For Slider Casement Air Conditioners
NOTE:
These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash,
or installation in a metal CASEMENT window. Modification may be necessary when installing in windows made
differently than those shown in these instructions.
A high window accessory kit is available for window heights up to 62" (1575mm). Part # EA103W.
Electrical Shock and Personal Injury Hazard
Electrical ground is required on this appliance.
DO NOT ground to a gas line.
If cold water pipe is interrupted by plastic,
non-metallic gaskets, or other insulating
materials, DO NOT use for grounding.
Check with a qualified electrician if you are in
doubt as to whether the appliance is properly
grounded.
DO NOT modify power supply cord plug. If it
does not fit outlet, have a proper outlet
installed by a qualified electrician.
DO NOT have a fuse in the neutral or
grounding circuit. A fuse in the neutral, or
grounding circuit could result in an elecrtrical
shock.
DO NOT use an extension cord with this
appliance.
Failure to follow these instructions could result in
electrical shock, serious injury, or death.
Installation Instructions

Meeting Electrical Requirements

WARNING

TABLE OF CONTENTS

SUBJECT
OBSERVE ALL LOCAL GOVERNING CODES
AND ORDINANCES.
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD
GROUNDING PRONG.
NOTE:
If codes permit, and a separate
grounding wire is used; it is recommended that a
qualified electrician determine that the grounding
path is adequate and not interrupted by plastic,
non-metallic gaskets, or other insulating materials.
RECEPTACLE WIRING
Receptacle wiring should be a minimum of 14
gauge. Use copper wire only. It is your responsibility
to provide proper and adequate receptacle wiring,
installed by a qualified electrician.
ELECTRICAL REQUIREMENTS
A 115 volt (103.5 minimum, 126.5 maximum), 60
Hertz, AC only, 15 ampere fused electrical supply
is required. A time delay fuse or time delay circuit
breaker is also required. A separate circuit, serving
only this appliance, MUST be provided.
PAGE
1
2
2
4
7
8
P/N 220215A055

Advertisement

loading

Summary of Contents for Frigidaire GAK085Q7V - GIBSON 8000BTU 115V 6.7A 10.0E3 SPD 4 WAY AIR DIRECTION8

  • Page 1: Table Of Contents

    CASEMENT window. Modification may be necessary when installing in windows made differently than those shown in these instructions. A high window accessory kit is available for window heights up to 62" (1575mm). Part # EA103W. TABLE OF CONTENTS...
  • Page 2: Electrical Connection

    Because this unit weighs about 88 to 105 pounds, For brick or cement building construction: It may it is recommended that you have someone help be necessary to put a wood stool strip under AC, for you when install your new unit, and that you both mounting purposes.
  • Page 3 Height measurement must be of a clear height opening above mounting platform. In some cases, 39 / inches due to a variety of stop and track arrangements, the maximum Height above dimensions may vary slightly. If necessary, installation can be made by alternating window jambs.
  • Page 4: Installing Unit In A Sliding Window

    Choose a window that allows the cooled air to flow freely and directly into room(s) you wish to cool. Remember, it is difficult to move air around corners. Also, choose a window that is within 6 feet of an electrical outlet. (See Meeting Electrical Requirements/Receptacle wiring needs.) Do not use an extension cord.
  • Page 5 4. Peel off protective backing from track seal. Apply Apply track seal to window side seal to room side of window track. Center of seal strip of track. should coincide with the line marked in Step 2. The two screw holes drilled in Step 3 should be directly above seal strip in the inner track.
  • Page 6 10. Clamp plastic window panel between a board and a work table, and cut along cutting line with a fine tooth saw. Remove any burrs with a file. Fastening Side Channels 11. Fasten side channels to the sides of the AC using 3 screws (Item 17) per channel.
  • Page 7: Alternate Window Jamb Applications

    16. Slide inner window sash firmly against side of the cabinet. Make sure not to peel the seal strips from the window track and cabinet side channels. If the panel frame does not fit snugly to the inner window sash, secure the panel frame to the sash...
  • Page 8: Installing Unit In A Casement Window

    If the window cannot open far enough (more than 15-1/2 inches) for the cabinet to clear the window, remove the window entirely by drilling out the rivets. Bolts can serve as the pivots in the future. To avoid crank handle and window clearance problems, the unit can be installed in a stationary sash section.
  • Page 9 8. Clamp the plastic window panel between a subtract board and a work table, and cut along the cutting line 20 / inches. with a fine tooth saw. Remove any burrs with a file. 9. Fasten the side channels to the sides of the unit using three screws (Item 17) per channel.
  • Page 10 Remove the protective backing and apply it to the rear side of the cabinet side channels, starting just below the panel frame assembly. Pinch off excess length so the seal is even with the bottom of the cabinet side channel. Apply weather...