Hydraloop H600
Hydraloop H600 has been tested and certified under IAPMO R&T and NSF/ANSI 350 Class R.
SAFETY
General Safety Instructions
WARNING
Before installing or operating any Hydraloop device, carefully review this manual.
The water produced by a Hydraloop device is non-potable. DO NOT use the output
water for drinking purposes. Be aware that the backup water outlet and non-potable
outlet are situated closely.
Only Hydraloop staff, certified Hydraloop partners, or authorized installers should open
or service the device to minimize the risk of electric shock.
Follow the installation manual to ensure the safe and proper installation of the
Hydraloop device.
WARNING
If the power cable is damaged, it should be replaced by Hydraloop staff, a certified
Hydraloop partner, or authorized installers.
Before servicing or conducting maintenance, ensure the Hydraloop device is
disconnected from the backup water supply.
ATTENTION
After commissioning or performing any work on the Hydraloop device, it is essential to
inspect all water lines thoroughly for leaks and potential cross-connections.
Recommendations
ATTENTION
Install the Hydraloop device indoors, maintaining an ambient temperature range of 14-
40°C | 57-104°F.
Avoid exposing the Hydraloop device to direct sunlight.
Do not connect reusable water to a bidet and/or a toilet hand-shower.
Ensure the Hydraloop device is always easily accessible for service and maintenance.
ATTENTION
The Hydraloop device must be moved or transported in an upright, vertical position.
Be careful to avoid any damage to the exposed underside of the device.
20240805 Installation Manual – Hydraloop H600
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the H600 and is the answer not in the manual?

Questions and answers

Summary of Contents for HYDRALOOP H600

  • Page 1 Installation Manual – Hydraloop H600 Hydraloop H600 has been tested and certified under IAPMO R&T and NSF/ANSI 350 Class R. SAFETY General Safety Instructions WARNING Before installing or operating any Hydraloop device, carefully review this manual. • The water produced by a Hydraloop device is non-potable. DO NOT use the output •...
  • Page 2 RESPONSIBILITY AND LIABILITY Manufacturer Hydraloop guarantees the proper working of the device according to its general sales conditions. As a manufacturer, Hydraloop is not liable in the following cases: Failure to follow instructions for Recycle Ready preparation, installation, maintenance, •...
  • Page 3 Hydraloop Recycle Ready document. Please ensure that you have completed and submitted your Recycle Ready Checklist and that you (as the Installer) have prearranged a login for the HDM with a Hydraloop Sales Engineer prior to the installation date (support@hydraloop.com). Without this access activation cannot be performed.
  • Page 4 WEIGHT WEIGHT (POUNDS) (POUNDS) H600 31.49 26.77 82.20 282.24 1630.60 H600 PACKAGED 32.28 27.76 86.22 304.29 – H600 DISPLAY 31.49 26.77 82.20 136.71 – MODEL H600 DISPLAY 32.28 27.76 86.22 158.76 – MODEL PACKAGED 20240805 Installation Manual – Hydraloop H600...
  • Page 5 The Hydraloop device will be transported to your location mounted and strapped onto a HL-Transport plate, wrapped in protective packaging, and mounted onto a wooden pallet. When moving the Hydraloop device, it is important to always keep it in an upright, vertical position. A horizontal position may cause damage to the devices’...
  • Page 6 2. Position the Hydraloop device in its planned location. 3. Connect H600 wastewater outlet to sewer. 4. Connect incoming greywater to the inlet on the top of the device via inlet manifold, in combination with external lift pump if necessary.
  • Page 7 H600 INSTALLATION ORIENTATION The H600 does not need to be affixed to the wall to protect against falling over as it is balanced with its two upper tanks having a wider base for stability. Access is needed to both the front and back of the device for maintenance, so it is recommended that it be installed with its side flush against the wall.
  • Page 8 3. T1A & T1B greywater inlet pipes 4. Overflow pipe 5. Black rubber seal rings Install the H600 inlet manifold as follows: 1. There are 3 pipes to be inserted into the top of the device and 1 open ended connection for the greywater inlet.
  • Page 9 This outlet’s standard function is to supply reusable water when a surplus is available. Note the outlet connections on the H600 in the drawing below: Connection specifications Hydraloop H300 & H600...
  • Page 10 H600 WASTEWATER OUTLET INSTALLATION The 40 mm | 1 1/2″ OD wastewater line at the bottom of the H600 needs to be connected to the sewer with the PVC eccentric adapter ring or *rubber reducing sleeve (40 mm ID or 40/50) through the floor (first image).
  • Page 11: Installation

    INSTALLATION The Installation, Verification and Activation of the Hydraloop device should only be carried out by approved installers who have prearranged for their HDM login. This can only be done through messaging support@hydraloop.com. Once you have made your appointment you will receive authorization and your login.
  • Page 12 3. Select priority options connected to toilets, washing machine, auxiliary outlet, and lift pumps 4. Activation of the H600 when all device systems have passed the validation steps. This will occur automatically once all HDM steps have been completed. 4. Commissioning: This step will be conducted through the APP, by the client, or someone assisting the client when the client is occupying the home, and permanent Wi-Fi has been established.
  • Page 13 STARTUP TIME The Hydraloop device requires a minimum of 21 days (3 weeks) and 20 showers to develop the biological treatment process in the T2 tanks and become fully operational. The greywater treatment will start from the initial start-up; however, this reusable water will be purged into the sewer and the backup water will be supplied instead.
  • Page 14: Warranty

    In the event these substances enter the H600, it can be damaged, and the water treatment can be affected. There is a function in the APP where the greywater from the T1 tank can be wasted to the sewer if you suspect foreign matter has entered the Hydraloop device (i.e., hair dye or...
  • Page 15 DATA PLATE / SERVICE LABEL The Hydraloop device has a permanent data plate attached to the top of the device that should look like the example below. This document and its contents are the sole property of Hydraloop Systems B.V. and must not be copied to a third party, either in part or whole, without the prior written consent of Hydraloop Systems B.V.
  • Page 16 Hydraloop APP: This is an APP that device owners can download on their smartphone. The APP monitors how a Hydraloop device is functioning, offers tips on how to save more water and gives encouragement when water savings in the building are at a high level. The APP will notify the owner when the 21-day Activation date (and a minimum of 20 showers/baths) has been reached and when the device is ready to distribute reusable water.
  • Page 17 This document and its contents exclusively belong to Hydraloop Systems B.V. and must not be reproduced, whether in part or in whole, without the prior written consent of Hydraloop Systems B.V. Hydraloop retains the right to modify the specifications provided in this document.

This manual is also suitable for:

H600 packagedH600 displayH600 display packaged