SCOPREGA HYPERPUMP 1000 Manual

SCOPREGA HYPERPUMP 1000 Manual

Electric pump

Advertisement

Available languages

Available languages

H Y P E R P U M P
1 0 0 0
E L E C T R I C P U M P
G E 8 S 0 0 0 5
ITA - ENG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HYPERPUMP 1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for SCOPREGA HYPERPUMP 1000

  • Page 1 H Y P E R P U M P 1 0 0 0 E L E C T R I C P U M P G E 8 S 0 0 0 5 ITA - ENG...
  • Page 2 Leggere queste istruzioni prima di utilizzare il gonfiatore. La mancata osservanza di tutte le istruzioni elencate di seguito può provocare danni al prodotto e/o causare lesioni gravi alle persone. Read these instructions before using the inflator. Failure to follow all of the instructions listed below may result in damage to the product and/or cause serious injury to persons.
  • Page 3 H Y P E R P U M P 1 0 0 0 I T A 1. INTRO DU ZIO NE 2. DE SC R IZIO NE FUNZ IO N A LE 3. AV V ERTENZE PR EL IM IN A RI 4.
  • Page 4 H Y P E R P U M P 1 0 0 0 Si t ra t ta d i un g o nf i a to re a d ue stadi ad alta e f f icie nza che g a ra ntisce p re sta z i o n i e c c el l e nt i.
  • Page 5 D E S C R I Z I O N E F U N Z I O N A L E 3 . P A N N E L L O D I C O N T R O L L O 4 .
  • Page 6 4. Proteggere sempre il cavo di alimentazione. 5.Non aprire il gonfiatore. Far eseguire tutte le attività di manutenzione a manutentori qualificati autorizzati da Scoprega. La manutenzione è necessaria quando l’apparecchio risulta in qualche modo danneggiato o non funzionante. 6. Non manomettere il prodotto. L’apertura del gonfiatore comporta la decadenza della garanzia.
  • Page 7 2 3 0 V M A X P RES S U RE : 1 00 0 m ba r ( 1 4. 5 p s i ) M A X AI R FLOW : 2 000 l / m 3 5 0 m m C HARG E VO LTAG E: 230 Va c M A X C U RREN T: 20 A W E I G H T: 14 Kg...
  • Page 8 U T I L I Z Z I C O N S I G L I A T I L'HYPERP UMP 1 0 0 0 è re a l i z z a to p e r a pplic az ion i c o m e grandi st ru t tu re gonf ia b ili ch e ha nn o b i sog n o d i e ss e re go nf iate in po co te m po .
  • Page 9 G o n f i a b i l e Tu b o d i go nfi a g g i o c on c ont rol l o d i p re s si o ne Ca vo pre sa d i co rren te...
  • Page 10 U T I L I Z Z O U T I L I Z Z O F U N Z I O N I F U N Z I O N I PER UT I LI Z Z ARE : Coll eg a re u n estrem i tà...
  • Page 11 U T I L I Z Z O U T I L I Z Z O F U N Z I O N I F U N Z I O N I 2 . D I S P L A Y 1 .
  • Page 12 U T I L I Z Z O U T I L I Z Z O F U N Z I O N I F U N Z I O N I PER G ON FIARE: E s . S e s i d es id e ra u na pres si on e d i go n f iaggio di 25 0 m b ar e i l v al ore pe r A ccesa l a l u ce ve rd e sul ta sto O N /O F F ( Pu nto 1, F i g 1) , i l di sp l a y mo st re rà...
  • Page 13 U T I L I Z Z O U T I L I Z Z O F U N Z I O N I F U N Z I O N I PE R L A M ODI FI CA D E L L A PRE S SIO NE DI S CARICO: N .
  • Page 14 U T I L I Z Z O U T I L I Z Z O F U N Z I O N I F U N Z I O N I IN CAS O DI SURRIS CAL DAM E NTO : Nel ca s o u n o o en tra m b i i moto ri ra g g i u ngano o s upe rino una tem peratura di 75 °C n ell ’a ng ol o i n a lto a d estra del di sp l a y ap p a ri rà...
  • Page 15 U T I L I Z Z O U T I L I Z Z O F U N Z I O N I F U N Z I O N I PER S G ON FIARE: Coll eg a re i l t u b o al la p or ta d i sg on f iag gi o ( Pu nto 4, F i g . 1) , e p oi al l a va l v ol a dell’u n i tà...
  • Page 16 U T I L I Z Z O U T I L I Z Z O F U N Z I O N I F U N Z I O N I P ULI Z IA E MAN U T ENZ IO NE: Il go nfi a to re è...
  • Page 17: D I S I C U R E Z Z A

    R E G O L E S I C U R E Z Z A 1. ALWAYS CONS I DER TH E W ORKI NG ENV IRON ME NT. 9. WARNING! DANGER OF UNSAF E OPE R AT ION D o n ot expose th e in f lato r to ra in . D o not u se i n the p re sence of f l a m ma ble Do not mo dif y or a t temp t to repa ir the un it .
  • Page 18: D E I P R O B L E M I

    L’a p p a ra ro è Rivolgersi al centro da n n eg g i a to assistenza SCOPREGA P R O B L E M A C A U S A S O L U Z I O N E...
  • Page 19 Qu i si p os son o t rova re i divers i a cce ss ori da ab binare al gonfiatore acqu istabi li separatamen te su www. sco preg a.it:...
  • Page 20 H Y P E R P U M P 1 0 0 0 H Y P E R P U M P 1 0 0 0...
  • Page 21 H Y P E R P U M P 1 0 0 0 E N G 1. INTRODUCTION 2. FU NCTION A L DE SCR I PT IO N 3. PR EL IM IN A RY WA R NINGS 4. TE CHNICA L DATA 5.
  • Page 22 H Y P E R P U M P 1 0 0 0 I t i s a high ly ef f i c i e nt t wo- sta g e i nf lator that guarantee s exce lle nt p er form a nc e .
  • Page 23 F U N C T I O N A L D E S C R I P T I O N 3 . C O N T R O L P A N E L 4 . D E F L A T I O N P O R T C O N N E C T I O N 2 .
  • Page 24 4. Always protect the power cord. 5.Do not open the inflator. Have all maintenance activities performed maintenance to qualified maintenance technicians authorized by Scoprega. Maintenance is required when the unit is found to be in any way damaged or inoperative.
  • Page 25 2 3 0 V M A X P RES S U RE : 1 00 0 m ba r ( 1 4. 5 p s i ) M A X AI R FLOW : 2 000 l / m 3 5 0 m m C HARG E VO LTAG E: 230 Va c M A X C U RREN T: 20 A W E I G H T: 14 Kg...
  • Page 26 R E C O M M E N D E D U S E S Th e HYPE RP UMP 1 0 0 0 i s ma d e for a p p lic at ions su c h as large inf latable structures th a t n ee d to b e i nf l a te d i n a s ho r t t im e .
  • Page 27 I n f l a t a b l e Inf l a t i on ho se wi th p res su re c o ntro l Powe r s o cket c a b le...
  • Page 28: A N D F U N C T I O N S

    U S A G E A N D F U N C T I O N S TO U SE: Con nect o n e en d o f the h os e to the in f l a t i o n p o r t (Poi n t 2, Fi g . 1) , a nd the other end to th e va lve of th e i nf l ator.
  • Page 29 U S A G E A N D F U N C T I O N S 2 . D I S P L A Y 1 . P R E S S U R E S E T T I N G S 3 .
  • Page 30 U S A G E A N D F U N C T I O N S TO IN FL AT E: E . g. I f an in f lat io n pre ssu re o f 2 50 m bar i s de s ired and th e v al u e fo r re ch argi n g W hen th e g reen lig h t o n the O N / O F F b ut ton ( Poi n t 1, Fi g 1) i s l i t , th e di s pl ay i s set to 50 m bar, w h e n th e pre ssu re i n the in f l atabl e h as re ac he d 20 0 m bar will sh ow the p re s sure tha t th e i nf l atab le h as to re a ch .
  • Page 31 U S A G E A N D F U N C T I O N S TO C HAN G E T HE E XHAU ST PRE S S U RE: N . B . Up p e r L E D + lowe r L E D f l as h in g i n d i c ate th e i nf la tor is in pre ss u re P ress th e M A X b utton for 3 s ec on ds , th e d i s pl ay wi l l sta r t f l a s hi ng .
  • Page 32 U S A G E A N D F U N C T I O N S IN TH E E V EN T OF OV ERH EAT ING : If one o r both m oto rs re a c h or exc ee d a te mpe rature of 75 °C the warning ico n ( tri a n g l e w ith excl am ati on m a rk ) appe ars i n th e top ri gh t-h an d c orner of the di s p la y.
  • Page 33 U S A G E A N D F U N C T I O N S PER S G ON FIARE: Con nect th e h o se to th e de f l atio n p or t ( Poi nt 4, Fi g . 1) , a n d th en to th e v a l ve of th e i nf l a ta b le un it .
  • Page 34 U S A G E A N D F U N C T I O N S CLEAN I NG AN D MAINTE NANC E : T he in f l a to r h a s a f i lter c o m p ar tm e n t l o ca te d a t the bot tom of th e i nf l ator. It is reco m m end ed to ke ep it c lea n fo r lo ng er l i fe a n d e ffi c i en cy of th e i nf l a tor.
  • Page 35 G E N E R A L S A F A T E Y R U L E S 1. ALWAYS CONS I DER TH E W ORKI NG ENV IRON ME NT. 9. WARNING! DANGER OF UNSAF E OPE R AT ION D o n ot expose th e in f lato r to ra in .
  • Page 36: 9 R O U B L E S H O O T Ing

    P R O B L E M C A U S E S O L U T I O N Power s up p l y C on n e c t th e n o t c o n n ec te d p owe r s u p p l y T h e i n f l a to r th e O N bu tto n...
  • Page 37 H ere you ca n f ind the various a cce ss ories to g o with the inf la tor th at can be purch ased separatel y at www .sc op re ga .it:...
  • Page 38 SCOPREGA S.P..A. Via L. Da Vinci 63 - - Cassano d’Adda (Milan) Italy 20062 Phone: + 39 036364240 Fax +39 0363 64171 info@scoprega.it www.scoprega.it...

This manual is also suitable for:

Ge8s0005

Table of Contents