  • Page 1 ECHO PRO AC Wall Mounted EV charger ELECTRIC VEHICLE CHARGER INSTALLATION AND INSTRUCTION MANUAL...
  • Page 2: Table Of Contents

    CONTENTS SAFETY ....................................3 Safety Identification ...............................3 INTRODUCTION..................................7 Appearance ..................................7 Technical Specifications ..............................8 Manual Information ................................9 Terminology ..................................10 Product model ................................10 Lighting Language .................................10 INSTALLATION ..................................11 Procedure ..................................11 Accessory List ................................11 Site preparation ................................12 Unpacking The Charger ...............................12 Mounting The Plate ..............................13 Mounting The Charger ..............................14 Wiring ....................................15 Daisy Chain ..................................16...
  • Page 3: Safety

    The Owner must take the necessary steps to protect the AC charger, network, system, and interface from any security breaches, unauthorized access, interfering, intrusion, leakage, or theft of data or information. Hydra EVC shall not be liable for any damages or losses incurred as a result of security breaches.
  • Page 4: Introduction

    INTRODUCTION APPEARANCE Car Parks / Public Charging Station Material Metal housing Installation type Wall Mounted Cable layout Bottom Weight 18kg Charging socket Type 2 Touch Screen RFID Card reader LED status lights Power input Charger Socket ➊ ➊ ➋ ➋ ➎...
  • Page 5: Technical Specifications

    INTRODUCTION TECHNICAL SPECIFICATIONS Dimensions (mm) L500 x W240 x D199 (mm) Weight 18kg Operating Temperature -25°C to +50°C General Storage Temperature -40°C to +80°C Material ABS Plastic and aluminium alloy Certifications CE/UKCA Charing Power 7.4/22kW Charging Current 6-32A (adjustable) per phase Voltage 230/400V (1/3-phase, 50-60Hz) Charging Mode...
  • Page 6: Manual Information

    Hydra EVC is not responsible for any losses or damages that may arise from using this document, including but not limited to lost profit or data. If you use or modify the Hydra EVC AC charging station in a way that is not intended to be used or modify the charge point, your limited warranty will be void.
  • Page 7: Terminology

    Residual Current Breaker with Over Current Device RFID Radio-frequency Identification PRODUCT MODEL Part Code Version HE-P-22-SO Hydra Echo Pro 22kw Socket Only LIGHTNING LANGUAGE LED Ring Status Description Power LED Charger Free Ring Light Green On Reservation Ring Light Blue On...
  • Page 8: Installation

    INSTALLATION PROCEDURE SAFETY INSTRUCTIONS The operating voltage and current inside the charging system are high, and the following regulations should be observed at all times to ensure personal safety: 1. Charging systems must only be installed by personnel who have been trained in, and have sufficient knowledge of, the charging system.
  • Page 9: Site Preparation

    SITE PREPARATION Before installation, all local legal requirements applicable to the installation site must be met. Before installation of the Hydra Genesis AC public charger, ensure that: • Concentrate foundation base is prepared according to the manual. • Space and the airflow around the cabinet is suffcient.
  • Page 10: Mounting The Plate

    INSTALLATION MOUNTING THE PLATE 1. Make sure that the installation is level on the wall, and recommended height is about 800-1200 mm. 2. Drill the mounting holes. 3. Charger back module install-fix on the panel. Screw M5*60 x 4 Screw M8*60 x 4 4 PCS 4 PCS ✆...
  • Page 11: Mounting The Charger

    INSTALLATION MOUNTING THE CHARGER 1. Confirm the power input location, and back module support top and bottom input. 2. Fix the charging module with back module after finish the power connection. • We recommend to the height for wallbox is about 800-1200mm •...
  • Page 12: Wiring

    INSTALLATION WIRING Connect the AC input wires 1. Trim the wires L1, L2, L3, PE and N. And make sure that the length is suffcient for connection at the connectors 2. Strip the insulation from the end of the wires. Make sure that the strip length is compatible with the cable lugs 3.
  • Page 13: Daisy Chain

    INSTALLATION DAISY CHAIN There are two ways for input cable of wallbox charger (Top or Bottom), make sure that use the bottom way if the wallbox installed outdoor. (This is limited to two units only) ✆ 01268 205 121 | www.hydrainstall.co.uk | enquiry@hydrainstall.co.uk...
  • Page 14: Connecting Ethernet

    INSTALLATION CONNECTING ETHERNET The charger can be connected to the Internet by Ethernet connection, Wi-Fi or a SIM card. 1.To connect via the Ethernet cable, put the RJ45 plug of the Ethernet cable into the RJ45 port (H) in the back module of charger.
  • Page 15: Sim Card

    SIM CARD SIM CARD INSTALLATION When planning the SIM card connection for charger at a site, there are a few key considerations to keep in mind. It is important to choose a reliable and robust network provider that offers good coverage in the area where the charger will be installed.
  • Page 16: Commissioning

    Commissioning is the necessary before the charger operation. The purpose is to check the safety and performance of the charging system for operational purposes. A qualified service engineer from Hydra EVC service or a qualified engineer is required to go to the site for commissioning. During commission-ing, the system safety performance and the function of charging will be tested.
  • Page 17: Setting Up The Charger

    COMMISSIONING SETTING UP THE CHARGER Be careful when you work with electricity The power supply comes on and test all the input voltage with multi-meter tool. A series of self-checks start, to make sure that the charger works correctly and safely. 1.
  • Page 18: Protection

    PROTECTION PROTECTIVE DEVICE Devices Specifications Options: Dedicated upstream protection device(s) RCD (Type A minimum) + MCB RCBO (Type A minimum) Upstream overcurrent protection breaker, such Breaker rating: as RCBO or MCB (The breaker serves as the main 40 A for a wallbox &Pedestal single charger 80 A for disconnect switch to the charger.) Pedestal Dual charger Minimum Type A, with a rated residual operation...
  • Page 19: Charging Operation

    CHARGING OPERATION CHARGING PROCEDURE System Start Up Power on the charger, the charger will start initializing and display power on page. After initializing, when charger is standby, will stay on ‘Home’ page a. Plug in car b. Select operations from options on the screen Authorize to start a charging session...
  • Page 20 CHARGING OPERATION CHARGING PROCEDURE Charging page a. Select ‘stop’ button, will go to authorization page to stop. b. Select ‘Price’ will display unit price per kWh or per minute. c. Select ‘Home’ button will return to the home page. d. Select ‘details’ button will display more charging info.
  • Page 21: Service

    SERVICE In product life cycle, if you cannot find solutions to your problems about software, hardware or others with the aid from the table above, please contact Hydra EVC Technical Support. Hydra EVC Ltd Email: support@hydraev.co.uk Address: Unit 11 Totman Close, Rayleigh, Essex, SS6 7UZ...
  • Page 22: Aftersales

    AFTER-SALES MAINTENANCE AFTER-SALES SERVICE • Parts are covered by a three-year warranty. • During this period any defective part will be replaced. • One-to-one technical engineer support is available. DISCLAIMER Product equipment must be used under certain conditions. Should the following circumstances lead to an accident or damage, we will not be held responsible.
  • Page 23 AFTER-SALES MAINTENANCE MAINTENANCE (CONTINUED) SEMI-ANNUALLY Check ground bolt torque and tighten if required. ANNUALLY Check all internal components. ON-SITE MAINTENANCE This device is an internet of Things-type charger with pre-charge self-test, daily regular self-test, online monitoring of electrical parts and other intelligent functions. •...