brewer FLEX High-Low Installation And Operation Manual

brewer FLEX High-Low Installation And Operation Manual

Exam tables

Advertisement

FLEX High-Low and FLEX High-Low PLUS
Installation and Operation Manual
FLEX High-Low
Exam Table
Safety Information ........................................................ 2
Important Information ................................................... 3
Component Identification .............................................. 5
Specifications ............................................................... 6
Installation .................................................................... 8
Operation .................................................................... 15
Simply go to brewercompany.com/warranty-registration, fill out the information fields and click submit.
By registering your product today, you are better safeguarding your investment in the future.
Printed in USA © 2024
FLEX High-Low
Exam Tables
Registering your Brewer product is easy.
The Brewer Company, LLC
N88 W13901 Main Street, Suite 100
Menomonee Falls, WI 53051
P 1.888.Brewer.1
F 262.251.2332
E customerservice@brewercompany.com
www.brewercompany.com
Exam Table
FLEX High-Low
PLUS Exam Table
Maintenance ............................................................... 27
Service........................................................................ 28
Accessories ................................................................ 29
Power Cord Options .................................................. 29
Warranty ..................................................................... 30
Document 2102861 RevI

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLEX High-Low and is the answer not in the manual?

Questions and answers

Rose Baez, MD
July 10, 2025

Does this table have an alarm? Ours is beeping loudly

Subscribe to Our Youtube Channel

Summary of Contents for brewer FLEX High-Low

  • Page 1: Table Of Contents

    FLEX High-Low Exam Table FLEX High-Low and FLEX High-Low PLUS Exam Tables Installation and Operation Manual FLEX High-Low PLUS Exam Table FLEX High-Low Exam Table Safety Information ............2 Maintenance ............... 27 Important Information ........... 3 Service................ 28 Component Identification ..........5 Accessories ..............
  • Page 2: Safety Information

    Exam Table SAFETY INFORMATION Safety Information Symbols The primary concern of The Brewer Company is that the Yellow triangle with black border and equipment is operated and maintained with the safety of black symbol warns of a hazardous the patient and healthcare staff in mind. To ensure safe situation.
  • Page 3: Important Information

    In addition to the controlled positions noted above, several manual adjustments are available: The Brewer Flex and Flex PLUS High-Low Exam Table Models 5700, 5800, 5700PLUS and 5800PLUS Series are •...
  • Page 4 IMPORTANT INFORMATION (CONTINUED) Service If you require assistance with the installation or operation of your Brewer Table, call the Brewer Customer Experience Department at (1-800-558-8777). Our trained staff will attempt to assist you in correcting the problem directly over the phone. If service is required, a factory authorized technician may be sent to your location.
  • Page 5: Component Identification

    FLEX High-Low Exam Table COMPONENT IDENTIFICATION Patient Assist Handles (Models 5701, 5801, 5701PLUS, 5801PLUS) Pelvic Tilt (Models 5701, 5801, 5701PLUS, 5801PLUS only) Pass-Through Work Surface SafeGlide™ Slide-out Leg Support EasyGlide Mobility Treatment Pan (option available on all PLUS models) (located under Leg...
  • Page 6: Specifications

    FLEX High-Low Exam Table SPECIFICATIONS Weight of Table Fuse Rating • Models 5700, 5701, 5800, 5801 ......315 lbs. • Option/Warmer & Outlet Fuse Rating ..250V/1.0 Amp • Models 5700PLUS, 5701PLUS, 5800PLUS, • Outlet Max Load ..........2.0 Amp 5801PLUS ............330 lbs.
  • Page 7 FLEX High-Low Exam Table SPECIFICATIONS (CONTINUED) WARNING: Explosion/Fire Hazard Do not use this table in an explosive or oxygen rich atmosphere. Doing so may result in serious personal injury or death. WARNING: Shock Hazard When performing cauterization or similar treatment, the patient must be insulated from the metal portions of the table by non-conductive material.
  • Page 8: Installation

    FLEX High-Low Exam Table INSTALLATION NOTICE: Inspect Carton and Contents Inspect all boxes and contents for damage. Report any damage to the carrier immediately. NOTICE: No Sharp Tools To avoid damaging the table’s upholstery or painted surfaces, DO NOT use a knife or other sharp object to open the packaging.
  • Page 9 FLEX High-Low Exam Table INSTALLATION (CONTINUED) 3. Remove stretch wrap surrounding table. 6. Remove the 2 screws attaching the spacers on either side of the wooden U-shaped brace located under the 4. Remove the 2-4 steel shipping brackets securing front corners of the cabinet (Figure 6). Remove the the table to the pallet (Figure 4).
  • Page 10 FLEX High-Low Exam Table INSTALLATION (CONTINUED) 8. Make sure all shipping materials (except for wooden WARNING: Area Not Clear Hazard brace and spacers) and packing foam are removed Before initiating movement keep personnel and from the table, pallet and surrounding area.
  • Page 11 FLEX High-Low Exam Table INSTALLATION (CONTINUED) 12. Press “Lift Up” on the foot control to raise the seat 14. Unplug foot control and power cord and place into front approximately 1" (Figure 10). Remove the wooden storage drawer (Figure 12).
  • Page 12 FLEX High-Low Exam Table INSTALLATION (CONTINUED) 15. Use leg support to slide table partially off of pallet. NOTICE: Avoid Stirrup Damage Stop when there is sufficient room to place a furniture Do not lift or move table by using the stirrups as a hand hold.
  • Page 13 FLEX High-Low Exam Table INSTALLATION (CONTINUED) Leveling the Table Adjusting the Rear Base Extension After leveling the table, the Rear Base Extension should Tools Required be brought into contact with the floor (Figure 19). If • None EasyGlide option is installed, ensure it is not deployed.
  • Page 14 FLEX High-Low Exam Table INSTALLATION (CONTINUED) Installing the Power Cord 1. Remove the power cord from the front drawer. Foot Control 2. Insert the female plug end of the power cord into the Receptacle receptacle on the table. Make sure the plug is fully seated (Figure 20).
  • Page 15: Operation

    OPERATION Before Use CAUTION: Read this Manual WARNING: Shock Hazard Read this manual before use of the Brewer FLEX When performing cauterization or similar High-Low or High-Low PLUS Examination Table. treatment, the patient must be insulated from the metal portions of the table by non-conductive material.
  • Page 16 FLEX High-Low Exam Table OPERATION (CONTINUED) Models 5700, 5701, 5700PLUS & 5701PLUS Seat and Backrest Safety Switches Models 5700, 5701, 5700PLUS and 5701PLUS are Seat Switch equipped with a single pedal foot control that raises and All models are equipped with switches on the seat bottom lowers the seat.
  • Page 17 FLEX High-Low Exam Table OPERATION (CONTINUED) Backrest Switch Leg Support Pad All models are equipped with a switch on the top shroud The leg support pad can be slid beneath the seat with the (Figure 24) which automatically stops the lowering...
  • Page 18 FLEX High-Low Exam Table OPERATION (CONTINUED) Front Drawer Paper Roll Holder A storage drawer for supplies is located at the front of the To change a paper roll, remove old paper roll tube, place table. Models 5701, 5801, 5701PLUS and 5801PLUS...
  • Page 19 FLEX High-Low Exam Table OPERATION (CONTINUED) Pass-Through Work Surface (Optional) Removing the Work Surface for Cleaning 1. Push work surface in to reveal a white plastic screw. A pass-through work surface, stored under the seat (Figure 30), may be pulled out from either side of the 2.
  • Page 20 FLEX High-Low Exam Table OPERATION (CONTINUED) Adjustable Stirrups (Standard on Models 5701, 5801, 5701PLUS and 5801PLUS) (Optional on Models 5700, 5800, 5700PLUS and 5800PLUS) Operating the Stirrups Slide Stirrup Out 1. To operate the stirrups, grasp end of stirrup and pull straight out of the table (Figure 33).
  • Page 21 FLEX High-Low Exam Table OPERATION (CONTINUED) Patient Assist Handles (Optional) Table Height In the forward (normal use) position, the Patient Assist The table can be adjusted to any height between 18" to Handles lock into place preventing left or right rotation.
  • Page 22 FLEX High-Low Exam Table OPERATION (CONTINUED) Seat Back Return to Chair Button The back can be adjusted to any angle between Models 5800, 5801, 5800PLUS & 5801PLUS horizontal and 80°. NOTICE: To Lower Backrest Fully STOP RETURN TO CHAIR Table must be raised to a height of 28" before the backrest can be lowered to the horizontal position (Figure 37).
  • Page 23 FLEX High-Low Exam Table OPERATION (CONTINUED) Manual Pelvic Tilt Minimum Height (Models 5701, 5801, 5701PLUS and For lowering 5801PLUS) 28" backrest to horizontal The manual pelvic tilt feature sets the seat angle at 0° position. (horizontal) or 6° (up) position.
  • Page 24 FLEX High-Low Exam Table OPERATION (CONTINUED) Front Drawer Warmer Outlet (Models 5701, 5801, 5701PLUS and (Models 5701, 5801, 5701PLUS and 5801PLUS) 5801PLUS) Models 5701, 5801, 5701PLUS and 5801PLUS are Models 5701, 5801, 5701PLUS and 5801PLUS are equipped with a drawer warmer that is turned on by a equipped with an Outlet (Figure 40).
  • Page 25 FLEX High-Low Exam Table OPERATION (CONTINUED) EasyGlide Mobility Option OPERATION (CONTINUED) (Available option for all PLUS Models) Once EasyGlide is deployed, the table can be rotated and moved around the exam room to accommodate cleaning To engage EasyGlide mobility option (deploy wheels on...
  • Page 26 FLEX High-Low Exam Table OPERATION (CONTINUED) EasyGlide Mobility Option Warnings/ Cautions/Notices WARNING: Fall Hazard The mobility feature is not intended to be used with a patient on the table. WARNING: Pinch Hazard Before and during downward movement, keep personnel and equipment clear of table to avoid personal injury or damage to the equipment.
  • Page 27 Only use the receptacle to supply power to equipment intended to form part of the medical Improper cleaning products used on Brewer tables can electrical system. decrease the life of the table. Always follow Brewer’s Cleaning guidelines. You can view the latest guidelines at Preventative Maintenance brewercompany.com/resources/product-manuals/.
  • Page 28 1/4 turn counterclockwise to remove cap and fuse (Figure 44). Fuse Cap Figure 44. Fuse Cap 4. Replace fuse with Brewer 2102490, 3A 250V fuse. 5. Push new fuse into cap. 6. Push cap with fuse into holder and rotate 1/4 turn clockwise to install.
  • Page 29 FLEX High-Low Exam Table ACCESSORIES Refer to the Brewer website (www.brewercompany.com) for a list of current accessories. POWER CORD OPTIONS NOTICE This table must be used with a Brewer provided power cord. Failure to do so will void the warranty of electrical components.
  • Page 30 Exam Table WARRANTY For Brewer Warranty Information: Registering your Brewer product is easy. Simply go to brewercompany.com/warranty-registration, fill out the information fields and click send. By registering your product today, you are better safeguarding your investment in the future. Document 2102861 RevI...

This manual is also suitable for:

Flex high-low plus

Table of Contents