No mixing valve will work satisfactory if improperly installed. We suggest, therefore, that you read these
instructions carefully before making the installation and follow directions as outlined. Handle the mixing
TEMPERED
A
HOT
COLD
INLET
INLET
A
HOT
INLET
General Description For 1/2" and 3/4"
Mixing Valve
This valve is two valves in one it consists of the ther-
mostatic section and pressure actuated section. The
valve is carefully assembled and tested at the factory
and set to deliver water at any desired temperature
between all cold and 105°F.
Failure of the cold water supply will:
1. Cause the pressure balancing section to react in-
stantly to restrict hot flow to thermostatic section.
2. Thermostatic element will react to shut off all hot
water.
Failure of hot supply will:
1. Have equal instantaneous reactions. When unit is
not being used, turn the handle clockwise unit flow
stops.
DIMENSIONS:
A
N.P.T.
/
1
"
2
/
3
"
4
www.lawlervalve.com
Series 9700
valve with extreme care and intelligence.
B
OUTLET
A
B
TEMPERED
OUTLET
A
COLD
INLET
PX - 9700 w/dimensions
B
N.P.T.
C
D
/
8
/
4
/
1
"
1
"
7
"
2
2
8
/
9
/
NA
3
1
"
"
4
2
NOTICE!
A
HOT
C
INLET
A
HOT
INLET
60
45
30
20
15
10
5
0.5
0.7
Caution: When maintaining and adjusting the
mixing valve, all fixtures should be isolated from
use.
Lawler Manufacturing Co., Inc. recommends
that you work safely at all times and in a manner
consistent with the OSHA Lock/Tagout standard,
29 CFR 1910.147 and other applicable standards.
(1)
Maintenance Manual
B
TEMPERED
OUTLET
A
COLD
INLET
B
TEMPERED
OUTLET
A
COLD
D
INLET
FLOW CAPACITIES - SERIES 9700
1
1.5
2
3
4
FLOW OF WATER, GALLONS PER MINUTE
Flow Capacities/S 9700
Installation &
M 9700 C
5 6
8 10
15
Need help?
Do you have a question about the 9700 Series and is the answer not in the manual?
Questions and answers