Leviton ConTech SpecFlex Series Installation Instructions
Leviton ConTech SpecFlex Series Installation Instructions

Leviton ConTech SpecFlex Series Installation Instructions

Architectural strip light dry location

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS
The important safeguards and instructions here are not meant to cover all possible conditions and situations that may occur.
• WARNING: RISK OF FIRE AND ELECTROCUTION
• WARNING: TO AVOID FIRE, SHOCK OR DEATH, disconnect power at circuit breaker
before installing or servicing device
• TO AVOID SHOCK OR ELECTROCUTION, product must be grounded
• READ AND SAVE THESE INSTRUCTIONS FOR LATER USE
• Product should be installed by a qualified electrician
• All electrical connections must be in accordance with local and National Electrical
Code (NEC) standards.
• Product must be mounted in locations and at heights and in a manner consistent with
its intended use, in compliance with National Electrical Code and local codes and
where it will not readily be subject to tampering by unauthorized personnel
• Driver is to be installed in accordance with Article 450 of the National Electric Code
• Prior to installation, check the label and ensure the Driver has the proper input voltage
and wattage for the job
• NOTE: DO NOT Connect Strip Light directly to line voltage power
• NOTE: Always test Strip Light operation before installing
Connect to power supply to ensure it is working properly and no damage
has occurred during shipping
• Power Supply is selected based on the power and length of the selected
Strip Light and run length
NOTE: Ensure the Power Supply load is 30% higher than the strip's power
• Ensure Power Supply is compatible with the selected Strip Light model
and wattage, plus the anticipated run length
• When the selected Strip Light power is over 4W/Ft, it is advised to install
the strip in an Aluminum Mounting Channel which helps with heat
dissipation which helps to extend the Strip Light lifetime
FIGURE 1
• Do not fold, crease, twist, or bend the Strip Light at sharp angles
• Use an angle greater than or equal to 90° when there is an LED chip on
the corner while placing the tape in a concave position
• Use an angle greater than or equal to 60° when there is no LED chip on
the corner while placing the tape in a concave position
• Use an angle greater than or equal to 60° when there is an LED chip on
the corner while placing the tape in a convex position. In the convex
position, the angle should not reach 90°
CORRECT
INCORRECT
R≥2-3/8"
CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com
©2024 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.
REV0524
|
SpecFlex Architectural Strip Light
Dry Location Series
• Driver must be installed in a well-ventilated area, free from explosive gases and
vapors. Proper operation requires for free flow of air
• Use Only with Class 2 Power Unit
• Dry Location Only
• For all wire connections use only UL Listed Wire Nuts and Connectors of suitable
size and type
• Wear rubber soled shoes and work on a sturdy wooden or non-conductive ladder
• Double check all connections and screws, ensuring they are tight and correct
• Most dwellings built before 1985 have supply wire rated at 60°C
• Supply conductors (power wires) connecting the fixture must be rated at minimum
of 90°C
• Installing contrary to instructions may cause unsafe conditions
• If the product has any visible damage do not install it
• Call the Technical Support department at ConTech Lighting with any installation
questions: 847.559.5500
FIGURE 2
• The marked cut lines along the Strip Light are indicators of where the
strip can be cut: CUT ONLY ON THE MARKED CUT LINES
• DO NOT CUT STRIP LIGHT WITH POWER CONNECTED
FIGURE 3
• Thoroughly clean the area where the Strip Light will be installed with
isopropal or denatured alcohol
• When installing, avoid excessive pressure on the LEDs and Resistors
• Using fingers only, firmly press down, making sure Strip Light is laying
completely flat, any lifting will cause noticeable changes in light output
• NOTE: DO NOT use any tools to install the Strip Light to a surface, this
will cause damage to the Strip Light
Cut Lines
AFSSDRY INST
P1

Advertisement

loading
Need help?

Need help?

Do you have a question about the ConTech SpecFlex Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Leviton ConTech SpecFlex Series

  • Page 1 INSTALLATION INSTRUCTIONS SpecFlex Architectural Strip Light Dry Location Series The important safeguards and instructions here are not meant to cover all possible conditions and situations that may occur. • WARNING: RISK OF FIRE AND ELECTROCUTION • Driver must be installed in a well-ventilated area, free from explosive gases and vapors.
  • Page 2 INSTALLATION INSTRUCTIONS SpecFlex Architectural Strip Light Dry Location Series The important safeguards and instructions here are not meant to cover all possible conditions and situations that may occur. INSTALLATION PROCEDURE ADHESIVE BACKING Cut Lines • Install and secure the Power Supply in a well-ventilated area, free from explosive gases and vapors;...
  • Page 3 INSTALLATION INSTRUCTIONS SpecFlex Architectural Strip Light Dry Location Series The important safeguards and instructions here are not meant to cover all possible conditions and situations that may occur. INSTALLATION PROCEDURE MOUNTING CHANNELS • ALWAYS WEAR SAFETY GLASSES WHEN CUTTING THE MOUNTING CHANNEL: MOUNTING CLIPS MOUNTING CHANNELS •...
  • Page 4 INSTALLATION INSTRUCTIONS SpecFlex Architectural Strip Light Dry Location Series The important safeguards and instructions here are not meant to cover all possible conditions and situations that may occur. INSTALLATION PROCEDURE RECESSED MOUNTING CHANNEL DIMENSIONS FINISHING THE INSTALLATION • Install and secure the Power Supply in a well-ventilated area, free from 11/16"...