Back to Contents SAFETY FIRST IMPORTANT: PLEASE READ THIS MANUAL AND SAVE FOR FUTURE REFERENCE WARNINGS: Electrical Shock Hazard Electrical Shock Hazard • Use caution when dealing with any electrical equipment. • Consult a qualified electrician for electrical installation. UNIT SPECIFICATIONS Model Number of Compressor...
Back to Contents STAINLESS STEEL CABINET INSTALLATION Secure the mounting bracket to ground, post, or vertical wall (shed) with electrical service. Place the cabinet adjacent to the electrical service which will power the system. The cabinet has a 6-foot power cord with a plug. DO NOT USE EXTENSION CORDS. Place the cabinet on its side Use a 7/16”...
Back to Contents ASSEMBLY INSTRUCTIONS The following process supports up to 70lbs. For high-accumulation areas such as under inlets, install with caution. The holes on the baseplate (N) can be used to suspend it via chain or cable for added strength.
Page 8
Back to Contents ASSEMBLY INSTRUCTIONS Angle hose barb (R) toward the keyhole Firmly press tubing (A) into the narrower part cutout. Run tubing (A) through the wide hole. of the keyhole to create a strain relief for the Secure it to the barb with the hose clamp (Q). diffuser.
Page 9
Back to Contents ASSEMBLY INSTRUCTIONS Attach the free end of the 2-link chain (F) to Drill 1" deep hole with a 3/8" masonry drillbit. the small strain relief (H) with a hex head Insert concrete anchor (C) with the female screw (J), locknut (K), and washer (L).
Back to Contents TUBING CONNECTION LS-125 & LSH-125 SYSTEMS Seal one tube using the In the second tube, insert Connect SureSink tubing to provided 3/8" hose plug and provided 3/8" barb fitting and exposed side of barb fitting hose clamp. secure using a hose clamp.
Back to Contents FILTER MAINTENANCE Warning! Product surfaces become very hot during operation. Allow compressor to cool before servicing. Disconnect electrical power before performing maintenance. • Check filter monthly. • Failure to maintain clean air filter will lead to excessive heat and premature failure of the compressor.
The system owner assumes all risks of operating the HydraForce Lift Station Agitator during winter months. In climates where temperatures fall below freezing, Kasco recommends insulating the air lines from the compressor cabinet to 3 feet below the lift station/wet well lid. Prevent ice buildup in the lines by using closed cell polyurethane foam to insulate.
Repair Center. You can also email Kasco at support@kascomarine.com. Please include the repair form received from Kasco or your local distributor with the shipment. If no repair form is available, include your name and physical address for return delivery of the repaired compressor and a daytime phone number and/or email address for correspondence regarding the warranty claim.
Please ship according to the instructions provided. Kasco does estimates on repairs at the request of the customer. The request for an estimate should be included in the letter that accompanies the returned compressor and must include a daytime phone number and/or email address.
Back to Contents REPAIR CONTACT FORM • Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention. Kasco Marine • Unit should be cleaned before shipping. 800 Deere Road • Kasco is NOT responsible for shipping damage accrued in Prescott, WI 54021 return shipment.