Haier HPU-18CRA13 - annexe 1 Operation Manual
Haier HPU-18CRA13 - annexe 1 Operation Manual

Haier HPU-18CRA13 - annexe 1 Operation Manual

Hide thumbs Also See for HPU-18CRA13 - annexe 1:

Advertisement

llation Manual of Room Air Conditioner
Necessary Tools for Installation
w
e drill
(17,19 and 26mm)
OPERATION MANUAL
parts
Number
parts
of
articles
1
ntroller
2
ry battery
Optional parts for piping
Mark
1
A
ting plate
B
1
C
Saddle(L.S) with screws
ain hose
Connecting electric cable
D
for indoor and outdoor
4
E
astic cap
F
Heating insulating material
1
-elbow
G
4
hion
1
rting plate
1
ng cable
Please read this operation manual before using the air conditioner
No.0010513341
The marks from
The distance between the indoor unit and the floor should be
more than 2m.
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
PACKAGED UNIT
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
Drawing for the installation of indoor and outdoor units
The models adopt HFC free refrigerant R410A
Parts name
Non-adhesive tape
Adhesive tape
HPU-18CRA13
HPU-20CRA13
Drain hose
Piping hole cover
Arrangement of piping directions
Rear left
Rear
Left
right
Right
Below
A
to
G
in the figure are the parts numbers.
9.Nipper
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Attention must be paid to
the rising up of drain hose
12.Reamer

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HPU-18CRA13 - annexe 1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Haier HPU-18CRA13 - annexe 1

  • Page 1 Rear Left right Right Below Please read this operation manual before using the air conditioner No.0010513341 The marks from in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m.
  • Page 2: Safety Instructions And Warnings

    Before starting the air conditioner, read the Before disposing an old air conditioner that information given in the User's Guide caref- goes out of use, please make sure it's inop- ully. The User's Guide contains very impor- erative and safe. Unplug the air conditioner tant observations relating to the assembly, in order to avoid the risk of child entrapment.
  • Page 3: Specifications

    3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. 4. The wiring method should be in line with the local wiring standard.
  • Page 4: Safety Instruction

    Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. lnstallation in a inadequate place may cause accidents. Do not install in the following place. CAUTION Do not install in the...
  • Page 5 PROHIBITION PROHIBITION CAUTION Take fresh air occasionally especially Do not operate the switch with Do not use for the purpose of storage of food, art work, precise equipment, when gas appliance is running at the wet hand. breeding, or cultivation.
  • Page 6: Parts And Functions

    Parts and Functions Indoor unit PUSH AUTO ON/OFF AIR FLOW MODE HEALTH TEMP+ TEMP- Remote controller box Before operating the unit,please press “PUSH” area to take out the remote controller. Anion generator (inside) Outlet Control board Inlet grille Inlet Air filter(inside)
  • Page 7: Control Board

    ON/OFF HEALTH TEMP+ TEMP- 1. ON/OFF button 6. Operation mode display Used for unit start and stop. 7. POWER / SOFT display 2. MODE button 8. FAN SPEED display 3. AIR FLOW button 9. HEALTH display 10. Room temperature display, 4.
  • Page 8 Press it once again, lock will be Used to set healthy operation. canceled and lock condition display disappears. NOTE: Cooling only unit do not have functions and displays related with heating. The following functions and related displays are not available: 26 29...
  • Page 9 If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
  • Page 10: Operation

    The anion generator in the air conditioner can generate a FRESH lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the POWER/SOFT dust sediment in the room and finally clean the air in the room.
  • Page 11: Auto Operation

    POWER/SOFT rapidly Select a desired temperature. CODE 4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: AUTO Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
  • Page 12: Cool Operation

    C,if kept depressed, it will decrease rapidly HEALTH AIRFLOW Select a desired temperature. FRESH 4.Fan speed selection Press FAN button. For each press, fan speed changes as POWER/SOFT follows: Remote controller: CODE AUTO Air conditioner is running under displayed fan speed.
  • Page 13: Dry Operation

    1 C,if kept depressed, it will decrease rapidly Select a desired temperature. 4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: COOL operation starts when room Ultra-low air flow temp.is higher than temp.setting.
  • Page 14: Fan Operation

    Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL Then Select FAN operation 3.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: HEALTH AIRFLOW 4.Unit stop FRESH Press ON/OFF button, the unit stops.
  • Page 15: Air Flow Direction Adjustment

    NOTE: When we stop the air conditioner with remote controller or controlling plate, the flap will close automatically. If we cut off the power directly, the flap could not close itself. So you should shut off the machine with remote controller or controlling plate, You MUST NOT cut off the power when the machine is running.
  • Page 16: Sleep Operation

    1 hr another 1 hours, temp. rises by 1 C further. Unit stop The unit will run for further 6 hours then stops. Temp.setting In COOL, DRY mode Temp. is higher than temp. setting so that room temperature won't be too Iow for your sleep.
  • Page 17 After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one.
  • Page 18 " on the remote controller stops flashing. CODE " " starts flashing. Time displayed: Unit starts or stops at x hour x min. 5.Time setting for TIMER OFF Just press HOUR button ,follow the same procedure in "Time setting for TIMER ON"...
  • Page 19: Power Operation

    BLANK SOFT POWER Stop the display at In POWER operation status: Fan speed automatically runs in AUTO mode for 15 min , then returns to original status setting. To cancel POWER operation Press POWER/SOFT button twice ,POWER/SOFT disappears. SOFT Operation...
  • Page 20: Fan Speed Display

    "Hi". Unit stop (cancel the Test operation:) press the ON/OFF button once, then you will hear "Pi" sound and the unit will operate as what the remote controller shows. When you connect the power supply, all the signs of function will be displayed for 5 senconds.
  • Page 21: Operation Hints

    When sudden power failure happens during unit operation in power failure resume mode,if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press...
  • Page 22: Maintenance

    During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used Use the louvers effectively for a long time, turn off the power supply main switch. 晻 晻 晻 晻...
  • Page 23: Air Filter Cleaning

    Air Filter cleaning Press the clasp on the top of the grill and pull the grill out, and then the filter will be taken out along a gradient way. Clean the filter.
  • Page 24 To Keep Your Air conditioner in Good Condition after Season. 1. Operate in FAN mode for about half a day. On a fine day, unit shall be started and operate in FAN mode for about half a day until the inside of the unit becomes thoroughly dry.
  • Page 25 Before Setting in High season 1. Cleaning the standard air filter. Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes. 2. Connecting the earthing cable.
  • Page 26: Troubleshooting

    This noise is generated by the inspection casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells Smells are generated.