Air Conditioner Features
(continued)
TIMER: DELAY STOP/START FEATURE:
CHECK FILTER FEATURE:
FAULT CODES
If the display reads "AS", a sensor
has failed. Contact your Authorized
Frigidaire Serivice Center
DO THIS:
PRESS TIMER
BUTTON
THEM DO THIS:
PRESS UP (
) OR
DOWN (
) BUTTON
YOU WILL SEE HOW MUCH TIME IS CHOSEN:
Note: For Delay Stop, the unit must be in the On position.
To adjust timer setting, tap or hold the UP arrow( ) Down arrow( )
to change delay timer at .5 hour increments, up to 10 hours, then
at 1 hour increments up to 24 hours. The control will count down
the time remaining until start (8,7.5,7, ete.). The Delay Start mode
automatically selects cooling with maximum Fan Speed. The
temperature maintained will be the same as previously set. To
change the set temperature, Press "COOL" then Up or Down
arrows until the desired temperature is indicated on the display.
After 5 seconds, the control will automatically change the display
back to the hours remaining until the unit will start/stop. Tuming
the unit "ON" or "OFF" at any time will cancel the Delay Start/
Stop function.
The Delay Start/Stop Feature will work until the unit either starts
or stops. Once that happens the above steps have to be repeated
again.
YOU WILL SEE:
Note: This feature is a reminder to clean the Air Filter (See Care
and Cleaning) for more efficient operation and cooling. The LED
(light) will illuminate after 250 hours of operation. To reset after
cleaning the filter, press the "Check Filter" button and the light
will go off.
If the display reads "ES", a sensor
has failed. Contact your Authorized
Frigidaire Service Center