MP Filtri FHM050 Installation, Service And Maintenance Instructions

High pressure filters

Advertisement

Quick Links

T
PASSION
PERFORM
HIGH
PRESSURE
FILTERS
INSTALLATION,
SERVICE AND
MAINTENANCE
MANUAL
AND SAFETY
INSTRUCTIONS
INSTRUCTIONS
FHM050
FHM050
EN
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FHM050 and is the answer not in the manual?

Questions and answers

Summary of Contents for MP Filtri FHM050

  • Page 1 HIGH PRESSURE FILTERS INSTALLATION, SERVICE AND MAINTENANCE MANUAL AND SAFETY INSTRUCTIONS INSTRUCTIONS FHM050 FHM050 PASSION PERFORM...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Page Description General warnings Tools Handling Dimensional drawings Installation Commissioning Standard maintenance Filter element replacement Special maintenance Clogging indicator (or plug) replacement Seals replacement Instructions for use in explosive atmospheres Regulations Spare parts list Ordering code 13.1 Filter / Housing / Bowl 13.2 Filter element...
  • Page 4: Description

    - Connect the filter with an anti-loosening system and regularly check the condition of the connection - The declared performances and the safety of the product are only guaranteed when MP Filtri original spare parts are used - Warranty is only effective if MP Filtri original spare parts are used.
  • Page 5: Handling

    FHM050 Handling - The unit is shipped in a cardboard box with dimensions depending on the order - The handling must be carried out in accordance with the laws in force in the country of use of the product - Handle the product with care, avoid impacts - Store in a dry and frost-free room - The unit should be stored in a suitable location away from the production area when not in use.
  • Page 6: Dimensional Drawings

    Dimensional drawings FHM050 Filter length [mm] Recommended Ø68 clearance space Drain plug for maintenance only length 5 Connection for differential indicator T2 plug not included Nr. 4 holes High Pressure filters...
  • Page 7: Installation

    FHM050 Parts identification Parts identification FHM050-065 Item Description Clogging indicator connection Installation Identification plate Clogging indicator connection Identification plate Drain plug - Check that the system working pressure does not exceed the maximum working pressure of the filter. The maximum working pressure of the filter is shown on the identification plate...
  • Page 8: Standard Maintenance

    - (Fig. 2) Drain the operating fluid from the bottom of the bowl into the collection vessel - (Fig. 3) Screw the drain plug in referring to the tightening torque table in paragraph 3 Smontaggio Svuotamento Smontag FHM050 leto contenitore contenitore element...
  • Page 9: Special Maintenance

    FHM050 Smontaggio Svuotamento Smontaggio Montaggio Montaggio contenitore contenitore elemento elemento contenitore aggio Smontaggio Svuotamento Smontaggio Montaggio Montaggio renaggio contenitore contenitore elemento elemento contenitore taggio Smontaggio Smontaggio Smontaggio Svuotamento Svuotamento Svuotamento Smontaggio Smontaggio Smontaggio Montaggio Montaggio Montaggio Montaggio Montaggio Montaggio drenaggio...
  • Page 10: Seals Replacement

    - (Fig. 15) Screw the drain plug in referring to the tightening torque table in paragraph 3 - (Fig. 16) If no drain plug is provided, unscrew the filter bowl after placing a vessel to collect the operating fluid Filtro Smontaggio Svuotamento FHM050 completo contenitore contenitore Smontaggio...
  • Page 11 FHM050 Smontaggio Sost. guarnizioni Montaggio Sost. guarnizioni Sost. guarnizioni Svuotamento Smontaggio Montaggio Montaggio corpo indicatore bypass connettore manifold elemento+contenitore contenitore elemento elemento contenitore Svuotamento Smontaggio Smontaggio Smontaggio Svuotamento Svuotamento Montaggio Smontaggio Smontaggio Montaggio Montaggio Montaggio Montaggio Montaggio contenitore contenitore contenitore...
  • Page 12: Instructions For Use In Explosive Atmospheres

    MP FILTRI has carried out a voluntary certification of a part of the product range in compliance with directive 2014/34/EU, in order to guarantee an appropriate degree of safety in these particular conditions.
  • Page 13: Spare Parts List

    Spare parts list FHM050 FHM050 12. Spare parts list Item Quantity Description Designation / Ordering code Complete filter Housing See “Ordering Code” table Bowl Assembly Filter element Clogging indicator Item Q.ty Description Designation / ordering code Seals kit Complete filter...
  • Page 14: Ordering Code

    3 µm Inorganic microfiber 6 µm Inorganic microfiber 10 µm Inorganic microfiber 16 µm Inorganic microfiber 25 µm Wire mesh 25 µm Valves Element ∆p 20 bar • • 210 bar • • Execution MP Filtri standard Customized High Pressure filters...
  • Page 15: Filter Element

    25 µm M25 Wire mesh 25 µm Seals Element ∆p 20 bar 210 bar Execution MP Filtri standard Customized CLOGGING INDICATORS Electrical differential indicator Electrical differential indicator Electrical / visual differential indicator Electrical / visual differential indicator Electrical differential indicator...
  • Page 16: Troubleshooting

    14. Troubleshooting 14.1 MISUSE OF THE PRODUCT This product should be connected to a hydraulic line; this must not exceed upper pressure limit of the product. his product should follow all standard operating procedures previously set at the operating location as well as the procedures required by the manufacturer.
  • Page 17 NOTES High Pressure filters...
  • Page 18 NOTES High Pressure filters...
  • Page 19 All data, details and words contained in this publication are provided for use by technically qualifi ed personnel at their discretion, without warranty of any kind. MP Filtri reserves the right to make modifi cations to the models and versions of the described products at any time for both technical and/or commercial reasons.
  • Page 20 WORLDWIDE NETWORK CANADA CHINA FRANCE GERMANY INDIA SINGAPORE UNITED ARAB EMIRATES UNITED KINGDOM ITALY PASSION PERFORM mp ltri.com...

Table of Contents