SCOPREGA HYPERPUMP C Manual

Electric pump
Hide thumbs Also See for HYPERPUMP C:

Advertisement

Available languages

Available languages

H Y P E R P U M P
C
E L E C T R I C P U M P
H Y P E R P U M P C 1 2 0 V : G E 8 S 0 0 0 6
H Y P E R P U M P C 2 3 0 V : G E 8 S 0 0 0 4
ITA - ENG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HYPERPUMP C and is the answer not in the manual?

Questions and answers

Summary of Contents for SCOPREGA HYPERPUMP C

  • Page 1 H Y P E R P U M P E L E C T R I C P U M P H Y P E R P U M P C 1 2 0 V : G E 8 S 0 0 0 6 H Y P E R P U M P C 2 3 0 V : G E 8 S 0 0 0 4 ITA - ENG...
  • Page 2 Leggere queste istruzioni prima di utilizzare il gonfiatore. La mancata osservanza di tutte le istruzioni elencate di seguito può provocare danni al prodotto e/o causare lesioni gravi alle persone. Read these instructions before using the inflator. Failure to follow all of the instructions listed below may result in damage to the product and/or cause serious injury to persons.
  • Page 3 H Y P E R P U M P 0 1 . IN T RO DU ZIO N E 0 2 . D ES CRI ZI ON E F UN Z IO N A LE 0 3 . AV V ERT E N Z E PR EL IMI N A RI 0 4 .
  • Page 4 HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 H Y P E R P U M P L' H yperpu mp C è i l g onf i a tore p i ù v e rs ati le ma i re al i z z ato , c apac e...
  • Page 5 D E S C R I Z I O N E F U N Z I O N A L E HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 1 . B O C C A D I S G O N F I A G G I O 2 .
  • Page 6 4. Proteggere sempre il cavo di alimentazione. 5.Non aprire il gonfiatore. Far eseguire tutte le attività di manutenzione a manutentori qualificati autorizzati da Scoprega. La manutenzione è necessaria quando l’apparecchio risulta in qualche modo danneggiato o non funzionante. 6. Non manomettere il prodotto. L’apertura del gonfiatore comporta la decadenza della garanzia.
  • Page 7 HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 H Y P E R P U M P C PRE S S I O N E M A X : 100 0 m b a r P ORTATA M A X : 2 00 0 l / m...
  • Page 8 U T I L I Z Z I C O N S I G L I A T I HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 L' Hyp erp u m p C ra pp res e nta i l g on f iato re ideale pe r le te nde , strut ture go nf ia bili e ba rri e re g o nf i a b i l i , S UP e tut te le tipologie di go nf iabili.
  • Page 9 HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 Ca v o pre s a d i co rren te Gonf iabi le Tubo di gonf i a gg i o con controll o d i p res s i on e...
  • Page 10 U T I L I Z Z O F U N Z I O N I F U N Z I O N I HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 PER U T I LI Z Z ARE : Collega re u n est rem ità...
  • Page 11 U T I L I Z Z O F U N Z I O N I F U N Z I O N I HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 TIP OLO G I E DI UT IL IZ Z O: A seco n da a ll e nec e s si tà...
  • Page 12 U T I L I Z Z O F U N Z I O N I F U N Z I O N I HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 2 . D I S P L A Y 1 .
  • Page 13 U T I L I Z Z O F U N Z I O N I F U N Z I O N I HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 PER GON FIARE : A ccesa l a l u ce ve rde s ul tasto O N / O F F (P un to 1, Fi g 1) , i l di s p l a y most re rà...
  • Page 14 U T I L I Z Z O F U N Z I O N I F U N Z I O N I HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 GE ST I ON E SI ST EM A A .R .S : a go n fi are /s cari care e ri caric are au tom at ic am e n te.
  • Page 15 U T I L I Z Z O F U N Z I O N I F U N Z I O N I HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 GE ST I ON E DEL FLUS S O D ' ARIA :...
  • Page 16 U T I L I Z Z O F U N Z I O N I F U N Z I O N I HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 AL L ARM E DI SURRIS CAL DA ME NTO: In cas o u so p ro l u n g ato, i m otori po s so n o s urri s c al da rs i , e i l g on fi a to re e nt rerà...
  • Page 17 U T I L I Z Z O F U N Z I O N I F U N Z I O N I HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 PER S G O N FIARE : Sv itare il ta p p o s ul la bo cc a d i s go n f ia g g io ( Pu nto 4, Fi g 1) .
  • Page 18: D I S I C U R E Z Z A

    R E G O L E S I C U R E Z Z A HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 1. CO N SI DE R ARE S E MP RE L’A M BIE NT E DI L AVORO.
  • Page 19 R E G O L E S I C U R E Z Z A HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 IN STALL A Z I ON E D E L T UB O: Nella fa s e d i i nsta ll azi on e d i un tubo è imp or ta nte at tene rs i a d a l c une reg ol e .
  • Page 20 R E G O L E S I C U R E Z Z A HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 VALV PUMP VALV VALVE VALVE N. B . La l u n gh e z za d e l tu b o d e v e e s se re tal e da a s se con d are il moto e n on b iso gn a a n d a re al d i sot to d e l mi n i mo ra gg i o d i c u r va tu ra .
  • Page 21: D E I P R O B L E M I

    S O L U Z I O N E D E I P R O B L E M I HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 P R O B L E M A C A U S A...
  • Page 22 HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 Tra col l a pe r t ra sp or to Tubo Ø 40 mm per Tubo a d alta pressi on e Ridu ttore Ø 40 mm A dattato ri v al vo la...
  • Page 23 H Y P E R P U M P C H Y P E R P U M P I P 5 4 d e g r e e...
  • Page 24 H Y P E R P U M P 1. I N T RO DU CT ION 2. F U N CT I ON A L DE S CRIPT I ON 3. P RE LI MIN A RY WA RN IN GS 4.
  • Page 25 HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 H Y P E R P U M P The Hy perpu mp C i s th e m o st v ers a til e i nf l ato r e v e r ma de , c apabl e...
  • Page 26 F U N C T I O N A L D E S C R I P T I O N HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 1 . D E F L A T I O N P O R T C O N N E C T I O N 2 .
  • Page 27 4. Always protect the power cord. 5.Do not open the inflator. Have all maintenance activities performed maintenance to qualified maintenance technicians authorized by Scoprega. Maintenance is required when the unit is found to be in any way damaged or inoperative.
  • Page 28 HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 H Y P E R P U M P C MA X P RES S U RE: 1 00 0 mb a r MA X AI R F LO W: 20 00 l / m...
  • Page 29 R E C O M M E N D E D U S E S HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 Th e HY P ERP UMP C i s th e i d e a l i nf l a to r for te nts , inf latable structure s and inf lata ble ba rriers .
  • Page 30 HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 Power s o cket c ab l e Inf l atabl e Inf l ati o n h os e with pressure c ont rol...
  • Page 31: A N D F U N C T I O N S

    U S A G E A N D F U N C T I O N S HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 TO USE: Conn ect o n e end o f th e h os e to th e in f l a t i on po r t ( Poi nt 5, Fi g . 2) , a nd the other en d to th e va lve of th e i nf l ator.
  • Page 32 U S A G E A N D F U N C T I O N S HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 T YPE S O F USE : Depe n di ng o n th e in f la tio n req uire m e n ts, the us e of hos e s va ri es .
  • Page 33 U S A G E A N D F U N C T I O N S HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 2 . D I S P L A Y 1 . P R E S S U R E S E T T I N G S 3 .
  • Page 34 U S A G E A N D F U N C T I O N S HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 TO I N F L AT E : W hen th e g reen l ig ht on the O N /O F F b utton ( Poi nt 1, Fi g 1) l i g h ts up , the di s p l a y will show th e p res s ure th a t th e in f la ta bl e ha s to rea c h.
  • Page 35 U S A G E A N D F U N C T I O N S HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 A .R .S. SYST E M MANAGE M ENT: Wi th the au to mat ic cycl e ac ti v ate d ( A . R . S . - LE D s l it ), th e u ni t w i ll au to mat ic al l y T he press u re co n tro l s yste m i ns i de th e i nf l a tab l e wi th a uto ma t i c re fi l l i n g i s ch e ck th e pre ssu re of th e i nf latab le st ru ct u re .
  • Page 36: Air F Low M Anage Me Nt

    U S A G E A N D F U N C T I O N S HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 AIR F LOW M ANAGE ME NT: Once th e co n n ect io ns h a ve be en m ade a n d th e p re s s u re s et ( Pa g e 14 ), duri ng the inf l a t i o n p ha s e the i nf la to r auton omo us l y ma na g e s the f l ow of a i r to b e emit ted i nsi d e th e in f la ta bl e.
  • Page 37 U S A G E A N D F U N C T I O N S HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 OVERHEAT I N G AL AR M : In the ev ent o f p ro lo ng ed use , th e m oto rs ma y o ve rhe a t , a nd the i nf l a tor wi l l g o into lo cko u t p ha se .
  • Page 38 G E N E R A L S A F A T E Y R U L E S HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 1. ALWAYS CONSI DER TH E W ORKI NG EN VI RO NME N T.
  • Page 39 G E N E R A L S A F A T E Y R U L E S HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 HOSE I N STALL AT ION: W he n i n sta ll i n g a ho s e, it is im po r ta nt to fol l ow ce r tai n rul e s.
  • Page 40 G E N E R A L S A F A T E Y R U L E S HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 VALV PUMP VALV VALVE VALVE N. B . Th e le n g th of the h os e s h ou l d b e s u ch a s to a cc om mod ate th e m ot i on N.B.
  • Page 41 HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 P R O B L E M C A U S E S O L U T I O N Powe r su pp ly Conne ct the n o t co n n ec ted...
  • Page 42 HYPERPUMP C 120 V: GE8S0006 HYPERPUMP C 230 V: GE8S0004 S ho u l de r st ra p Ø 4 0 mm hos e for H ig h pres sure ho se for Ø 40 mm reducer Valv e fitti n gs...
  • Page 43 SCOPREGA S.P..A. Via L. Da Vinci 63 - - Cassano d’Adda (Milan) Italy 20062 Phone: + 39 036364240 Fax +39 0363 64171 info@scoprega.it www.scoprega.it...