Executive standard: IEC 60335-2-37-2017 Freestanding Electric Open Fryer DGF-D13L/DGF-F13L INSTRUCTION MANUAL Read this manual carefully prior to use. Technology is subject to change without notice.
Page 2
Main technical parameters DGF-D13L DGF-F13L DIMENSIONS (WxDxH): 400 x 780 x 1160 mm 790 x 780 x 1160 mm CAPACITY: 2 x 13 L (11.6 L oil) 4 x 13 L (11.6 L oil) TIMER: 00:00 ~ 59:59 TEMPERATURE: 20 ~ 200°C...
SAFETY WARNING In order to ensure the user's safety and prevent personal injury, electric shock, poisoning, or fire and machine malfunction, please be sure to observe and clarify the following precautions: 1. Please read the instruction manual carefully before use, and keep it safe in case of operator change, future maintenance or other reference.
10. The waterproof level is: IPX4. Therefore, it is strictly forbidden to wash with water or flush with jet water. Otherwise, the machine will be seriously damaged, and the risk of personal injury will occur. 11. Frying temperature shall not exceed 200℃, or it would result in fire hazard and food safety problem.
6. Where children or handicapped people, people with mental illness may possibly reach. 7. Pay attention to possible pollution lead by frying. Cooker hood shall be fixed wherever fryer locates. OPERATIONAL PRECAUTIONS 1. The machine should be operated by the designated personnel to master the correct use of equipment.
3. Beware of using chemical cleaners that are suitable for use with aluminium. Corrosion can occur with many products. Particularly those containing caustic soda. Hamoki cannot accept responsibility for damage caused using corrosive cleaning products. 4. Be careful when cleaning the drainpipe and drain valve. There will be debris in the drainpipe.
Page 7
2. Proper height of oil level is expected during operation, oil level shall be in between “MIN” and “MAX” mark in the machine. CONTROL PANEL OPERATION INSTRUCTIONS CODE DESCRIPTION Heat indicator (A) When the light is on, the heating is in progress, and when the light is off, the heating is stopped.
Page 8
light on means the cleaning function is activated; when the light is off, the cleaning function is turned off. Press the P key to set the cleaning temperature and cleaning time. Oil filter key (H) Press the cleaning button repeatedly, the light on means the oil filter function is activated;...
PP0~PP9 Operating temperature Quality time (starts after work is done) PR1~PR4 Alarm time (alarm reminder, a total of 4 groups) PA1~PA4 Alarm sound selection Oil filter selection (0=do not count; 1=count) Temperature Compensation Sensitivity Temperature compensation point OFF/ON Instant heating BASIC OPERATING PROCEDURES MELTING OIL: Press the solid/liquid oil key to select, the solid oil timing window displays LI;...
Page 10
Oil filter temperature range: 120~190℃ (248~374℉) FRYING: Select any edited program group and press the timer button to start the work. When the timing is up, the timing window will display the END buzzer alarm reminder. When working in subsections, the timing window will display P0~P9, indicating the current program section.
Page 11
0~F12 S Right Basket Temperature Output Minimum 0~9.9℃ 2.0℃ Left basket temperature dead zone (valid in bit mode) Right basket temperature dead zone 0~9.9℃ 2.0℃ (valid in bit mode) INITIALISATION PARAMETERS: Press and hold the P key in the off state, the timing window will display 0000, enter the password 0008 and press the P key to enter the factory parameters.
Page 12
time. For the disassembly of oil pump, please refer to the "Oil pump diagram" section. 7. Pay attention to oil level when oil is filled, oil level filled shall be controlled in between top and bottom limit. 8. It is strictly forbidden to pump oil without oil filter paper installed. MAINTENANCE AND UPKEEP OF THE MACHINE 1.