The Hydraloop H300 and H600 have been tested and certified according to IAPMO R&T and
NSF/ANSI 350 Class R.
SAFETY
General Safety Instructions
WARNING
Before installing or operating any Hydraloop device, carefully review this manual.
The water produced by a Hydraloop device is non-potable. DO NOT use the output water
for drinking purposes. Be aware that the backup water outlet and non-potable outlet are
situated closely.
Only Hydraloop staff, certified Hydraloop partners, or authorized installers should open or
service the device to minimize the risk of electric shock.
Follow the installation manual to ensure the safe and proper installation of the Hydraloop
device.
WARNING
If the power cable is damaged, it should be replaced by Hydraloop staff, a certified
Hydraloop partner, or authorized installers.
Before servicing or conducting maintenance, ensure the Hydraloop device is disconnected
from the backup water supply.
ATTENTION
After commissioning or performing any work on the Hydraloop device, it is essential to inspect
all water lines thoroughly for leaks and potential cross-connections.
Recommendations
ATTENTION
Install the Hydraloop device indoors, maintaining an ambient temperature range of 14-40°C
| 57-104°F.
Avoid exposing the Hydraloop device to direct sunlight.
Do not connect reusable water to a bidet and/or a toilet hand-shower.
Ensure the Hydraloop device is always easily accessible for service and maintenance.
Hydraloop Installation Manual H300 – EN - 20240805

Advertisement

loading
Need help?

Need help?

Do you have a question about the H300 2.0 and is the answer not in the manual?

Questions and answers

Summary of Contents for HYDRALOOP H300 2.0

  • Page 1 Installation Manual – Hydraloop H300 2.0 The Hydraloop H300 and H600 have been tested and certified according to IAPMO R&T and NSF/ANSI 350 Class R. SAFETY General Safety Instructions WARNING Before installing or operating any Hydraloop device, carefully review this manual.
  • Page 2 ATTENTION The Hydraloop device must be moved or transported in an upright, vertical position. • Be careful to avoid any damage to the exposed underside of the device. • RESPONSIBILITY AND LIABILITY Manufacturer Hydraloop guarantees the proper working of the device according to its general sales conditions.
  • Page 3 I case meters are installed to quantify greywater these must comply with the specifications defined in EN ISO 40064-1 and -5. The dimensions of Hydraloop devices and the distances and diameters of the connections are specified in the document “Recycle Ready Guide” provided with the system.
  • Page 4 Hydraloop Recycle Ready document. Please ensure that you have completed and submitted your Recycle Ready Checklist and that you (as the Installer) have prearranged a login for the HDM with a Hydraloop Sales Engineer prior to the installation date (support@hydraloop.com). Without this access activation cannot be performed.
  • Page 5 The Hydraloop device will be transported to your location mounted and strapped onto a HL-Transport plate, wrapped in protective packaging, and mounted onto a wooden pallet. When moving the Hydraloop device, it is important to always keep it in an • upright, vertical position. A horizontal position may cause damage to the devices’...
  • Page 6: Installation Considerations

    2. Place the Hydraloop device in the intended position. 3. Connect the H300 wastewater drain to the sewer.
  • Page 7 Simply adjust the bend plates according to its desired position. Then affix bend plates to the wall. Intake Manifold – Fall Arrest Traps Inlet manifold with inlet diverter – Anti-fall straps: Hydraloop Installation Manual H300 – EN - 20240805...
  • Page 8: Removing The Front Plate

    H300 GREY WATER INTAKE MANIFOLD INSTALLATION: 2 VERSIONS The H300 comes standard with the inlet manifold shown below. This will be installed at the factory. Inlet water sensor Inlet water sensor Ventilation valve Foam injection inlet Hydraloop Installation Manual H300 – EN - 20240805...
  • Page 9 T-piece is resting on the T1 overflow inlet shoulder. Connect the supplied 40 mm | 1 ½” shut off valve into the Hydraloop inlet manifold and connect the 40 mm | 1 ½” grey water delivery pipe into the shut off valve.
  • Page 10 Note that this third valve will not be permanently pressurized, unlike the other two reusable water outlets. This outlet’s standard function is to supply reusable water when a surplus is available. Note the outlet connections on the H300 in the drawing below: Hydraloop Installation Manual H300 – EN - 20240805...
  • Page 11 Hose supply Auxiliary 1/2" 15 mm male Connect to Output Hose (Optional) Wastewater 1 1/2" 40 mm (outer *In rubber Line diameter) sleeve – inner diameter 40 mm or adapter 40/50 Hydraloop Installation Manual H300 – EN - 20240805...
  • Page 12 PVC eccentric adapter ring or *rubber reducing sleeve (40 mm ID or 40/50) through the floor (first image) or backwards into the wall (second image). Please note that the rubber reducing sleeve do not come with the Hydraloop device and must be provided by the installer.
  • Page 13: Installation

    H300 drain line connected to sewer system through the back wall. INTRODUCING AN EXTERNAL LIFT PUMP If the Hydraloop device is on the same or higher floor as the shower/bath or washing machine an external lift pump needs to be incorporated to have the source greywater enter the device.
  • Page 14 (garden or pool) ventilation manual three-way bypass valve (not included with device) Electric inlet diverter (for washing machine grey water inlet) Hydraloop Installation Manual H300 – EN - 20240805...
  • Page 15 3. Testing, Verification and Activation: This step is conducted through the HDM by an approved and trained Installer with a pre-requested login to the HDM. Hydraloop Sales Engineers will be available for first time installers to assist and guide them through the process.
  • Page 16: Startup Time

    8. Save Changes (Save icon in top right-hand corner) Once logged into HDM you will be instructed to scan the barcode on the top of the Hydraloop device. Scanning the barcode will open your device up onto the HDM and the verification process will begin.
  • Page 17: System Malfunction

    Note: Hydraloop Systems BV is not liable for any damage if the above or any other abnormal substances enters the Hydraloop device causing the system and/or the washing machine damage.
  • Page 18 1. The Hydraloop device detects an issue with your toilets or washing machine. 2. There is an issue with the Hydraloop device, and no water can be distributed to the toilets and washing machines. In the event of a red light, please open your Hydraloop app and contact Hydraloop directly.
  • Page 19: Warranty

    Under this Factory Warranty (“Warranty”), Hydraloop guarantees to the original purchaser of the Hydraloop device (referred to as the “Product”) as outlined in Part 1 of the Warranty Policy under “Customer,” that the Product will be free from material Defects for a period of two (2) years from the date of the original purchase invoice from Hydraloop or one of its authorized Partners, unless local jurisdiction mandates a longer term.
  • Page 20: Glossary Of Terms

    This document and its contents are the sole property of Hydraloop Systems B.V. and must not be copied to a third party, either in part or whole, without the prior written consent of Hydraloop Systems B.V. Hydraloop reserves the right to change the specifications stated in this document.
  • Page 21 flushing, water for the washing machine and/or outdoor uses (irrigation, pool top-up). Start-up Time: The Hydraloop device requires a minimum of 21 days (3 weeks) or 20 showers to develop the biological treatment process in the T2 tanks and become fully operational. If the device has not sensed 20 showers by 21 days of operation, the start-up time will last longer.
  • Page 22 The Meydan Hotel, 8911 MA Leeuwarden, United States of Nad Al Sheba, Dubai, The Netherlands, America, U.A.E. +31 88 100 3500 +1 414 89 500 21 +971 5 228 457 00 E-mail: support@hydraloop.com
Website: www.hydraloop.com Hydraloop Installation Manual H300 – EN - 20240805...