AMBERAIR COMPACT RIS 12002500 P EKO 3.0
EN
MOUNTING AND INSTALLATION INSTRUCTION

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AmberAir Compact RIS EKO 3.0 1200 PE 3.0 and is the answer not in the manual?

Questions and answers

Summary of Contents for Salda AmberAir Compact RIS EKO 3.0 1200 PE 3.0

  • Page 1 AMBERAIR COMPACT RIS 12002500 P EKO 3.0 MOUNTING AND INSTALLATION INSTRUCTION...
  • Page 2: Table Of Contents

    1. CONTENT 2. SYMBOLS AND MARKING 3. SAFETY INSTRUCTIONS AND PRECAUTIONS 4. INFORMATION ABOUT THE PRODUCT 4.1. DESCRIPTION 4.2. DIMENSIONS AND WEIGHT 4.3. TECHNICAL DATA 4.4. OPERATING CONDITIONS 4.5. STANDARD PACKAGE OF COMPONENTS 4.6. DESCRIPTION OF COMPONENTS 5. INSTALLATION 5.1. RECEPTION OF GOODS 5.2.
  • Page 3: Symbols And Marking

    2. SYMBOLS AND MARKING Warning – pay attention Additional information Apply the auxiliary label on the unit (on an easily accessible location) or on the dashed location of the technical manual in order to keep the im- portant information about the unit. Figure 2.1.
  • Page 4: Safety Instructions And Precautions

    3. SAFETY INSTRUCTIONS AND PRECAUTIONS Read these instructions very carefully before installing and using this equipment. Installation, connection and maintenance should be carried out Main safety rules Danger • of the device have stopped. • Make sure that the fans are not accessible through air ducts or branch openings. •...
  • Page 5: Information About The Product

    4. INFORMATION ABOUT THE PRODUCT 4.1. DESCRIPTION package. Not suitable for operation in pools, saunas and other similar premises. 4.2. DIMENSIONS AND WEIGHT Figure 4.2.1. AmberAir Compact RIS 1200 P EKO 3.0 dimension Figure 4.2.2. AmberAir Compact RIS 1900-2500 P EKO 3.0 dimension AmberAir Compact RIS 1200-2500 P EKO 3.0 v2023.1 EN |...
  • Page 6: Technical Data

    AmberAir Compact 1200 1200 1200 1200 1900 1900 1900 1900 2500 2500 2500 2500 RIS EKO 3.0 PE 3.0 PE 6.0 PE 9.0 PE 3.0 PE 6.0 PE 12.0 PE 4.5 PE 9.0 PE 18.0 [mm] 1550 1750 1850 [mm] 1397 1850 1950...
  • Page 7 AmberAir Compact RIS EKO 3.0 1900 PE 3.0 1900 PE 6.0 1900 PE 12.0 1900 PW EXHAUST AIR FAN phase/voltage [50 Hz/VAC] ~1, 230 ~1, 230 ~1, 230 ~1, 230 [kW/A] 0,47/2,04 0,47/2,04 0,47/2,04 0,47/2,04 speed [min 2530 2530 2530 2530 control input [VDC]...
  • Page 8: Operating Conditions

    4.4. OPERATING CONDITIONS AMBERAIR COMPACT RIS EKO 3.0 1200 PE/PW 1900 PE/PW 2500 PE/PW Minimum outdoor air temperature Maximum outdoor air temperature Minimum extracted air temperature Maximum extracted air temperature Maximum extracted air relative humidity Minimum ambient air temperature Maximum ambient air temperature Installation Indoor Indoor...
  • Page 9: Installation

    5. INSTALLATION 5.1. RECEPTION OF GOODS Each device is carefully checked before transportation. When receiving the goods, checking the devices for any damage made during transporta- tion is recommended. If any damage to the unit is observed, immediately contact the representatives of a transport company. Please inform the representative of the manufacturer, if any deviation of the device is noticed.
  • Page 10: Unpacking

    L1>L2 Figure 5.2.2. Lifting by forklift AmberAir Compact RIS 1900-2500 P EKO 3.0 In order to prevent damage to the casing, only a product placed on a pallet should be lifted. Figure 5.2.3. Lifting AmberAir Compact RIS 1200 P EKO 3.0 Figure 5.2.4.
  • Page 11: Piping And Instrumentation Diagram

    Figure 5.3.1. Unpacking AmberAir Compact RIS 1200 P EKO 3.0 Figure 5.3.2. Unpacking AmberAir Compact RIS 1900-2500 P EKO 3.0 5.4. PIPING AND INSTRUMENTATION DIAGRAM * KE1 - only in electrical version; * KV1 - used in water version; ** Possible to control. AmberAir Compact RIS 1200-2500 P EKO 3.0 v2023.1 EN |...
  • Page 12: Mounting

    THE LIST OF COMPONENTS Plate heat exchanger Supply air fan Exhaust fan Exhaust air temperature sensor Supply air temperature sensor Extract air temperature and humidity sensor sensor Computer Electric heater* By-pass damper Outdoor air damper actuator Exhaust air damper actuator Outdoor air temperature sensor Ventilated premises MB-Gateway...
  • Page 13: Unit Placing And Mounting Positioning Requirements

    5.5.1. UNIT PLACING AND MOUNTING POSITIONING REQUIREMENTS 1,5xL 5.5.2. CEILING-MOUNTING OF THE UNIT Figure 5.5.2.1. Ceiling-mounting of the unit α ⌀D Figure 5.5.2.2. Drainage system installation (øD=150 mm) 5.6. CONNECTION OF THE AIR DUCT • • • and noise level, you can increase the diameter. •...
  • Page 14: Connection Of The Unit To Electric Network

    • Air ducts are often mistakenly connected in inappropriate location. The ventilation units bear the labels indicating the correct air duct connection "DIMENSIONS AND WEIGHT". 5.7. CONNECTION OF THE UNIT TO ELECTRIC NETWORK • • • • The unit must be earthed according to electrical equipment installation regulation. •...
  • Page 15: Maintenance

    6. MAINTENANCE 6.1. SAFETY INSTRUCTION Unplug the unit from the mains before opening the door (disconnect the power plug from the outlet or in case a automatic 6.2. GENERAL RECOMMENDATIONS FOR VENTILATION SYSTEM MAINTENANCE COMPONENT DURING START-UP AT LEAST EVERY 6 MONTHS Filters device indications.
  • Page 16: Filters Maintenance

    6.4. FILTERS MAINTENANCE direction. tion manual or on our website www.salda.lt 6.5. FAN MAINTENANCE • • The fan should be inspected and cleaned at least once per year. • • Proceed to maintenance and repair after any fan rotation is stopped.
  • Page 17: Heater Maintenance

    6.7. HEATER MAINTENANCE • • • • • If necessary, electric heater can be removed. Disconnect the electrical connector from the heater and remove the heater. 6.8. CONTROL BOARD MAINTENANCE • • • • AmberAir Compact RIS 1200-2500 P EKO 3.0 v2023.1 EN |...
  • Page 18: Control

    Modbus RTU (RS485) MB-GATEWAY + WIFI router SALDA AIR mobile application ST-SA-Control BMS over Modbus TCP/IP FLEX BMS over BACnet TCP/IP 7.2. DEVICE FUNCTIONS cation and SALDA AIR mobile application. | EN AmberAir Compact RIS 1200-2500 P EKO 3.0 v2023.1...
  • Page 19: Connection Of Accessories

    8. CONNECTION OF ACCESSORIES 8.1. 8.2. EXTERNAL CO /PRESSURE SENSORS /PRESSURE (input 0-10 VDC) sensors Sensors connection: detection. The CO transmitter is installed in the extract air duct or room. 8.3. ROOM CO TRANSMITTER INSTALLATION RECOMMENDATION 5 0 c m i n . min.
  • Page 20: Concentration According To Pettenkofer Limit

    8.4. CONCENTRATION ACCORDING TO PETTENKOFER LIMIT 8.5. CONNECTION OF SUPPLY AND EXTRACT AIR DAMPERS Spring-return actuators. Wiring diagram for AmberAir Compact RIS PE EKO 3.0 M2, M3 – Open/Close damper actuators. Upon activation of outputs X16:17, X16:20 the dampers shall open, Upon activation of outputs X16:16, X16:19 the dampers shall close.
  • Page 21: Connection Of Remote Control Panel Or Modbus

    8.6. CONNECTION OF REMOTE CONTROL PANEL OR MODBUS 8.7. WATER HEATER CIRCULATION PUMP AND VALVE ACTUATOR Compact RIS PW EKO 3.0 units). Wiring diagram 8.8. RECOMMENDED SCHEME FOR CONNECTION OF INTERNAL AND EXTERNAL COMPONENTS By-pass air damper actuator. Supply air fan EC. Outdoor air damper actuator.
  • Page 22 AmberAir Compact RIS 1200 PE 3.0 EKO 3.0 | EN AmberAir Compact RIS 1200-2500 P EKO 3.0 v2023.1...
  • Page 23 AmberAir Compact RIS 1200 PE 6.0-9.0 EKO 3.0 AmberAir Compact RIS 1200-2500 P EKO 3.0 v2023.1 EN |...
  • Page 24 AmberAir Compact RIS 1200 PW EKO 3.0 | EN AmberAir Compact RIS 1200-2500 P EKO 3.0 v2023.1...
  • Page 25 AmberAir Compact RIS 1900 PE 3.0 EKO 3.0 AmberAir Compact RIS 1200-2500 P EKO 3.0 v2023.1 EN |...
  • Page 26 | EN AmberAir Compact RIS 1200-2500 P EKO 3.0 v2023.1...
  • Page 27 AmberAir Compact RIS 1900-2500 PW EKO 3.0 AmberAir Compact RIS 1200-2500 P EKO 3.0 v2023.1 EN |...
  • Page 28: Possible Faults And Troubleshooting

    9. POSSIBLE FAULTS AND TROUBLESHOOTING FAILURE CAUSE EXPLANATION / CORRECTIVE ACTIONS No supply voltage Unit is not operating leakage relay is active (if installed by the installer) matic protection Check if fans are rotating Air supply heater or pre-heater is not operat- ing or malfunctioning (if installed) Manual safety device is activated MUST be contacted to identify and eliminate...
  • Page 29: Ecodesign Data Table

    10. ECODESIGN DATA TABLE 1200 PE 3.0 1200 PE 6.0 1200 PE 9.0 1200 PW AMBERAIR COMPACT RIS EKO 3.0 Declared typology bidirectional bidirectional bidirectional bidirectional Type of drive Variable Variable Variable Variable Type of HRS recuperative recuperative recuperative recuperative 80,2 80,2 80,2...
  • Page 30 AMBERAIR COMPACT RIS EKO 3.0 2500 PE 4.5 2500 PE 9.0 2500 PE 18.0 2500 PW Declared typology bidirectional bidirectional bidirectional bidirectional Type of drive Variable Variable Variable Variable Type of HRS recuperative recuperative recuperative recuperative 80,4 80,4 80,4 80,4 /s ] 0,64 0,64...
  • Page 31: Declaration Of Conformity

    11. DECLARATION OF CONFORMITY Manufacturer SALDA, UAB LT-78109 Šiauliai, Lithuania Tel.: +370 41 540415 www.salda.lt AmberAir Compact RIS * EKO 3.0 Machinery Directive 2006/42/EC EMC Directive 2014/30/EU Low Voltage Directive 2014/35/EU Ecodesign Directive 2009/125/EC RoHS 2 Directive 2011/65/EU Ecodesign requirements for ventilation units Nr. 1253/2014 Energy labeling of residential units Nr.
  • Page 32: Warranty

    12. WARRANTY date. such damage. damaged by installing the control system. 4.1. mechanical damage; 4.2. damage caused by entering outside objects, materials, liquids; lation and mounting regulations, deliberate or careless users or third-party behavior. days and deliver the equipment to manufacturer. Delivery costs should be covered by customer. Manufacturer reserves the right to change this technical passport any time without prior notice, if some typographic errors or inaccurate information is found, as well as after improving the apps and/or the devices.
  • Page 33 AmberAir Compact RIS 1200-2500 P EKO 3.0 v2023.1...
  • Page 34 AmberAir Compact RIS 1200-2500 P EKO 3.0 v2023.1...
  • Page 35 AmberAir Compact RIS 1200-2500 P EKO 3.0 v2023.1...
  • Page 36 Heat-exchanger cleaning Every 3-4 Filter replacement months** Look at the product label. ** - At least. NOTE. The customer shall be required to complete the Product Maintenance Table. MANUALS IN OTHER LANGUAGES https://select.salda.lt/ https://select.salda.lt/ https://select.salda.lt/ https://select.salda.lt/ https://select.salda.lt/ file/aa-compact-ris1200- file/aa-compact-ris1200- file/aa-compact-ris1200- file/aa-compact-ris1200-...