Page 1
OPERATING AND PARTS MANUAL INDUSTRIAL ELECTRIC AIR COMPRESSORS 75UDS AND 100UDS HP MODELS PALATEK, INC. dba SULLIVAN-PALATEK MICHIGAN CITY, IN 46360 ALL RIGHTS RESERVED COPYRIGHT 1994 10/03 Part Number: OPM7510-006S...
Page 3
_____________________________________SULLIVAN-PALATEK SECTION 6 – MAINTENANCE ..................... 22 MAINTENANCE SCHEDULE ..................22 OIL FILTER ..22 1000 EPLACE ELEMENT IF DIFFERENTIAL PRESSURE EXCEEDS PSID OR EVERY HOURS AIR FILTER (I 1000 .) ..23 NSPECT EVERY HRS OR SOONER IN SEVERE DUST CONDITIONS AIR/OIL SEPARATOR ..
SECTION 1 - SAFETY GENERAL SULLIVAN-PALATEK designs all its compressors so they can be operated safely despite the fact that operating a motor driven air compressor can be hazardous. Responsibility for continued safe operation rests with those who install, use and maintain the equipment. The precautions offered in this section will minimize the inherent hazards and reduce the likelihood of accidental damage or injuries.
_____________________________________SULLIVAN-PALATEK Compressed air filters or lubricators with plastic bowls should not be used. Steel bowls are recommended. Keep personnel out of line with, and away from, the discharge opening of air lines, or tools, or other areas of direct, or deflected, compressed air discharge. Do not allow anyone to engage in horseplay with air hoses as serious bodily injury or death may result.
SULLIVAN-PALATEK_____________________________________ PHYSICAL DANGERS Wear OSHA approved personal protective gear including gloves, safety shoes, safety glasses, head covering, and ear protection when working on or around the compressor. Avoid bodily contact with hot oil, hot surfaces, sharp edges and corners. Keep all parts of the body away from all potential points of air discharge, including pressure relief valve ports.
1.11 HAZARD WARNING SIGNS SULLIVAN-PALATEK compressors are all equipped with brightly colored, weather-resistant, pictorial/verbal self-adhesive decals. These are designed to warn the operator against potential hazards to minimize risk of injury or death. All operators must be aware of the Warning Signs and follow the instructions thereon.
SULLIVAN-PALATEK_____________________________________ SIGN LOCATION WARNING - HIGH VOLTAGE/MOVING PARTS MOTOR STARTER WARNING - COMPRESSED AIR INSTRUMENT PANEL WARNING - HOT OIL/PRESSURIZED AIR SEPARATOR TANK SECTION 2 - SPECIFICATIONS MODEL 100G 100D MOTOR SIZE (HP) AIR DELIVER (CFM) MAX. FULL LOAD PRESSURE MIN.
_____________________________________SULLIVAN-PALATEK DATA AND DIMENSIONS SULLIVAN-PALATEK reserves the right to change the design or construction of the above compressor, or to offer them with options which will cause subject equipment to differ from the above specifications, without reference to any descriptions in this manual.
MOTOR The standard motor used to power the SULLIVAN-PALATEK 75 and 100 H.P. compressor is a C-face ODP E-pack premium efficiency motor. Other motors such as TEFC are available upon request.
_____________________________________SULLIVAN-PALATEK INTAKE/CONTROL SYSTEM The intake/control system consists of: an air filter, inlet control valve with a reverse flow check valve incorporated, a modulating or regulating signal pressure control valve, a control pressure switch, a combination unloading/blowdown solenoid valve, and a reverse rotation switch.
Page 12
SULLIVAN-PALATEK_____________________________________ CONTROL SCHEMATIC...
_____________________________________SULLIVAN-PALATEK COMPRESSOR LUBRICATION/COOLING SYSTEM The cooling system consists of a fan, finned-tubed radiator-type fluid cooler, cooler by-pass valve to accelerate warm-up, a full-flow fluid filter, a drain valve and interconnecting tubing. Pressure in the oil separation tank causes the lubricoolant to flow from this region of relatively high pressure through the system to an area of lower pressure at the compressor unit.
SULLIVAN-PALATEK_____________________________________ COMPRESSOR DISCHARGE SYSTEM The compressor unit discharges a mixture of compressed air and lubricoolant directly into the oil separation tank where it accomplishes the following three functions: A) Primary separation - by change of direction and reduction of velocity, which allows the heavier droplets of lubricoolant to drop out.
STARTER AND ELECTRICAL PARTS The three-phase electric motor starter supplied with the SULLIVAN-PALATEK Plant Air Compressor has a NEMA-1 rated enclosure. This enclosure is also the location of: the...
INSTRUMENTATION Each SULLIVAN-PALATEK Plant Air Compressor is equipped with an hourmeter and five gauges. There is one pressure gauge to monitor the oil separation tank pressure, another to monitor line pressure, and a temperature gauge which senses compressor discharge temperature.
SULLIVAN-PALATEK_____________________________________ SECTION 4 - INSTALLATION RECEIVING Carefully inspect for any signs of possible shipping damage. 4.1a Welding Do not weld on compressor package. LOCATION The compressor is designed for indoor operation or protected outdoor site with an ambient temperature range of 35° to 104° F (1° to 40° C). It is important that there be sufficient unobstructed ventilating airflow to prevent re-circulation of hot fan air.
_____________________________________SULLIVAN-PALATEK DIRECTION OF ROTATION Once the control circuit has been checked, all piping installed, and compressor is filled with lubricoolant, connect the three motor leads, momentarily move the selector switch to “Run” then immediately back to “Off/Reset” to check for proper direction of rotation. Rotation should be clockwise when standing at the oil separation tank end, and counter-clockwise from the motor end.
SULLIVAN-PALATEK_____________________________________ SECTION 5 - OPERATION INTRODUCTION Read this entire Operator’s Manual to familiarize yourself with the SULLIVAN-PALATEK Plant Air Compressor, giving special attention to the Section 1 - SAFETY. INITIAL START 1. Open main disconnect to be sure there is no power to the compressor.
_____________________________________SULLIVAN-PALATEK NORMAL OPERATION 1. Open and lock out main power disconnect. 2. Check lubricoolant level. Refill if necessary. 3. Re-close disconnect switch 4. Start machine in either “Run” or “Auto Start/Stop” mode. 5. Fully open service air valve. 6. Observe pressures and temperature. If temperature is incorrect, refer SECTION 6.8 - TROUBLE SHOOTING.
_____________________________________SULLIVAN-PALATEK AIR FILTER (Inspect every 1000 hrs or sooner in severe dust conditions.) Open and lock out main disconnect. Remove air filter element . Blow dust from inside towards outside with low pressure air (less than 30 psi/200 kPa). When reinstalling element be sure it is seated squarely so that dust cannot bypass the filter media.
SULLIVAN-PALATEK_____________________________________ PRESSURE ADJUSTMENT Only the throttling and unload or cut-out/automatic stop pressure can be adjusted. If the plant air service main pressure falls when the compressor is running at full load, more air is being used than the compressor can supply. To raise the pressure at which intake throttling occurs, loosen jam nut on control regulator valve and turn adjustment screw clockwise.
Page 25
_____________________________________SULLIVAN-PALATEK SYMPTON PROBABLE CAUSES AND REMEDY A. MACHINE WILL NOT START 1. Main disconnect open. Close switch. 2. Line fuse(s) blown. Replace fuse(s). 3. Control circuit breaker tripped. Reset circuit breaker. 4. Motor starter overload tripped. Reset. Should trouble persist, check sizing and adjustment of overloads.
Page 26
SULLIVAN-PALATEK_____________________________________ 100-110° F (55-61° C) above ambient; switch is set to trip at 235-245°F (112- 118°C). a. Cooling air flow restricted. Clean cooler and check for proper ventilation. b. Ambient temperature is too high. Provide sufficient ventilation. c. Low lubricoolant level. Add lubricoolant. d.
Page 27
_____________________________________SULLIVAN-PALATEK 3. Improperly adjusted or defective regulator. Readjust or replace if necessary. 4. Defective blowdown valve. Check that sump pressure is exhausted to the atmosphere when unloader pilot valve opens. Replace if necessary. 5. High pressure shutdown switch is defective. Replace. 6.
Page 28
SULLIVAN-PALATEK_____________________________________ PARTS LISTING...
_____________________________________SULLIVAN-PALATEK SCREW COMPRESSOR AIR-END EXCHANGE PROGRAM After the warranty period has expired a factory re-manufactured air-end can be purchased on an exchange basis. All bearings, seals and substandard parts have been replaced. All other parts are inspected to meet our quality standards. The air- end is then factory tested prior to shipment.
SECTION 7 - PARTS LIST PARTS ORDERING Parts should be ordered from the nearest full-service Distributor or Factory Authorized Compressor Center. If parts cannot be obtained locally, contact the factory directly. SULLIVAN-PALATEK 3501 W. DUNES HWY. MICHIGAN CITY, IN 46360 TELEPHONE: 219-874-2497 FAX: 219-872-5043 E-mail: jrissman@palatek.com...
_____________________________________SULLIVAN-PALATEK 7.3 LUBRICATION AND COOLING SYSTEM UDS *REQUIRED FOR ENCLOSED COMPRESSOR PACKAGE ONLY. Water Cooled Machines: 75 hp 100 hp Oil Cooler #00549-004 Oil Cooler #00549-005 After Cooler #00549-005 After Cooler #00549-008 Water Reg. Valve #18338-020 Water Reg. Valve #18338-020...
Page 32
SULLIVAN-PALATEK_____________________________________ LUBRICATION AND COOLING SYSTEM UDS...
_____________________________________SULLIVAN-PALATEK 7.4 MOTOR, COMPRESSOR AND MOUNTING PARTS - BASE MOUNTED UDS 75HP MOTOR 100HP MOTOR #08741-075 #08741-100 TEFC #08747-075 TEFC #08747-100...
Page 34
SULLIVAN-PALATEK_____________________________________ MOTOR, COMPRESSOR AND MOUNTING PARTS – BASE MOUNTED UDS...
_____________________________________SULLIVAN-PALATEK GAUGE PANEL AND ELECTRICAL PARTS UDS * FOR HIGH PRESSURE MACHINES (OVER 150 PSIG., USE 09345-012) ** FOR LOW PRESSURE MACHINES (I.E.<75PSIG) 09344-000...
Page 40
SULLIVAN-PALATEK_____________________________________ GAUGE PANEL AND ELECTRICAL PARTS UDS...
_____________________________________SULLIVAN-PALATEK ENCLOSURE – WATER COOLED UDS *WATER COOLED VENT FAN P.N. 18080-016 1 QUANTITY NOT SHOWN ON DRAWING.
Page 44
SULLIVAN-PALATEK_____________________________________ ENCLOSURE – WATER COOLED UDS...
Sullivan-Palatek’s Obligations: Sullivan-Palatek’s exclusive obligations with respect to breach of warranty are (I) to repair or replace (at Sullivan-Palatek option and subject to return of defective parts) any defective part, (ii) to pay the reasonable cost of making the repair, or installing the replacement part (iii) to pay ground freight for the return of defective parts and shipment of replacement parts.