nilan Comfort CT150 User Manual
nilan Comfort CT150 User Manual

nilan Comfort CT150 User Manual

Hide thumbs Also See for Comfort CT150:

Advertisement

Quick Links

USER MANUAL
CTS602 LIGHT
BY NILAN
Comfort CT150 / CT200
Gateway
Version 4.20 - 25.06.2024
B24 Comfort CT150-CT200_GB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Comfort CT150 and is the answer not in the manual?

Questions and answers

Summary of Contents for nilan Comfort CT150

  • Page 1 USER MANUAL CTS602 LIGHT BY NILAN Comfort CT150 / CT200 Gateway Version 4.20 - 25.06.2024 B24 Comfort CT150-CT200_GB...
  • Page 2: Table Of Contents

    Power supply ........................................4 Introduction........................................... 4 Documentation........................................ 4 Data plate ......................................... 5 App option Nilan User App ........................................6 Introduction ........................................6 Explanation of main screen items ................................6 Temperature ........................................6 Ventilation ........................................7 Domestic hot water ......................................7 Air humidity ........................................
  • Page 3 Language ........................................23 Alarm list Comfort ..........................................24 Alarm list ........................................24 Product data EU/EC Declaration of Conformity ...................................28 Ecodesign data Comfort CT150 .................................29 Ecodesign data Comfort CT200 .................................30 Disposal The environment - part of the solution ................................31 Ventilation unit ......................................31 Disposal ..........................................31...
  • Page 4: General Information

    The instructions can be downloaded from www.nilan.dk. If you have questions regarding installation and operation of the unit after having read the instructions, please contact your nearest Nilan dealer. A list of Nilan dealers is available on www.nilan.dk. ATTENTION The unit must be started up immediately after installation and connection to the duct system.
  • Page 5: Data Plate

    ATTENTION When contacting Nilan A/S with questions about the product, it is important to have the unit name and serial no. (SN) ready. From this information, the service department can fi nd all information about the unit in question and thus help with information and answer questions about what the unit consists of/contains, and what software is used.
  • Page 6: App Option

    Introduction The following instructions are general and apply to all Nilan ventilation units. Some of the shown functions and settings may therefore not exist on your ventilation unit. The user settings that are applicable to exactly your ventilation unit will more or less correspond to those displayed in the Nilan User App on your phone.
  • Page 7: Ventilation

    Ventilation Ventilation 1. Press “back” to return to the previous page. 2. Here you can set the fan speed level you want. The fan speed level that you have selected may differ from the one displayed on the main screen. This is because the unit is able to override the set fan speed level, e.g.
  • Page 8: Air Humidity

    Air humidity Air humidity 1. Press “back” to return to the previous page. 2. Here you can set the value for low level of humidity between 15– 45 %. 3. Here you can set the fan speed level for low humidity between level 1 – 3. You can also deactivate the function.
  • Page 9: Filter Replacement

    Filter replacement Filter replacement 1. Press “back” to return to the previous page. 2. Here you can set the amount of days between fi lter replacements. 3. Here you can reset the alarm for fi lter replacement. 4. Here you can turn off the ventilation unit before fi lter replacement and turn the unit on again afterwards.
  • Page 10: Control Panel

    Control panel Control panel functions Main screen items Main screen items The main screen of the HMI panel shows the information and the settings options that a user mostly requires. Shows the current room temperature in the house, measured via the extract air. Shows the current fan speed level.
  • Page 11: Main Screen Settings Options

    Main screen settings options Main screen settings options The settings options that are necessary in daily life can all be set on the main screen of the panel. If you press current fan speed level, the set fan speed level will If you press current room temperature, the set room tempe- be displayed.
  • Page 12: Warnings And Alarms

    Warnings and alarms Warning and alarms If the ventilation unit is faulty or an error If you press the symbol, a brief descrip- When the problem has been solved, you occurs, there will be either a warning or tion of the warning or the alarm will be can reset the warning or alarm by pres- an alarm.
  • Page 13: Service And Maintenance

    Generally A ventilation unit from Nilan can last for many years if it is properly serviced and maintained. Ventilation units are often hidden away, and they are therefore rarely given attention in everyday life. But just as you maintain your car, your ventilation unit will need servicing regularly to keep it functioning properly.
  • Page 14: Illustration Of Filter Change

    Illustration of filter change Illustration of fi lter change 1. The unit must be switched off on the control panel 2. The toggle case catch latches are opened on both under OPERATION, which is located under the main sides and the door is tilted down. menu SETTINGS, before opening the door.
  • Page 15: Illustration Of Pollen Filter Change

    Illustration of pollen filter change Illustration of pollen fi lter change 1. The unit must be switched off on the control panel 2. The toggle case catch latches are opened on both under OPERATION, which is located under the main sides and the door is tilted down.
  • Page 16: Annual Maintenance

    Annual maintenance General cleaning General cleaning The ventilation unit should be cleaned on the inside once a year. Dust may escape through the fi lters and potentially mix with moisture from the extract air. WARNING Stop the ventilation unit on the control panel and switch off the power supply for the ventilation unit before you open the front door to the unit.
  • Page 17: Heat Exchanger

    Heat exchanger Heat exchanger The counterfl ow heat exchanger is a central part of the ventilation unit. It heats up the cold outdoor air with energy from the warm extract air. To maintain a high level of heat recovery, it is important that the heat exchanger is not clogged with dirt. Experience indicates that it should not be necessary to lift out and clean the heat exchanger every year.
  • Page 18: User Settings

    User settings Ventilation settings Turn off the ventilation unit Turn off the ventilation unit If you need to open the doors to the ventilation unit in connection with servicing or fi lter replacement, remember to turn off the ventilation unit. You do this under the menu item “Operation”. When the ventilation unit is off, this icon is displayed on the main screen of the control panel in the top righthand corner.
  • Page 19: Alarm

    Alarm Alarm You can read off warnings and alarms under the “Alarm” menu item. This is also where you reset them once the problem has been solved. If an alarm or a warning is active, the alarm icon will be displayed in the upper righthand corner of the control panel.
  • Page 20: Date/Time

    Date/time Date/time It is important to set date and time correctly. It makes it easier to trace potential faults when an error is being reported. When logging data, it is important to be able to follow the history. You set the time in the settings menu. >...
  • Page 21: Heating Element

    Heating element Heating element You will only have this menu item if an electrical after-heating element or a water after-heating element has been installed, and if it has been activated in “Service settings”. ATTENTION An after-heating element is not included as standard. However, you can order it as an additional extra, and it can also be retrofi tted.
  • Page 22: Co 2 Control

    control control This menu is only displayed if a CO -sensor has been installed, and the function has been chosen under Service settings. ATTENTION A CO sensor is not a standard part of all ventilation units, but may be purchased as an accessory. If the number of people using a building varies considerably, controlling ventilation through the CO level in the extract air may be a good solution.
  • Page 23: Temperature Regulation

    Temperature regulation Temperature regulation If you have not installed an after-heating element, use the settings to control the bypass damper. It is necessary to install an after-heating element if you want to control the supply air temperature and for it to contribute towards the heating of the dwelling.
  • Page 24: Alarm List

    Alarm list CTS602 HMI / CTS602i HMI Comfort Alarm list Alarm list The following list applies to ventilation units with either CTS602 HMI, CTS602Light or CTS602i HMI control. The events are divided into the following categories: Warning Operation continues, but an incident has occurred that should be kept in mind. Alarm Operation is partially or completely stopped as it is a critical fault that needs immediate attention.
  • Page 25 OVERTEMP Overheat EK: Check that the circulation pump is working Electric boiler overheating (Tmax+10 °C) Check that the circulation of the central heating system is not blocked by e.g. a closed ball valve, or because all the actuators are closed on the underfl...
  • Page 26 s working T WATER Hot water temp. failure: Contact service. Domestic hot water heating not possible. entral heating T HEAT Central heat.temp.failure: Contact service. sed ball valve, Central heating temperatur failure. osed on the 27-60 TxSHORT/ Tx shortcut/disconnect: Register which sensor (Tx) is faulty and contact OPEN One of the temperature sensors has either service.
  • Page 27 If there has been no smoke or fi re in the building: TECTOR NIL-139: Check the smoke detector (not a Nilan product). Via a service menu, DI8 can be confi gured for Fire Thermostat or Smoke Detector, respec- tively. This alarm is displayed instead of the...
  • Page 28: Product Data

    Product data EU/EC Declaration of Conformity EU/EC Declaration of Conformity...
  • Page 29: Ecodesign Data Comfort Ct150

    Ecodesign data Comfort CT150 Ecodesign data Comfort CT150 Comfort CT150 175 m ENERGIA · · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE ENERGI 2016 1254/2014 SEC* average climate -42.7 kWh/(m SEC* cold climate -82.1 kWh/(m SEC* warm climate -17.5 kWh/(m...
  • Page 30: Ecodesign Data Comfort Ct200

    An alarm on the user panel appears when fi lters need changing. Attention: To maintain the performance and energy effi ciency of the unit it is very important to change fi lters regularly. Disassembly instructions www.nilan.dk * Specifi c energy consumption AEC - annual electricity consumption 235 kWh/year (100 m...
  • Page 31: Disposal

    The environment - part of the solution At Nilan A/S we recognize our responsibility in minimizing the environmental impact of our products. We consider the impact on the environment in all aspects of production, operation and subsequent disposal. We recognize our responsibility in minimizing consumption of resources.
  • Page 32 25 St Leonards Road, Horsham RH13 6EH West Sussex Tel: +44 (0) 14 03 56 30 45 service@slservicesgroup.com info@slservicesgroup.com www.slservicesgroup.com Ireland: Nilan Ireland Ballylahive, Abbeydorney Tel: +353 (0) 87 97 98 361 maurice@nilan.ie www.nilanireland.ei Nilan A/S Nilanvej 2 8722 Hedensted Danmark Tlf.

This manual is also suitable for:

Comfort ct200

Table of Contents