Life GE UNI 24R Instructions And Warnings For Installation, Use And Maintenance

Control unit for two-leaf gates
Table of Contents

Advertisement

GE UNI24R
CENTRALE DI COMANDO PER CANCELLI A DUE ANTE
CONTROL UNIT FOR TWO-LEAF GATES
STEUERUNG FÜR ZWEIFLÜGELTORE
ISTRUZIONI E AVVERTENZE PER L`INSTALLAZIONE, L`USO E LA MANUTENZIONE
INSTRUCTIONS AND WARNINGS FOR INSTALLATION, USE AND MAINTENANCE
WARTUNGSVORSCHRIFTEN UND HINWEISE
VERSIONE 3DP0510000 REV 10/2008
A COPERT. GE UNI24R (IT-GB-D) Tre.indd 3
31-10-2008 11:16:42

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GE UNI 24R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Life GE UNI 24R

  • Page 1 GE UNI24R CENTRALE DI COMANDO PER CANCELLI A DUE ANTE CONTROL UNIT FOR TWO-LEAF GATES STEUERUNG FÜR ZWEIFLÜGELTORE ISTRUZIONI E AVVERTENZE PER L`INSTALLAZIONE, L`USO E LA MANUTENZIONE INSTRUCTIONS AND WARNINGS FOR INSTALLATION, USE AND MAINTENANCE WARTUNGSVORSCHRIFTEN UND HINWEISE VERSIONE 3DP0510000 REV 10/2008 A COPERT.
  • Page 2 OP0020A Tab. 2: Descrizione contenuto scatola centralina GE UNI 24R. Tab. 2: Description of the content of a GE UNI 24R control unit pack. Tab. 2: Beschreibung des Inhaltes einer GE UNI 24R Verpackungseinheit. A COPERT. GE UNI24R (IT-GB-D) Tre.indd 1...
  • Page 3 IMPIANTO ELETTRICO ELECTRICAL SYSTEM ELECTRICAL SYSTEM AERIAL RG68-50ohm COMMANDS COMMON N.C. STOP PEDONAL N.O. OPEN N.O. CLOSE N.O. STEP N.C. PHOTO 24 Vdc 3W max INDICATOR LIGHT 12 Vdc 15VA ELECTRIC LOCK 24 Vdc 25W max FLASHING 24 Vdc 15W max COUTESY LYGHT OUTPUT 30 Vdc...
  • Page 4 ISTRUZIONE DI MONTAGGIO. GEBOX. GEBOX ASSEMBLY INSTRUCTIONS. GEBOX ASSEMBLY INSTRUCTIONS A COPERT. GE UNI24R (IT-GB-D) Tre.indd 4 31-10-2008 11:16:45...
  • Page 5: Table Of Contents

    CONTROL UNIT FOR TWO-LEAF GATES GE UNI24R INSTRUCTIONS AND WARNINGS FOR INSTALLATION, USE AND MAINTENANCE MANUAL DESTINED FOR USE BY PROFESSIONAL FITTERS ONLY INDEX QUICK INSTALLATION OF LIGHTWEIGHT 3.3.4 Photo test GATE WITH 90° OPENING 3.3.5 Photo 1 STANDARD INSTALLATION 3.3.6 Close after photo 3.3.7...
  • Page 6: Quick Installation Of Lightweight Gate With 90° Opening

    QUICK INSTALLATION OF LIGHTWEIGHT GATE WITH 90° OPENING PHASE STOP PLATE ADJUSTMENT Release the operator. Adjust the opening (A) and closure (B) stop plates. 45° Position the leafs at 45° Relock the LOCK UNLOCK PHASE 2 Switch on the system’s power supply and check that the two red LEDs flash.
  • Page 7 EL0013 PHASE 4 CARD INITIALISATION EL0021a1 EL0028 EL0013 EL0015 EL0020 a) Switch off power supply. b) Simultaneously press and hold down switch on the power supply to the system to light the third LED. c) Release keys , the two red LEDs will now flash.
  • Page 8: Standard Installation

    STANDARD INSTALLATION PHASE 1 STOP PLATE ADJUSTMENT a) Release the operator. b) Adjust the opening (A) and closure (B) stop plates. 45° c) Position the leafs at 45° d) Relock the operator. LOCK UNLOCK PHASE 2 Switch on the system’s power supply and check that the two red LEDs flash.
  • Page 9 EL0013 PHASE 4 EL0021a1 EL0028 CARD INITIALISATION EL0013 EL0015 EL0020 a) Switch off power supply. b) Simultaneously press and hold down and switch on the power supply to the system to light the third LED. c) Release keys , the two red LEDs will now flash.
  • Page 10 EL0012 EL006f EL009 PHASE 7 IDENTIFICATION OF CLOSURE STAGGERING. EL0021c EL0012 EL009 EL006f a) Give the step command (A) and release, the leaf (2) will close. EL0016 EL0016 When it reaches the point at which one also wishes to close leaf (1) (closure staggering) give the step command (A) and release: leaf (1) will also close.
  • Page 11: Wiring And Connections

    1 WIRING AND CONNECTIONS • Before commencing wiring and connection work, read the SAFETY INDICATIONS AND WARNINGS and INSTRUCTIONS AND INDICATIONS FOR INSTALLATION Chapters thoroughly. • All wiring and connection operations must be carried out with the control unit disconnected from the electricity supply (and from the buffer battery if present);...
  • Page 12: Wiring Diagram Of The Right Hand Side Of The Control Unit

    1.7.1 Wiring diagram of the right hand side of the control unit Fig. 7 shows a diagram of the connection terminals for the aerial, various controls and the various power supplies (indicator light, electrolock, flashing light, courtesy light, photocells, selectors, etc.). . These are the vertical terminals positioned on the right hand side of the control unit and numbered from 1 to 19. Terminals Description (see wiring diagram on page 2A) 1 - 2 Aerial: aerial cable input 1 sheath, 2 cables. Use a RG58- 50ohm cable Common: for stop, open, close, step and photo inputs. 6 - 7 STOP*: programmable NC input, commands gate stoppage. Can be connected to safety devices such as an emergency stop button. When the command is released automatic closure never occurs and a new movement command must be given.
  • Page 13: Indicator Leds

    1.7.3 Indicator LEDs There is a row of 5 LEDs on the right hand side of the board, under the terminals. These LEDs are lit when the corresponding signal is present. For the NC inputs, stop and photo, the corresponding LEDs L7 and L11 are normally lit; for the NO inputs open, close and step, the corresponding LEDS L8, L9 and L10 are normally off. These LEDs therefore indicate any malfunction of the connected devices. STARTING UP 2.1 Description of the keyboard The keyboard on the control unit makes it possible to set all the functions necessary for a safe and controlled functioning of the automation.
  • Page 14: Radio Control Identification

    2.2 Radio control identification The control unit is fitted with a built-in radio receiver with a 1000 code memory and 2 channels with a 433.92 MHz frequency with LIFE Rolling Code and Auto code encoding. 2.2.1 STEP command identification 1) Press...
  • Page 15: Resetting All Identified Radio Controls

    EL0014G EL0014H 2.2.4 Resetting all identified radio controls EL0043A 1) Press on the control unit twice, the two right LEDs and the two left LEDs will flash alternately whilst EL0023a EL0022a EL0028 EL0029 the SPLENDOR flashing light emits a triple flash. EL0014G EL0014H 2) Simultaneously press , check the alternate flashing of the red LED EL0018 EL0043A 3) Wait until the LEDs switch off. 4) To exit identification, wait approximately 15 seconds EL0018 EL0018...
  • Page 16: Initialisation

    ATTENTION: Each phase has a timed exit (after approx.15 secs.) from receiver programming feature. 2.3 INITIALISATION ATTENTION: LIFE cards are multipurpose and may be used for several applications; therefore, on activation they require the identi- fication of the type of automation that they will serve.
  • Page 17: Single Leaf Gate

    • During the movement of leaf 2 the lateral LEDs on the right-hand side will flash alternately. 2.3.1.2 Single leaf gate There are two initial programming modes available: ‘ONE TOUCH’: automatic programming in which the various operations are performed automatically with default settings established by LIFE. This mode is recommended for lightweight leafs and openings of up to 90°. STANDARD: the initial manoeuvres are controlled by the fitter. A) SINGLE LEAF ‘ONE TOUCH’ PROGRAMMING Press , the red LED on the right-hand side will remain lit.
  • Page 18: Adjustments

    EL0013 ADJUSTMENTS EL0028a EL0028 3.1.1 Card initialisation All the values previously stored on the card are erased and the automation is defined. EL0013 EL0013 EL0018 EL0020 Switch off power voltage. Simultaneously press and hold down switch the power supply back on. EL0013 After a few seconds the led will light: EL0018 EL0020 Release keys , the two red LEDs will now EL0018 EL0020...
  • Page 19: Semi-Automatic

    3.2.2 Semi-automatic EL0028 EL0024b Automatic re-closure is not enabled. In this mode, by pressing the ‘step’ key on the remote control the gate changes its motion according to the sequence 1 – OPEN 2 – STOP 3 – CLOSE 4 – STOP; for example, if the gate is opening and one selects the step command on the remote control, the gate stops; conversely, if the gate is closed, when the command is given it opens.
  • Page 20: Condominium

    EL0028 EL0038 3.2.6 Condominium Automatic closure is enabled. The gate closes automatically after the period set in the PAUSE TIME function. EL0021b2 The ‘step’ command only works as an opening command. The CLOSE command is only enabled when the gate is fully open. EL0018 EL0018 EL0018...
  • Page 21: Close After Photo

    3.3.5 Photo 1 EL0024b EL0028 This function makes it possible to set for the inputs to the terminals 6 - 7 and 6 – 11 one of the following functions: PHOTO, PHOTO1, PHOTO2, STOP AND PAUSE. Press followed by PHOTO 1: EL0018 if green LED (DX) is lit: programming outputs 6-7.
  • Page 22: Force

    3.3.8 Force function regulates the thrust and therefore the speed of the automation. EL0013F The total force is obtained by adding two components: EL0014a EL0038 EL0028 BASE FORCE + DYNAMIC FORCE = TOTAL FORCE The BASIC FORCE is a constant component over all phases. The DYNAMIC FORCE is an independently adjustable component over the four OPENING, DECELERATION IN OPENING, CLOSURE, EL0014b DECELERATION IN CLOSURE phases and on the two leafs.
  • Page 23: Deceleration In Opening And Closure

    EL0028 EL0028 3.3.11 Deceleration in opening and closure. This function regulates the distance travelled by the gate in deceleration in the final stretches of opening and closure. EL0018 EL0018 To set DECELERATION IN OPENING press followed by EL0014a EL0038 EL0038 To set DECELERATION IN CLOSING press EL0014b followed by EL0014c The various distances are set by pressing EL0018 The minimum deceleration value is 4% of total travel.
  • Page 24: Fuses

    Fuses 3.4.1 External fuse The external fuse is located on the main 230 volt power supply, protecting against transformer overload. Technical features: miniature fuse 5x20 T3,15A, IEC 60127 or EN 60127 certified. 3.4.2 Card fuses There are two internal fuses applied to the card: the first F1 protects the electronic card power supply; the second F2 protects the motor and auxilia- ries’ power supply. • Technical features F1: miniature fuse 5x20 T1A, IEC 60127 or EN 60127 certified. • Technical features F2: miniature fuse 5x20 T10A, IEC 60127 or EN 60127 certified. N.B. no intervention is authorised on the two card fuses. Preset functions F1 & F2 It is possible to select two standard function parameter settings. To enable them: 1 .Press 2.
  • Page 25: Buffer Batteries (Optional)

    BUFFER BATTERIES (OPTIONAL) a) In the GE UNI 24 R control unit it is possible to install a pair of 12 V 2Ah buffer batteries (AGE 12) (optional), which allows emergency operation in the event of a power failure. b) The batteries must be installed and replaced at the end of their service life by a PROFESSIONAL FITTER and not by the user, as there are live parts close by. c) The control unit is designed to house an AGECH battery charger, which automatically charges the connected pair of batteries. EL0021c1 In the event of power failure, the automation operates in a partial way for a certain number of actions. The gate switches into “DEAD MAN” mode (persistent commands) automatically.
  • Page 26: Automation Use

    SAFETY INSTRUCTIONS AND WARNINGS chapter. With the aim of improving its products, LIFE home integration reserves the right to bring about alterations to them at any time, without giving prior notice. This document conforms to the state of the automation at which it is provided when released for sale.
  • Page 27: Safety Instructions And Warnings

    • Ensure that the individual devices to be installed are compatible with GE UNI 24R control unit, paying careful attention to the points raised in the TECHNICAL DATA chapter. Do not proceed if even just one device is unsuitable for the intended use.
  • Page 28: First Usage

    10.2 First Usage The automation may only be used for the first time once all the checks described in the TESTING chapter have been performed successfully. The automation may not be used in precarious or tempo- rary conditions. a) Compile a technical file for the automation, which must include at least: • a general mechanical and electrical diagram, • risk analysis and solutions adopted for eliminating or reducing risks, • manuals of the individual components, • list of the components used, • instructions for use and warnings concerning use by the owner, • system maintenance record • declaration of the system’s CE conformity b) Fix a CE marking plate to the gate, bearing at least the following information: • Name and address of the party responsible for installation and testing; • Type of automation; • Model; • Registration number; • Year of installation • CE mark c) Fill in the declaration of conformity and give it to the owner of the automation. d) Compile the guide with the instruction manual (EN 12635 p. 5.3 and 5.4) and give it to the owner of the automation. e) Compile the maintenance and improvement log (EN 12635 p.5.3) and give it to the owner of the automation. f) Compile the guide containing the instructions for maintenance that provides instructions concerning the maintenance of all automation devices (EN 12635 p. 5.3 and 5.5) and give it to the owner of the automation. g) Before the first use of the automation, the owner must have been given adequate information concerning hazards and residual risks. SAFETY INSTRUCTIONS AND WARNINGS 11.1 Indications and warnings for use • It is the fitter’s duty to perform risk analysis and inform the user/owner of any existing residual risks.
  • Page 29: Manufacturer's Declaration Of Conformity

    14 MANUFACTURER’S DECLARATION OF CONFORMITY Declaration of conformity under Directive 98/37/EC, appendix II, part B (Manufacturer’s Declaration of CE Conformity). LIFE home integration Via 1 Maggio, 37 31043 FONTANELLE (TV) – Italy declares that the following product: GE UNI 24R control unit satisfies the essential requisites established in the following directives: • Low voltage directive 73/23/EEC and subsequent amendments, • Electromagnetic compatibility directive 89/336/EEC and subsequent amendments, • Radio and telecommunications equipment directive 1999/5/EC and subsequent amendments. and satisfies the following standards: •...
  • Page 30 NOTES 2 MAN.ISTRUZ.GE UNI24R (GB).indd 26 30-10-2008 16:42:09...