Life GE UNI RS DL Instructions And Warnings For Installation, Use And Maintenance

Control unit for two-leaf gates

Advertisement

GE UNI R DL
V.1
GE UNI RS DL
GE UNIR DL
CONTROL UNIT FOR TWO-LEAF GATES
INSTRUCTIONS AND WARNINGS FOR INSTALLATION, USE AND MAINTENANCE
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GE UNI RS DL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Life GE UNI RS DL

  • Page 1 GE UNI R DL GE UNI RS DL GE UNIR DL CONTROL UNIT FOR TWO-LEAF GATES INSTRUCTIONS AND WARNINGS FOR INSTALLATION, USE AND MAINTENANCE Page 1...
  • Page 2: Standard Installation

    STANDARD INSTALLATION Tab. 1: Components and devices of a typical GE UNI R DL automation. Energy Saving In order to save energy, we have introduced the function To optimize energy consumption, we have introduced the Energy Saving function. After 10 minutes from the control unit setup, the front Energy Saving.
  • Page 3 GEBOX ASSEMBLY INSTRUCTIONS. Page 3...
  • Page 4 List of electric cables The cables needed may vary depending on the installation and type and quantity of devices installed. The cables used in the installation must be IEC 60335 compliant. Pos. Connection Type of cable Electricity supply line 3x1,5 mm cable Power supply Flashing light...
  • Page 5 GE UNI R DL AERIAL RG58-50ohm COMMON COMMANDS N.C. PEDESTRIAN N.O. N.O. N.O. STEP For PHOTO and PHOTO1 N.C. PHOTO1 input functions N.C. PHOTO see page 7 12 Vac 15VA ELECTRIC LOCK 24 Vac 3W max INDICATOR LIGHT OUTPUT 24 Vac 200 mA max MOTOR2 OPEN CAPACITOR COMMON MOTOR2...
  • Page 6 PROGRAMMING THE CONTROL BOARD CONTROL UNIT SETUP STOP PLATES Ensure that the open and close stop plates are set to the correct position PROGRAMMING THE CONTROL UNIT LIMIT SWITCHES Make sure you have fixed the mechanical opening and closing limit switches of the automation. SINGLE MOTOR - In the case of a single gate installation connect the motor into terminals 20-21-22 SINGLE MOTOR...
  • Page 7 RADIO CONTROL MANAGEMENT REMOVE AN EXISTING REMOTE TRANSMITTER. The control unit is fitted with a built-in radio receiver with a 1 channel 1000-code memory, with a 433.92 MHz frequency with LIFE Rolling Code and Auto code encoding. Resetting an initialised radio control...
  • Page 8: Options Setting

    PROGRAMMING MENUS PROGRAMMING MENUS AUTOMATIC CLOSING AUTOMATIC CLOSING 3.1.2 Automatic reclosure OPTIONS SETTING In this mode by pressing the start button or In this mode by pressing the start button or Automatic reclosure is activated after a preset PAUSE TIME. radio transmitter the automation changes it radio transmitter the automation changes it AUTOMATIC CLOSURE...
  • Page 9 • • Press the force button (bottom left) and the Press the force button (bottom left) and the FORCE FORCE left red led switches on. left red led switches on. 3.2.3 Force - Press the force button (bottom left), the red led comes on. •...
  • Page 10: Manual Programming

    MANUAL PROGRAMMING 3.3.4 Programming Manual POSITION THE GATE AT 45 DEGREES POSITION THE GATE AT 45 DEGREES PLACE THE LEAVES AT 45° Position the leaf gates at 45° Hold the START button for 5 seconds, the 5 LEDs first light •...
  • Page 11: General Information

    SAFETY INSTRUCTIONS AND WARNINGS chapter. With the aim of improving its products, LIFE home integration reserves the right to bring about alterations to them at any time, without giving prior notice. This document conforms to the state of the automation at which it is provided when released for sale.
  • Page 12: First Usage

    TESTING AND TRIAL RUN • The testing and trial run must be performed by a COMPETENT PERSON supervised and aided by a PROFESSIONAL FITTER. It is the responsibility of the person who tests and sets up the automation (of which the control unit is a part) to perform the checks required in accordance with the risks existing and to check conformity with the relevant legislation and standards, in particular with EN standard 12445, which governs the methods for performing trials on gate automations and EN standard 12453 that specifies the performance requisites concerning safety of use.
  • Page 13: Routine Maintenance

    MAINTENANCE 10.1 Maintenance instructions and warnings • Once the automation has been tested, the parameters set must not be altered. If further adjustments (e.g. alterations to the voltage value) are made, ALL THE CHECKS REQUIRED FOR TESTING AND COMPLIANCE WITH STANDARDS MUST BE REPEATED. •...
  • Page 14: Declaration Of Conformity

    Declaration of conformity under Directive 98/37/EC, appendix II, part B (Manufacturer’s Declaration of CE Conformity) LIFE Home Integration Via S.Pertini 3/5 31014 COLLE UMBERTO (TV) declares that the following product: GEUNIR DL control unit satisfies the essential requisites established in the following directives: •...
  • Page 15: Instruction Issue

    Address: Via Sandro Pertini,3/5 31014 COLLE UMBERTO (TV) Italia Telephone: + 39 0438 388592 Telefax: + 39 0438 388593 http www.homelife.it Instruction issue V.1 e-mail: info@homelife.it Page 15...