Emergency Operation; Test Operation - Haier HSU-09LE04 - annexe 1 Operation Manual

Split type room air conditioner
Hide thumbs Also See for HSU-09LE04 - annexe 1:
Table of Contents

Advertisement

Operation
Emergency operation and test operation

Emergency Operation:

Use this operation only when the remote controller is defective or lost.
When the emergency operation switch is pressed, the " Pi "sound is
heard once, which means the start of this operation.
In this operation, the system automatically selects the operation
modes, cooling or heating, according to the room temperature:
Room
temperature
o
ABOVE 23
C
o
BELOW 23
C
It is impossible to change the settings of temp.and air flow
speed,It is also not possible to operate in timer or dry mode.

Test operation:

Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room
temperature is below 16
normal operation.
Continue to press the test operation switch for more
than 5 seconds. After you hear the "Pi" sound twice,
release your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
After 30 minutes, test operation ends automatically.
Removal of the restriction of emergency or test operation:
Press the emergency operation switch once more, or manipulate through the
remote controller; the "Pi" sound, the emergency or test operation is terminated.
When the remote controller is manipulated, it gets the system back to the
normal operation mode.
Timer
Designated
mode
temperature
NO
o
26
C
o
23
C
NO
o
C, do not use it in the
Air flow
Operation
speed
mode
AUTO
COOLING
AUTO
HEATING
12
Pi
Pi Pi