Ardo Melia Instructions For Use Manual

Ardo Melia Instructions For Use Manual

Wearable double electric breast pump
Hide thumbs Also See for Melia:

Advertisement

Quick Links

ardo melia
wearable double electric breastpump
Instructions for use
Instruction
Video

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Melia and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ardo Melia

  • Page 1 Instructions for use Instruction Video...
  • Page 2 Thank you for choosing Ardo...
  • Page 3: Table Of Contents

    Charging your Ardo Melia ........
  • Page 4: Overview

    The Ardo Melia has a soft silicone breast shell and intuitive design to make the entire pumping session more comfortable and convenient. And, as the pump is easy to assemble and discreet, you can take it with you anywhere, allowing you to pump milk at your convenience and maintain your milk supply.
  • Page 5 Ardo Melia is observed, please discontinue use until the parts have been replaced. • If the Ardo Melia is stored at minimum temperature, please wait 2 hours before use to allow it to warm up to room temperature.
  • Page 6: Product Description

    Note: Additional breast shell sizes / inserts and spare parts are available in online shops, and in some countries also from mid- wives, lactation consultants, pharmacies, or drugstores. For wholesale prices contact Ardo directly. Description of LED display and button functionality...
  • Page 7: Getting Started

    To assemble the Ardo Melia, follow the steps below. CAUTIONS: • Make sure that you clean the Ardo Melia as instructed in these instructions for use. • Make sure that you assemble the pump correctly as instructed in these instructions for use.
  • Page 8 If necessary, adjust the size of the funnel using a breast shell insert or a different size of breast shell. Breast shells in size 24 mm and breast shell inserts in size 19 mm are included with the Ardo Melia. Breast shells in size 27 mm and breast shell inserts in size 17 mm are also available for this breastpump (we reserve the right to change this).
  • Page 9 Press the breast shell firmly against the breast, leave no gaps, and make sure your nipples are centered inside the breast shell. Keep the Ardo Melia upright. Be careful not to change the position of the Ardo Melia on the breast; otherwise it will not have suction.
  • Page 10 The Ardo Melia has a built-in memory function: When you turn on the Ardo Melia again, the device automatically enters and up shifts to the working mode and suction levels you used last time. If the Ardo Melia is turned on for the first time, the working mode is Expression mode with suction level one.
  • Page 11 If you experience extreme discomfort or pain while using the Ardo Melia, stop using it and consult your breastfeeding consultant. • Never tilt the Ardo Melia when the milk has reached the maximum line on the milk collector to avoid spillage. Pour the milk into a milk container (bottle or bag) before continuing to pump. •...
  • Page 12: Charging Your Ardo Melia

    The Ardo Melia contains a rechargeable lithium battery and can be used without the adapter connected. The Ardo Melia cannot be operated while charging. • The Ardo Melia has a 3-bar battery indicator. When the power is off or the charger is not connected, the battery indica- tor DOES NOT light up. •...
  • Page 13: Tips For A Successful Pump Session

    WARNINGS • Be careful when removing and cleaning the lip valve, if the lip valve is damaged, the Ardo Melia will not work properly. • To clean the lip valve, please rub it gently in the warm water with a few drops of dish washing liquid. Do not insert any objects into the lip valve, which may cause damage.
  • Page 14 8.1.2 Clean in dishwasher • If you decide to clean pump parts in a dishwasher, be sure to place small items into a closed-top basket or mesh laundry bag. Add soap and if possible, run the dishwasher using hot water and a heated drying cycle. •...
  • Page 15: Troubleshooting

    If you don’t plan to use freshly expressed milk within 4 days, freeze it right away. 9. Troubleshooting This chapter summarizes the most common problems you could encounter with the Ardo Melia. If you are unable to solve the problem with the information below, please contact the local customer service center (in the USA: support@ardo-usa.com).
  • Page 16: Technical Information

    Technical information 10.1 Specifications Power requirements * Only use the charger recommended as below: Charging power: 5Vdc by wall adaptor Power supply Operating power: 3.7Vdc Li-Ion battery Input: 100-240 Vac, 50-60 Hz, 0.4 A-0.2 A Charger specifications Output: DC5 V, 1 A Technology specifications Use environment Home or office use...
  • Page 17 • With other equipment: Use of the Ardo Melia adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, the Ardo Melia and the other equipment should be observed...
  • Page 18: Disposal Information

    The Ardo Melia must accept any interference received, including interference that may cause undesired operation. NOTE The Ardo Melia has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules.
  • Page 19: Symbols Definition

    The warning symbol identifies all instructions that are important for safety. Failure to observe these instructions can lead to injury or damage to the Ardo Melia! When used in conjunction with the following words, the warning symbol stands for: 12.1...
  • Page 20: Warranty Specification

    In order to safeguard the warranty coverage and ensure perfect functioning of the device, the instructions for use must be followed and only Ardo accessories may be used.
  • Page 21 Guidance and manufacturer’s declaration – electromagnetic immunity IEC 60601-1-2 Immunity test Compliance level Test level ±8 kV contact ±8 kV contact Electrostatic discharge (ESD), IEC ±2 kV, ±4 kV, ±8 kV, ±2 kV, ±4 kV, ±8 kV, 61000-4-2 ±15 kV air ±15 kV air Electrical fast transient/burst, IEC Not applicable...
  • Page 22 Radiated Test Compli- Band Modula- Maximum Distance 60601-1-2 Frequency Service ance level (MHz) tion Power (W) Test Level IEC61000- (V/m) (MHz) (V/m) (Test specifica- tions for GSM 800/900, Pulse ENCLO- TETRA 800, modula- SURE 800–960 iDEN 820, tion PORT CDMA 850, 18 Hz IMMUNITY LTE Band 5...
  • Page 24 Distributed by: Distributor USA: Ardo medical AG Ardo medical, Inc. Gewerbestrasse 19 13800 Coppermine Road 6314 Unterägeri 1st Floor Switzerland Herndon, VA 20171, USA www.ardomedical.com 844-411-ARDO (2736) support@ardo-usa.com www.ardo-usa.com...

Table of Contents