SECTION 57 8-200-100
4. 04
The wiring for bypass switch assembly
TP327631,
the SAH0 chassis,
and the
terminal is shown in simplified
form on Figure 8.
Refer to 8716WD for a complete schematic
and
to 8566WD for actual wiring information.
(a) The bypass switch, SWl, has four trans-
fer contacts but only three of them are
used.
In the bypass positfori (as shown on
Figure 8), the data set output is fed in at pin
5 on the orange wire,
transferred
to pin 4,
and fed out to the SMD input of the terminal
on the yellow wire.
Since pin 2 is closed to
pin 6, the data output of the SAll0 (white wire)
is connected
to the data input of the SAll0
(red wire).
The white-slate
and white-purple
wires are in series
with the BREAK contact
of the terminal
(if
present) and are tied to.;.
gether at pins 7 and 8. The slate and purple
wires connect to the relay break contact in
the SAll0.
(b)
When SWl is activated,
the data set output
at pin 5 (orange wire) is transferred
to pin
.6 (red wire) where it is supplied to the data
input of the SAl 10.
The data output of the
SAl 10 (white wire) at pin 2 is transferred
to
pin 4 (yellow wire) where it is supplied to the
input of the SMD. This places the SAll0 in
series with the incoming data stream between
the data set and the terminal.
Also, the white-
slate and white-purple
wires at pins 7 and
8
are disconnected
and the break contact of
the SAll0 relay is inserted
between them in
series.
When energized,
this relay opens the
output data line, thereby causing a break to
be generated.
4. 05
The wiring for bypass switch ,and indi-
cator
assembly
TP327632,
the ·SAll0
chassis,
and the terminal
is shown in simplified
form on Figure 9. Refer to 8716WD for a com~
plete schematic
and to 8566WD for actual wiring
information.
(a) The bypass switch, SWl, has four trans-
fer contacts
but only three of them are
used.
In the bypass position
(as shown on
Figure 9), the data set output is fed in at pin
5 on the orange wire, transferred
to pin 4,
and fed out to the SMD input of the terminal
on the yellow wire.
Since pin 2 is closed to
pin 6, the data output of the SAll 0 (white wire)
is connected to the data input of the SAl 1 0
(red wire).
Since the bypass
switch and
indicator assembly does not have break gener-
ation capability,
the white- slate and white-
purple wires are tied back at the terminal.
Page 18
(b)
When SWl is activated,
the· data set out-
put at pin 5 (orange wire) ·is transferred
to pin 6 (red wire) where it is supplied to the
data input of the SAll0.
The data output of
the SA110 (white wire)at
pin 2 is transferred
to pin 4 (yellow wire) where if is supplied to
the input of the SMD. This places the SAl 10
in series with the incoming data stream,
as
for the TP327631
assembly.
The counter
coil, DSl, and the lamp, DSl, are connected
to the relay transfer
contact in the SAll0.
When the relay is energized,
this contact per-
mits the counter to register
the error and the
lamp to light. Depending on the SAll 0 strap-
ping (3. 2 9 and 3. 34), the lamp will flash on
for each error or latch on for the first error
and flash off for each additional error.
For
each flash (on or off) of the lamp, the counter
will register
another count. The reset switch,
SW2, extinguishes
the lamp when the lamp
housing is depressed;
the counter is mechan-
ically reset
to zero by its own pushbutton.
BYPASS SWITCH AND INDICATOR ASSEMBLIES
FOR 35 TYPE SETS
4. 06
Assemblies
TP327633 and TP327634 can
be mounted on 35 type
ASR, KSR,
or
RO
sets. . Two holes are drilled in the upper cover
of the terminal
and the bypass
or indicator
assembly
attached with screws and lockwashers
(Figure 10). A single cable connects the assem-
bly to the electrical
service unit "C" wiring field
and the SAl 10 chassis,
which is placed inside the
pedestal or mounted onanadjacent
wall or table.
4. 07
The wiring for assemblies
TP327633 and
TP327634 is identical to that for assem-
blies TP327631 and TP327632, respectively
(4.04
and 4.05).
BYPASS SWITCH AND INDICATOR A SSE MB LIES
FOR ''DATASPEED"
RECEIVERS
4. 08
Assemblies
TP327637 through TP327640
are for use on DATASPEED receivers.
They are held on the top of the cabinet by means
of two magnets
attached
to the bottom of the
assembly
{Figure 11). Two cables are supplied
to connect the assembly
to the data set and the
SAll0 chassis,
which is placed on a shelf inside
the cabinet.
4. 09
The wiring for bypass switch assembly
TP327640,
the SAll0 chassis,
the ter-
minal, and .the data set is shown in simplified
Need help?
Do you have a question about the SA110 and is the answer not in the manual?