MP Filtri FHM320 Installation, Service And Maintenance Instructions

High pressure filters

Advertisement

Quick Links

T
PASSION
PERFORM
HIGH
PRESSURE
FILTERS
INSTALLATION,
SERVICE AND
MAINTENANCE
MANUAL
AND SAFETY
INSTRUCTIONS
INSTRUCTIONS
FHM320
FHM320
EN
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FHM320 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MP Filtri FHM320

  • Page 1 HIGH PRESSURE FILTERS INSTALLATION, SERVICE AND MAINTENANCE MANUAL AND SAFETY INSTRUCTIONS INSTRUCTIONS FHM320 FHM320 PASSION PERFORM...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Page Description General warnings Tools Handling Dimensional drawings Installation Commissioning Standard maintenance Filter element replacement Special maintenance Clogging indicator (or plug) replacement Seals replacement Instructions for use in explosive atmospheres Regulations Spare parts list Ordering code 13.1 Filter / Housing / Bowl 13.2 Filter element...
  • Page 4: Description

    - Connect the filter with an anti-loosening system and regularly check the condition of the connection - The declared performances and the safety of the product are only guaranteed when MP Filtri original spare parts are used - Warranty is only effective if MP Filtri original spare parts are used.
  • Page 5: Handling

    FHM320 Handling - The unit is shipped in a cardboard box with dimensions depending on the order - The handling must be carried out in accordance with the laws in force in the country of use of the product - Handle the product with care, avoid impacts - Store in a dry and frost-free room - The unit should be stored in a suitable location away from the production area when not in use.
  • Page 6: Dimensional Drawings

    Length 4 Ø101 Drain plug Recommended clearance space Connection for for maintenance differential indicator T2 plug Recommended clearance space for maintenance Nr. 6 holes FHM320 Connection for differential indicator [mm] T2 plug not included Filter Execution length [mm] High Pressure filters...
  • Page 7: Installation

    Parts identification Parts identification FHM320 FHM320 Item Description Clogging indicator connection Installation Identification plate Drain plug Clogging indicator connection Identification plate Drain plug - Check that the system working pressure does not exceed the maximum working pressure of the filter.
  • Page 8: Standard Maintenance

    Standard maintenance FILTER ELEMENT REPLACEMENT The clogging indicator monitors the conditions of the filter element. The alarm signal shown by the differential indicator during the normal working conditions (pressure, temperatures …) means that the filter element needs to be replaced. - Check the availability of the right spare filter element by comparing the part number shown on the element with that shown on the filter name plate or spare parts list - For the disassembly and the assembly of the parts, please refer to the tools table in paragraph 3...
  • Page 9 FHM320 Montaggio Filtro Smontaggio Drenaggio EXECUTION P01 (Standard) completo tappo di drenaggio tappo di drenaggio olio filtro - From length 4 the bowl consists of two parts whose thread are locked Filtro Smontaggio Drenaggio Montaggio Filtro Smontaggio Drenaggio Montaggio completo...
  • Page 10 Legenda li: Lev Blu - spess. 0,3 Lev Rosso - spess. 0,6 Lev Azzurro - spess. 1,2 Montaggio Legenda li: Legenda li: Legenda li: aggio tappo di drenaggio Lev Blu - spess. 0,3 Lev Blu - spess. 0,3 Lev Blu - spess. 0,3 Lev Rosso - spess.
  • Page 11: Special Maintenance

    P02 elemento P01 contenitore P01 elem FHM320 Special maintenance CLOGGING INDICATOR (OR PLUG) REPLACEMENT - Check the availability of the right spare parts by comparing the part numbers shown on them with that shown on the filter name plate or spare parts list...
  • Page 12 Smontaggio Montag ggio Svuotamento Smontaggio Montaggio Montaggio Smontaggio Montaggio tappo contenitore P02 tappo conten e P01 contenitore P01 elemento P01 elemento P01 contenitore P01 elemento P02 elemento P02 Filtro Smontaggio Montaggio Drenaggio completo tappo di drenaggio tappo di drenaggio olio filtro Filtro Smontaggio Montaggio...
  • Page 13 Smontaggio Montaggio elemento P01 elemento P01 contenitore P01 tappo contenitore P02 elemento P02 elemento P02 tappo contenitore P02 FHM320 Legenda li: Lev Blu - spess. 0,3 Lev Rosso - spess. 0,6 Lev Azzurro - spess. 1,2 Drenaggio Drenaggio Montaggio Montaggio...
  • Page 14 Smontaggio Montaggio Montaggio Smontaggio Montaggio tappo contenitore P02 tappo contenitore P02 o P01 contenitore P01 elemento P02 elemento P02 Smontaggio Smontaggio Montaggio Montaggio Montaggio Montaggio Montaggio Smontaggio Smontaggio Montaggio Montaggio tappo contenitore P02 tappo contenitore P02 tappo contenitore P02 tappo contenitore P02 elemento P01 contenitore P01 contenitore P01...
  • Page 15 FHM320 High Pressure filters...
  • Page 16: Instructions For Use In Explosive Atmospheres

    MP FILTRI has carried out a voluntary certification of a part of the product range in compliance with directive 2014/34/EU, in order to guarantee an appropriate degree of safety in these particular conditions.
  • Page 17: Spare Parts List

    FHM320 Spare parts list FHM320 12. Spare parts list Item Quantity Description Designation / Ordering code Complete filter Housing Item Q.ty Description Designation / ordering code See “Ordering Code” table Bowl Assembly Filter element Complete filter See ordering table Housing...
  • Page 18: Ordering Code

    Inorganic microfiber 25 µm Wire mesh 25 µm Valves Element ∆p 20 bar • • Filter Length 210 bar • • Execution MP Filtri standard • • • • Maintenance from the • bottom of the housing Customized High Pressure filters...
  • Page 19: Filter Element

    25 µm M25 Wire mesh 25 µm Seals Element ∆p 20 bar 210 bar Execution MP Filtri standard Customized CLOGGING INDICATORS Electrical differential indicator Electrical differential indicator Electrical / visual differential indicator Electrical / visual differential indicator Electrical differential indicator...
  • Page 20: Troubleshooting

    14. Troubleshooting 14.1 MISUSE OF THE PRODUCT This product should be connected to a hydraulic line; this must not exceed upper pressure limit of the product. his product should follow all standard operating procedures previously set at the operating location as well as the procedures required by the manufacturer.
  • Page 21 NOTES High Pressure filters...
  • Page 22 NOTES High Pressure filters...
  • Page 23 All data, details and words contained in this publication are provided for use by technically qualifi ed personnel at their discretion, without warranty of any kind. MP Filtri reserves the right to make modifi cations to the models and versions of the described products at any time for both technical and/or commercial reasons.
  • Page 24 WORLDWIDE NETWORK CANADA CHINA FRANCE GERMANY INDIA SINGAPORE UNITED ARAB EMIRATES UNITED KINGDOM ITALY PASSION PERFORM mp ltri.com...