Haier HPU-18CRA13 Installation Manual

User manual
Hide thumbs Also See for HPU-18CRA13:

Advertisement

Quick Links

Installation Manual of Room Air Conditioner

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
Accessory parts
Number
No.
Accessory parts
of
articles
1
1
Remote controller
2
Accessory parts
2
R-03 dry battery
No.
Shape and description
1
3
Remote controller
Mounting plate
1
4
Drain hose
4
5
4X25
Plastic cap
Screw
1
6
Drain-elbow
4
7
Cushion
Piping hole cover
1
8
Pipe supporting plate
9
1
Connecting cable
Non-adhensive tape
L shape component
anti-fall componen
13
gasket
No.0010558082
No.0010513342
Necessary Tools for Installation
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
Drawing for the installation of indoor and outdoor units
Drawing for the installation of indoor and outdoor units
Optional parts for piping
QTY
Mark
Parts name
A
Non-adhesive tape
Adhesive tape
B
Cement nail
C
Saddle(L.S) with screws
Connecting electric cable
Drain hose
D
for indoor and outdoor
Drain hose
E
Screw
F
Heating insulating material
wire clip
G
Piping hole cover
Wall hole cover
Dry battery #7
Arrangement of piping directions
Cushion
Rear left
Left
Below
t
3
The marks from
A
to
in the figure are the parts numbers.
G
The distance between the indoor unit and the floor should be
more than 2m.
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
Read this manual before installation
Explain sufficiently the operating means to the user
9.Nipper
according to this manual.
10.Gas leakage detector or
11.Measuring tape
The models adopt HFC free refrigerant R410A
ON/OFF
Rear
right
Right
soap-and-water solution
AUTO
H
MODE
AIR FLOW
HEALTH
TEMP+
TEMP-
M
L
Attention must be paid to
the rising up of drain hose
12.Reamer

Advertisement

loading

Summary of Contents for Haier HPU-18CRA13

  • Page 1: Installation Manual Of Room Air Conditioner

    Rear left Rear Left right Non-adhensive tape Right Below L shape component anti-fall componen gasket The marks from in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m. No.0010558082 No.0010513342...
  • Page 2: Selection Of Installation Place

    Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate. Install an exclusive branch circuit of the power. A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it. Selection of pipe...
  • Page 3: Installation Of The Indoor Unit

    To bent a pipe, give the roundness as large as possible not to crash the pipe. When connecting pipe, hold the pipe center to center then screw nut on by hand, refer to Fig. Be careful not to let foreign matters, such as sands enter the pipe.
  • Page 4 ( 1 ) Arrangement of connecting pipe and drainage pipe After opening inlet grill, you will see a control box as shown in the below left picture. Remove the cover before working. According to the piping method, connect the piping on indoor unit with union of connection pipe. Arrange the piping as per the wall hole and bild drain hose connecting electric cable and piping together with polyethylene tape.
  • Page 5 Insert the cable from outside the wall hole where piping already exist. Put it out from front. Losen terminal screw and insert cable end fully into terminal block, then tighten it . Pull the cable gently to make sure it is tight.
  • Page 6 Air conditioner must use an exclusive line(over 20A). There is not power plug with the type of 18k, and there is not power cable with the type of 24k. When installation air conditioner in a wet place , try to use a circuit breaker against current leakage.