Technical specifications
13 Technical specifications
Device short description:
Supply voltage:
Current consumption:
Power consumption in standby:
Max. switching capacity:
Output 1:
Output 2:
Cable type and cross section:
Kind of load:
Method of operation:
switching cycle:
Relay:
Withstand voltage:
Temperature glow wire test:
Temperature ball pressure test:
Construction:
Pollution degree:
Protection rating:
Protection class:
Ambient temperature:
Dimensions (W x H x D):
Weight:
Radio frequency band:
Max. radio transmission power:
Receiver category:
Typical range in open space:
Duty cycle:
Subject to modifications.
HmIP-MIOB
230 V/50 Hz
30 mA max.
250 mW
3680 W, cosφ≥0,95 (floating)
1840 W, cosφ≥0,95 (floating)
rigid and flexible cable, 0.75 - 2.5 mm²
ohmic load
Type 1.B
10000
Changeover contact, 1-pole, µ contact
NO contact, 1-pole, µ contact
4000 V
850°C
125°C
Independently mounted
electronic regulation and control de-
vice
2
IP20
I
0 - 50°C
199 x 156 x 34 mm
365 g
868.0 – 868.6 MHz
869.4 – 869.65 MHz
10 dBm
SRD category 2
380 m
< 1 % per h/< 10 % per h
32