Emergency Operation; Test Operation - Haier AS09PBDHRA Operation Manual

Split type room air conditioner
Hide thumbs Also See for AS09PBDHRA:
Table of Contents

Advertisement

Operation
• Timer On/Off On-Off Operation
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:
--i
......................
O N - O FF ,
ON - O FF
••••••••••••••••••••••
0.5h
0.5h
0.5h
TIMER ON TIMER OFF
TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or
TIMER OFF or TIMER ON-OFF). " ON "or " OFF "will flash.
T / A
3.Press
button to set time.
A
Press the button for each time, setting time in the first
12 hours increased by 0.5 hour every time, after 12
hours.increased by 1 hour every time.
T
Press the button for each time, settiing time in the first
12 hours decreased by 0.5 hour every time, after 12
hours,decreased by 1 hour every time.
It can be adjusted within 24 hours.
4.Confirm timer setting
After adjust the time,press
time ON or OFF button will not flash any more.
5.Cancel timer setting
Press the
button by times until the time display
eliminated.
Hints:
After replacing batteries or a power failure happens, time
setting should be reset.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be achieved.
• Self Clean Operation
+Functional description: the purpose of this function is to
clean the evaporator and condenser.
枉ntry and exit, Press self clean button to enter this
function, then it will display "CL" on the panel of the indoor
unit and also on the remote controller. After running 20-30
minutes, this function will exit automatically when the " Pi "
sound is heard twice, then the unit returns to original state.
Under operation process of self clean, pressing the button
repeatedly has no effect and the function will not exit, but
pressing the power off button and other mode button can
make it exit.
__.i
--....一一一一....一一一一..
OFF - ON i- BLANK
• 一..一.........一一一一...
0.5h
TIMER OFF-ON
歪量
button and confirm the
• POWER/SOFT Operation
(1)
POWER Operation
When you need rapid heating or cooling, you can use this function.
巨已
Press
button to enter additional options, when cycle
display to�.� 习will flash, and then press陲墨,enter to
power function. When cancel the function, please enter
additional options again and to cancel power function.
QUI ET Operation
(2)
You can use this function when silence is needed for rest or reading.
Press QUIET button, the remote controller will show飞:J),
and then achieve to the quiet function. Press again this
QUIET button , the quiet function will be cancelled.
Note:
During POWER operation, in rapid COOL mode , the room
will show inhomogeneous temperature distribution.
Long period QUIET operation will cause effect of not too
cool or not too warm.
• Emergency operation and test operation

Emergency Operation:

• Use this operation only when the remote controller
is defective or lost.
• When the emergency operation switch is
pressed.the" Pi "sound is heard once, which means
the start of this operation
Room
Operation Designated
mode
temperature mode
temperature
ABOVE 23
C COOLI N G
26
C
°
°
BELOW23
HEAT
23
c
°
(Cooling only ui n t)
Operati o n
Room temperature
mode
BELOW23
FAN
• It is not possible to operate in dry mode

Test operation:

Test operation switch is the same as emergency switch.
• Use this switch in the test operation when the room temperature is below
16·c, do not use it in the normal operation.
• Continue to press the test operation switch for more
than 5 seconds. After you hear the "Pi" sound twice,
release your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
• After 30 minutes, test operation ends automatically.
Timer
NO
NO
26