Advertisement

Quick Links

MOBILE TYPE AIR CONDITIONERS(Local Air Conditioners)
Owner's Manual &
Installation Manual
Model: MPPFA1-09CRN7
MPPFB1-12CRN7
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Make sure to save this manual for
future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MPPFA1-09CRN7 and is the answer not in the manual?

Questions and answers

Victor
July 8, 2025

how many amps for the socket

User image 686d5b9e385b0

Summary of Contents for Midea MPPFA1-09CRN7

  • Page 1 MOBILE TYPE AIR CONDITIONERS(Local Air Conditioners) Owner’s Manual & Installation Manual Model: MPPFA1-09CRN7 MPPFB1-12CRN7 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
  • Page 2: Table Of Contents

    Table of Contents 应品质要 求,增加 出风口与 障碍物距 离50cm(工 程师提供 Safety Precautions 的数据)。 Safety Precautions ........................Installation Instructions Preparation..........................Design Notice..........................Ambient Temperature Range For Unit Operating................. Exhaust Hose Installation......................Choosing The Right Location...................... Energy Rating Information ......................12 Tools Needed..........................Accessories..........................
  • Page 3: Safety Precautions

    Safety Precautions 原D Read Safety Precautions Before Operation and Installation To prevent death or injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause death, harm or damage. CAUTION WARNING This symbol indicates the possibility of...
  • Page 4 In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning. • Your air conditioner should be used in such a way that it is protected from moisture. • e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can 机型中单页的DOE说明,现整合到整机说明书中。...
  • Page 5 • Disconnect the power if strange sounds, smell, or smoke comes from it. Do not press the buttons on the control panel with anything other than your fingers. • Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has •...
  • Page 6 WARNING for Using R32/R290 Refrigerant Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater). Do not pierce or burn.
  • Page 7 1.Transport of equipment containing flammable refrigerants See transport regulations 2.Marking of equipment using signs See local regulations 3.Disposal of equipment using flammable refrigerants See national regulations. 4.Storage of equipment/appliances The storage of equipment should be in accordance with the manufacturer's instructions. 5.Storage of packed (unsold) equipment Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge.
  • Page 8 8)Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer's maintenance and service guidelines shall be followed. If in doubt consult the manufacturer's technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: The charge size is in accordance with the room size within which the refrigerant containing parts are installed;...
  • Page 9 9.Cabling Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans. 10.Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks.
  • Page 10 14.Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant.
  • Page 11: Installation Instructions

    Installation Instructions Preparation CThe unit can be controlled by the unit control panel alone or with the remote controller. This manual does not include Remote Controller Operations, see the <<Remote Controller Instruction>> packed with the unit for details. control panel upper air filter handle (both sides)
  • Page 12: Choosing The Right Location

    Choosing The Right Location Your installation location should meet the following requirements: -Make sure that you install your unit on an even surface to minimize noise and vibration. -The unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible.
  • Page 13: Tools Needed

    number means more cooling power for a larger room. (Be sure you are comparing only newer models to each other- older models may appear to have a higher capacity, but are actually the same). Be sure to “size up” if your portable air conditioner will be placed in a very sunny room, in a kitchen, or in a room with high ceilings.
  • Page 14: Window Installation Kit

    Other Regions Shape Qty. Shape Qty. Name of Accessories Name of Accessories Unit Adaptor 1 pc Security Bracket and 2 Screws 1 set(*) Exhaust Hose 1 pc Drain Hose 1 pc Window Slider Adaptor 1 pc(*) Power Cord Buckle 1 pc Window Slider A 1 pc(*) Bolt...
  • Page 15: Installation

    Bolt Bolt Step Three: Preparing the Adjustable Window Slider Window slider A Window slider B Window slider A Window slider B 1. Depending on the size of your window, adjust MODEL A MODEL B the size of the window slider. Bolts 2.
  • Page 16 Security Bracket Security Bracket 2 Screws 2 Screws 4. If desired, install the security bracket with 2 screws as shown. 之前的说明书房屋最小面积与型号相对应, 容易因忘换客户型号导致说明书出错。现与 冷媒量相对应,同时引导用户看铭牌上参数。 认证反馈R32机型暂不用在说明书中标最小房屋面积。 5. Insert the window slider adaptor into the hole of the window slider. Type 2: Wall Installation(For some models) 1.
  • Page 17: Operating Instructions

    Operating Instructions Control Panel Features NOTE: The following control panels are for explanation purpose only. The control panel of the unit you purchased may be slightly different according to the models. Your machine may not contain some indicators or buttons. The actual shape shall prevail. Wireless Wireless button(On some models) NOTE: After 250 hours of operation, the filter...
  • Page 18: Operation Instructions

    Up (+) and Down (-) buttons E1-Room temperature sensor error. Used to adjust (increasing/decreasing) E2-Evaporator temperature sensor error. temperature settings in 1°C/1°F (or 2°F) E3-Condenser temperature sensor error (on some increments in a range of 17°C/62°F to 30°C/86°F models). (or 88°F) or the TIMER setting in a range of 0~ E4-Display panel communication error.
  • Page 19: Other Features

    light illuminates. Press the up or down button to SLEEP/ECO operation select the desired Auto-on start time. · Press this button, the selected temperature will · When the unit is off, press the Timer button to initiate increase(cooling) or decrease(heating) by 1°C/2°F(or the Auto-on start program, press it again within five 1°F) 30 minutes.The temperature will then increase seconds will initiate the Auto-off stop program.
  • Page 20: Safety Precautions

    with ).When the continuous drain hose is not used, ensure that the corresponding drain plug and knob are installed firmly to prevent leakage. Remove the upper drain plug drain hose Continuous adaptor √ drain hose drain hose √ adaptor · During heating pump mode, remove the lower drain Press the power cord buckle into plug from the back of the unit, install the drain...
  • Page 21: Air Filter Cleaning

    Air Filter Cleaning CAUTION DO NOT operate the unit without filter because dirt and lint will clog it and reduce performance. Upper filter (take out) lower filter A (Press the grill down slightly and pull the lower Maintenance Tips filter A out at the same time) ·...
  • Page 22: Troubleshooting Tips

    Troubleshooting Tips Problem Possible Causes Solution The Water Collection Tray is full. Turn off the P1 Error Code unit, drain the water from the Water Collection Tray and restart the unit. Unit does not turn on when pressing In COOL mode: room ON/OFF button temperature is lower than Reset the temperature...
  • Page 23 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version. CP004UI-PF...
  • Page 24 REMOTE CONTROLLER OWNER’S MANUAL Model: MPPFA1-09CRN7 MPPFB1-12CRN7 IMPORTANT NOTE: Thank you for purchasing our air conditioner. Please read this manual carefully before operating your new air conditioning unit. Make sure to save this manual for future reference.
  • Page 26 Table of Contents Remote Controller Specifications ..........02 Handling the Remote Controller ..........03 Buttons and Functions ..............04 Remote Screen Indicators .............06 How to Use Basic Functions ............07 How to Use Advanced Functions ..........10...
  • Page 27: Remote Controller Specifications

    Remote Controller Specifications RG10F(B)/BGEF、RG10F1(B)/BGEF、 Model RG10F2(B1)/BGEFU1、RG10F3(B1)/BGEFU1 3.0V( Dry batteries R03/LR03×2) Rated Voltage Signal Receiving Range -5°C~60°C(23°F~140°F) Environment Quick Start Guide AUTO COOL HEAT FIT BATTERIES SELECT MODE SELECT TEMPERATURE SELECT FAN SPEED POINT REMOTE TOWARD UNIT PRESS POWER BUTTON NOT SURE WHAT A FUNCTION DOES? Refer to the How to Use Basic Functions and sections of this How to Use Advanced Functions...
  • Page 28: Handling The Remote Controller

    Handling the Remote Controller Inserting and Replacing Batteries NOTES FOR USING REMOTE CONTROL Your air conditioning unit may come with two The device could comply with the local batteries(some units). Put the batteries in the national regulations. remote control before use. In Canada, it should comply with •...
  • Page 29: Buttons And Functions

    Buttons and Funcitons Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the section of this manual.
  • Page 30 ON/OFF MODE Turns the unit on or o . Scrolls through operation modes as follows: AUTO  COOL  TEMP DRY  HEAT  FAN Increases temperate in 1°C (1°F) increments. NOTE: Please do not select Max. temperature is HEAT mode if the machine you 30°C (86°F ).
  • Page 31: Remote Screen Indicators

    Remote Screen Indicators Information are displayed when the remote controller is power up. Fresh feature display(some units) (No displays when Fresh feature is activated) Sleep mode display Follow me feature display Wireless control feature display Indicator Transmission Low battery detection display(If ashes) Lights up when remote sends signal to indoor MODE...
  • Page 32: How To Use Basic Functions

    How to Use Basic Functions Basic operation COOL Mode ATTENTION! Before operation, please ensure the unit is plugged in and power is available. SETTING TEMPERATURE The operating temperature range for units is 17°C-30°C (62°F-86°F). You can increase or decrease the set temperature in 1°C (1°F) increments.
  • Page 33 Press the button to select mode. MODE DRY Mode (dehumidifying) Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH. Press the button to start the unit. ON/OFF NOTE: You can’t set temperature in mode. As a result, your remote control’s screen will not display temperature.
  • Page 34 Setting the TIMER TIMER ON/OFF - Set the amount of time after which the unit will automatically turn on/off. TIMER ON setting Press TIMER ON button to Press up or down button for Point remote to unit and wait initiate the ON time sequence. multiple times to set the desired 1sec, the TIMER ON will be time to turn on the unit.
  • Page 35: How To Use Advanced Functions

    How to Use Advanced Functions SHORTCUT function Swing function Press Swing button Press SHORTCUT button The horizontal louver will swing up and Push this button when remote controller is on, downautomatically when pressing Swing the system will automatically revert back to button.
  • Page 36 SLEEP Function LOCK function Press SLEEP button Press together button and I SENSE or The SLEEP function is used to decrease button at the same time more than 5 °C/°F energy while you sleep(and don’t need seconds to activate Lock function. the same temperature settings to stay All buttons will not response except pressing comfortable).
  • Page 37 SET function • Press the SET button to enter the function setting, then press SET button or TEMP or TEMP button to select the desired function. The selected symbol will ash on the display area, press the OK button to con rm. •...
  • Page 38 WARRANTY CARD MIDEA MOBILE TYPE AIR CONDITIONERS Thank you for purchasing this midea portable air condi�oning unit. Should your product prove to be defec�ve in material or workmanship under normal use within the 1 Year of ownership we will replace the defec�ve part(s) we deem to be faulty, or at our discre�on replace the en�re product.