Operation; Emergency Operation; Test Operation - Haier HSU-09LEK03/R2(DB) Operation Manual

Hide thumbs Also See for HSU-09LEK03/R2(DB):
Table of Contents

Advertisement

Operation

Base Operation
Remote controller
1.Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select temp.setting
/
Press
Every time the button is pressed,
temp.setting increase 1 C,if kept
depressed, it will increase rapidly
Every time the button is pressed,
temp.setting decrease 1 C,if kept
depressed, it will decrease rapidly
Select a desired temperature.
3.Fan function
Press FAN button
For each press
button fan speed
changes as follows:
Remote controller:
LOW
MED
HI
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to
room temperature.
Remote
Operation
Mode
Controller
Under the mode of auto operation, air conditioner will
automatically select Cool operation according to room
AUTO
temperature. When FAN is set to AUTO the air conditioner
automatically adjusts the fan speed according to room
temperature.
COOL
In DRY mode , when room temperature becomes lower
DRY
than temp.setting+2
speed regardless of FAN setting.
In FAN operation mode , the unit will not operate in COOL or
HEAT mode but only in FAN mode, AUTO is not available in
FAN
FAN mode. And temp. setting is disabled. In FAN mode,
sleep operation is not available.
1
3
2
2
button
o
o
Display
circulated
AUTO
Note
o
C, unit will run intermittently at LOW
Emergency operation and test operation

Emergency Operation:

Use this operation only when the remote
controller is defective or lost.
When the emergency operation switch is
pressed,the" Pi "sound is heard once, which
means
the start of this operation.
In this operation, the system automatically
selects the operation modes,cooling or fan
or heat, according to the room temperature.
Room
Operation
mode
temperature
ABOVE 23
O
C
COOLING
(cooling only uint)
Operation
mode
Room temperature
BELOW 23
C
FAN
O
It is not possible to operate in dry mode.

Test operation:

Test ope ration switch is the same as emergency switch.
Use this switch in the test operation when the room
o
below 16
C, do not use it in the normal operation.
Continue to press the test operation
switch for more than 5 seconds.After
you hear the "Pi" sound twice, release
your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
Air Flow Direction Adjustment
1.Status display of air flow
Press
button to enter additional options, when cycle
display to
,
will flash.And then press
up and down air flow function.
Press
button. For each press,changes as follows:
Remote controller:
COOL/DRY:
Initial state
2.Left and right air flow adjustment (manual)
Move the vertical blade by a knob on air conditioner to adjust
left and right direction referring to Fig.
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur at
air outlet if all vertical louvers are adjusted to left or right.
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY mode,otherwise,
condensate water might occur.
Note:
When restart after remote turning off, the remote controller
will automatically return to the previous set swing position.
Designated
Timer
Air flow
mode
temperature
AUTOMATIC
26
O
C
NO
Designated
Timer
Air flow
temperature
mode
AUTOMATIC
26
O
C
NO
temperature is
3D
enter to

Advertisement