Advertisement

Quick Links

PORTABLE AIR CONDITIONER(Local Air Conditioner)
Owner's Manual &
Installation Manual
MPPQ-09CRN7-QB6
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Make sure to save this manual for
future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MPPQ-09CRN7-QB6 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Midea MPPQ-09CRN7-QB6

  • Page 1 PORTABLE AIR CONDITIONER(Local Air Conditioner) Owner’s Manual & Installation Manual MPPQ-09CRN7-QB6 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
  • Page 2: Table Of Contents

    Table of Contents Safety Precautions Safety Precautions ................................Installation Instructions Preparation.................................... Design Notice..................................Ambient Temperature Range For Unit Operating....................Exhaust Hose Installation..............................Choosing The Right Location............................Energy Rating Information ............................. 12 Tools Needed..................................Accessories..................................... Window Installation Kit..............................Installation....................................Operating Instructions Control Panel Features..............................
  • Page 3: Safety Precautions

    Safety Precautions Read Safety Precautions Before Operation and Installation To prevent death or injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause death, harm or damage. CAUTION WARNING This symbol indicates the possibility of...
  • Page 4 In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning. • Your air conditioner should be used in such a way that it is protected from moisture. • e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid.
  • Page 5 Disconnect the power if strange sounds, smell, or smoke comes from it. • Do not press the buttons on the control panel with anything other than your fingers. • Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has •...
  • Page 6 WARNING for Using R32/R290 Refrigerant Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater). Do not pierce or burn.
  • Page 7 1.Transport of equipment containing flammable refrigerants See transport regulations 2.Marking of equipment using signs See local regulations 3.Disposal of equipment using flammable refrigerants See national regulations. 4.Storage of equipment/appliances The storage of equipment should be in accordance with the manufacturer's instructions. 5.Storage of packed (unsold) equipment Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge.
  • Page 8 8)Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer's maintenance and service guidelines shall be followed. If in doubt consult the manufacturer's technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: The charge size is in accordance with the room size within which the refrigerant containing parts are installed;...
  • Page 9 9.Cabling Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans. 10.Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks.
  • Page 10 14.Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant.
  • Page 11: Installation Instructions

    Installation Instructions Preparation NOTE: All the illustrations in the manual are for explanation purpose only. Your machine may be slightly different. The actual shape shall prevail. The unit can be controlled by the unit control panel alone or with the remote controller.
  • Page 12: Choosing The Right Location

    Choosing The Right Location Your installation location should meet the following requirements: 应品质 要求, -Make sure that you install your unit on an even surface to minimize noise and 增加上 vibration. 出风口 -The unit must be installed near a grounded plug, and the Collection Tray Drain 与障碍...
  • Page 13: Tools Needed

    number means more cooling power for a larger room. (Be sure you are comparing only newer models to each other- older models may appear to have a higher capacity, but are actually the same). Be sure to “size up” if your portable air conditioner will be placed in a very sunny room, in a kitchen, or in a room with high ceilings.
  • Page 14: Window Installation Kit

    Other Regions Qty. Qty. Shape Shape Name of Accessories Name of Accessories Unit Adaptor 1 pc Security Bracket and 2 Screws 1 set(*) Exhaust Hose 1 pc Drain Hose 1 pc Window Slider Adaptor 1 pc(*) Power Cord Buckle 1 pc Window Slider A 1 pc(*) Bolt...
  • Page 15: Installation

    Bolt Step Three: Preparing the Adjustable Window Slider Window slider A Window slider B 1. Depending on the size of your window, adjust the size of the window slider. 2. If the length of the window requires two or three Bolts window sliders, use the bolt(s) to fasten the window sliders once they are adjusted to the...
  • Page 16 Security Bracket Security Bracket 2 Screws 2 Screws 4. If desired, install the security bracket with 2 screws as shown. 5. Insert the window slider adaptor into the hole of the window slider. Type 2: Wall Installation(For some models) 1. Cut a 125mm (4.9inch) hole into the wall for the Wall Exhaust Adaptor B. 2.
  • Page 17: Operating Instructions

    Operating Instructions Control Panel Features NOTE: The following control panels are for explanation purpose only. The control panel of the unit you purchased may be slightly different according to the models. Your machine may not contain some indicators or buttons. The actual shape shall prevail. 基准说明书同时展示PQ与PB全功能显示标贴,如客户...
  • Page 18 Sleep(Eco)/Filter button Swing/Wireless(On some models) button Used to initiate the Auto swing feature. Used to initiate the SLEEP/ECO operation. Press the SWING button can stop the louver NOTE: After 250 hours of operation, the filter at the desired angle. indicator light illuminates. This feature is a reminder to clean the Air Filter for more Used to initiate the Wireless connection mode.
  • Page 19: Operation Instructions

    NOTE: When one of the above malfunctions occurs, turn off the unit and unplug the power cord. turn off the unit, and check for any obstructions. Contact the manufacturer or its service agents or a Restart the unit, if the malfunction is still present, similar qualified person for service.
  • Page 20: Other Features

    Other features FOLLOW ME/TEMP SENSING feature(On some models) Water drainage NOTE:This feature can be activated from the remote · During dehumidifying modes, remove the upper control ONLY. The remote control serves as a remote drain plug from the back of the unit, install the drain thermostat allowing for the precise temperature connector(5/8"...
  • Page 21: Maintenance

    NOTE: Make sure the hose is secure so there are no NOTE: Be sure to reinstall the bottom drain plug firmly leaks. Direct the hose toward the drain, making sure to prevent leakage before using the unit. that there are no kinks that will stop the warter flowing. When the water drainage function is not in use, Place the end of the hose into the drain and make sure keep the upper and the lower drain plug firmly to...
  • Page 22: Store The Unit When Not In Use

    Store the unit when not in use · Drain the unit’s water collection tray according to the instructions in the following section. · Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mold. ·...
  • Page 23 Impedance Information The model MPPB-14CRN7-QB6 should be connected only to a supply with the relevant system impedance no more than 0.316 ohm. Restrictions to connection may be imposed by the supply authority on the use of equipment in the actual relevant system impedance at the interface point on the user’s premise exceeds 0.
  • Page 24 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version. CP002UI-PB(PQ)
  • Page 25 REMOTE CONTROLLER OWNER’S MANUAL IMPORTANT NOTE: Thank you for purchasing our air conditioner. Please read this manual carefully before operating your new air conditioning unit. Make sure to save this manual for future reference.
  • Page 27 Table of Contents Remote Controller Specifications ..........02 Handling the Remote Controller ..........03 Buttons and Functions ..............04 Remote Screen Indicators .............06 How to Use Basic Functions ............07 How to Use Advanced Functions ..........10...
  • Page 28: Remote Controller Specifications

    Remote Controller Specifications RG10F(B)/BGEF、RG10F1(B)/BGEF、 Model RG10F2(B1)/BGEFU1、RG10F3(B1)/BGEFU1 3.0V( Dry batteries R03/LR03×2) Rated Voltage Signal Receiving Range -5°C~60°C(23°F~140°F) Environment Quick Start Guide AUTO COOL HEAT FIT BATTERIES SELECT MODE SELECT TEMPERATURE SELECT FAN SPEED PRESS POWER BUTTON POINT REMOTE TOWARD UNIT NOT SURE WHAT A FUNCTION DOES? Refer to the How to Use Basic Functions and sections of this How to Use Advanced Functions...
  • Page 29: Handling The Remote Controller

    Handling the Remote Controller NOTES FOR USING REMOTE CONTROL Inserting and Replacing Batteries Your air conditioning unit may come with two The device could comply with the local batteries(some units). Put the batteries in the national regulations. remote control before use. In Canada, it should comply with •...
  • Page 30: Buttons And Functions

    Buttons and Funcitons Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the section of this manual.
  • Page 31 ON/OFF MODE Turns the unit on or off. Scrolls through operation modes as follows: AUTO  COOL  TEMP Increases temperate in DRY  HEAT  FAN 1°C (1°F) increments. NOTE: Please do not select Max. temperature is HEAT mode if the machine you 30°C (86°F ).
  • Page 32: Remote Screen Indicators

    Remote Screen Indicators Information are displayed when the remote controller is power up. Fresh feature display(some units) (No displays when Fresh feature is activated) Sleep mode display Follow me feature display Wireless control feature display Indicator Transmission Low battery detection display(If flashes) Lights up when remote sends signal to indoor display...
  • Page 33: How To Use Basic Functions

    How to Use Basic Functions Basic operation COOL Mode ATTENTION! Before operation, please ensure the unit is plugged in and power is available. SETTING TEMPERATURE The operating temperature range for units is 17°C-30°C (62°F-86°F). You can increase or decrease the set temperature in 1°C (1°F) increments.
  • Page 34 DRY Mode (dehumidifying) Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH. Press the button to start the unit. ON/OFF You can’t set temperature in mode. NOTE: As a result, your remote control’s screen will not display temperature. HEAT Mode 1.
  • Page 35 Setting the TIMER TIMER ON/OFF - Set the amount of time after which the unit will automatically turn on/off. TIMER ON setting Press TIMER ON button to Press up or down button for Point remote to unit and wait initiate the ON time sequence. multiple times to set the desired 1sec, the TIMER ON will be time to turn on the unit.
  • Page 36: How To Use Advanced Functions

    How to Use Advanced Functions SHORTCUT function Swing function Press Swing button Press SHORTCUT button The horizontal louver will swing up and Push this button when remote controller is on, downautomatically when pressing Swing the system will automatically revert back to button.
  • Page 37 SLEEP Function LOCK function Press SLEEP button The SLEEP function is used to decrease energy while you sleep(and don’t need the same temperature settings to stay comfortable). This function can only by activated via remote control. For the details, please see “sleep operation ” in “...
  • Page 38 SET function Press the SET button to enter the function setting, then press SET button or TEMP or TEMP • button to select the desired function. The selected symbol will flash on the display area, press the OK button to confirm. To cancel the selected function, just perform the same procedures as above.
  • Page 40 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. CR271-RG10F(B)

Table of Contents