation and operation instructions and good trade practices. •...