Page 3
Palatek or 12 months from delivery to the first user. Parts, accessories and attachments sold separately from machines, excluding warranty replacement parts and hand tools: the first to expire; 6 months from shipment by Sullivan-Palatek or 3 months from delivery to the first user.
MANUAL ORGANIZATION NOTE! Anyone operating or servicing the Sullivan-Palatek air compressor should read this entire manual and be familiar with its information. The following is a quick guide to the contents in this manual: SECTION 1: SAFETY This section contains important basic information regarding general safety precautions for maintaining and operating air compressors.
GENERAL SAFETY Safety is a prime consideration in the design and manufacture of the compressor. ultimately, the responsibility for safe operation rests with the individuals who use and maintain the compressor. The following safety precautions are offered as a guide for the safe operation and maintenance of this machinery: »...
» Anti-freeze compound used in airline anti-icing systems contains methanol, which is flammable. use systems and refill with compound only in well-ventilated areas, away from heat, open flames, or sparks. Do not expose any part of these systems or the anti-freeze compound to temperatures above 150°F (65°C).
Under specific guidelines and in full compliance with OSHA Standards 29 CFR 1920 and any other federal, state, or local codes or regulations compressed air can be used for breathing air. Sullivan-Palatek does not provide equipment and instructions for this application and its products are not produced for this application or use.
ENTRAPMENT » Make sure all personnel are out of compressor before closing and latching enclosure doors. larger compressors can hold a man. If it is necessary to enter the enclosure to perform service or adjustments, secure the access door in the open position to avoid the possibility of others closing and latching the door and inform personnel before entering the enclosure.
PORTABLE COMPRESSOR PACKAGE The compressor is a single stage, oil-flooded lubricated rotary screw air compressor. The compressor package is available as a portable wheel-mounted unit, utility mounted unit, or galvanized skid-mounted unit for offshore applications. All models are enclosed in a weather-resistant acoustical enclosure. The complete operating unit consists of a diesel engine for power, compressor assembly, air/oil separator system, cooling system for the engine and compressor oil, instrumentation, pneumatic control system, and acoustical enclosure.
LUBRICATION SYSTEM Figure 3-2. DIAGRAM, OIL PIPING 185-375 (REV 00) Oil from the compressor oil sump at compressor discharge pressure is directed through the cooling system and oil filter to a lower pressure region of the compressor stator. At the same time, oil is directed to the bearings and shaft seal of the compressor.
The engine speed is regulated by a pressure transducer signal through the CANBUS and the Sullivan-Palatek Electronic Controller (SPEC). From full to approximately 60% capacity, the delivery is controlled by engine speed and a gradual closing of the inlet valve. When unloaded the inlet valve is closed to prevent atmospheric air from entering the compressor.
ENGINE SHUTDOWN PROTECTION Sullivan-Palatek uses electronically controlled engines in the 185–1800 CFM line of compressors. Personnel operating and maintaining these compressors MUST be familiar with and understand the operation and protection features available with these engines.
NOTE! The Sullivan-Palatek warranty DOES NOT COVER the engine. The engine and its components are warranted only by the engine manufacturer. Operators, rental customers and anyone responsible for the operation and maintenance of this compressor MuST be instructed and briefed on the proper responses to control module warnings.
05018845 0166 PANEL, INST SINGLE PSI (REV 00) ITEM NAME DESCRIPTION Discharge Air Pressure Gauge Displays discharge air pressure of compressor. Sullivan-Palatek Electronic Monitors the engine and compressor parameters, displays warning and Controller (SPEC) shutdown information, and displays engine diagnostic information from the engine ECU. Ignition Switch START position electrically energizes engine starter motor solenoid.
Page 30
3.11.2 SuLLiVAN-PALATeK eLeCTrONiC CONTrOLLer (SPeC) MODeL PV4380 The Sullivan-Palatek Electronic Controller (SPEC) Model PV4380 monitors all critical compressor and engine parameters, provides warning and shutdown information and has complete engine diagnostic capabilities. Parameters monitored by the SPEC include engine speed, compressor temperature, engine oil pressure, engine temperature, battery voltage and fuel level.
3.12 OPTIONAL EQUIPMENT Sullivan-Palatek offers an extensive variety of options on all portable and utility products. Multiple options are available for each of the sub-categories listed below. Please consult Sullivan-Palatek Sales for more information. 3.12.1 INSTRUMENT PANEL AND PARTS »...
RECEIVING Each compressor is operated and tested at the factory before shipment. This testing assures that the unit is operating properly and that the compressor will deliver its rated capacity. Regardless of the care taken at the factory, there is a possibility that adjustments may be altered or damage may occur during shipment. For this reason it is recommended that the unit be checked for proper operation and carefully inspected before it is put in service.
WARNING! Never add gasoline to diesel fuel tank - serious damage to the engine will result. If necessary, add lubricating oil to the compressor sump. Refer to 5.3 Compressor Lubrication on page 39 for lubricating oil specifications. Check battery posts and cable clamps to assure proper contact. Connect positive cable and negative cable battery terminals.
The exhaust filter cleaning can only be skipped/disabled twice, and then a manual or parked Regeneration must be performed. The compressor is factory set with active automatic Regeneration. To perform a manual or parked Regeneration, refer to 4.9 Sullivan-Palatek Electronic Controller (SPEC) Operating Instructions on page 30 for instructions. INSTAllATIoN AND oPERATIoN...
Page 37
WARNING! Always take precautions while performing either type of Regeneration, as hotter exhaust temperatures may cause a fire or similarly dangerous situation. Refer to the engine manual for proper safety procedures. When an automatic or manual Regeneration is in process, Regeneration icons are shown on the digital display.
SULLIVAN-PALATEK ELECTRONIC CONTROLLER (SPEC) OPERATING INSTRUCTIONS The buttons for operation will be referred to numerically based upon the image at right. Button functionality can vary depending on the operator input required for each page. Pages requiring custom button functionality will display button function icons directly above the buttons.
Page 39
USER SETTINGS MENU user display settings are located here. button 1 cycles through the list of selections; button 3 returns back to the home Page; Button 4 switches between day and night mode (min and max contrast); button 5 saves the settings. Ambient Light: switches between day and light mode;...
Page 40
INTERLOCK ON/OFF 4.) Setting the Interlock to oN, the user must return to the EXhAuST FIlTER STATuS MENu and move down to Request Exh Filter Clean option and a Regeneration will begin. UTILITIES MENU buttons 1 and 2 cycle through the list of selections; button 3 returns back to the home Page;...
DATE AND TIME button 1 moves the selections up and down; buttons 2 and 4 increment the selection up or down; button 3 returns back to the home page; button 5 saves and confirms the settings. DIAGNOSTICS MESSAGE POP-UP Fault codes will generate a pop-up message on screen.
WARNING! Check the compressor sump oil level only when the compressor is not operating and system is completely relieved of pressure. Open pressure relief valve to ensure relief of system air pressure when performing maintenance on compressor air/oil system. Failure to comply with this warning may cause property damage and serious bodily harm or death. 4.11 PNEUMATIC TOOLS APPLICATION WARNING!
4.12 JUMP-STARTING BATTERY WARNING! Always wear an acid-resistant apron, face shield with goggles and gloves when working with batteries! WARNING! Batteries may contain hydrogen gas which is explosive and flammable! Keep flames, sparks and any other source of ignition away. Batteries also contain acid which is corrosive and poisonous. DO NOT allow battery acid to contact eyes, skin, or fabrics.
MAINTENANCE SCHEDULE COMPRESSOR MAINTENANCE SCHEDULE FREQUENCY (HOURS) PROCEDURE SEE NOTE REF� Check oil level (before starting) Check radiator coolant level Check fuel supply (after starting) Check air filter elements 5.10 Check for fuel, oil air and water leaks Drain water from compressor sump Drain water and sediment from fuel tank Change oil filter element Change compressor oil...
When ambient conditions exceed those noted, or if conditions warrant use of “extended life” lubricants, contact Sullivan-Palatek for a recommendation. 5.3.1 CHECK The oil level should be checked daily.
Sullivan-Palatek recommends oil sampling as the best guide for your fluid change interval. Changing fluid once a year my not be adequate or it can be excessive. For this reason an hourly service on lubricants is merely a guide.
OIL SAMPLE FOR ANALYSIS The first oil sample should be drawn after the compressor has run for 500 hours or 3 months. Intervals for following oil samples will be determined by the analysis results. SAMPLE OIL FROM SUMP TANK Run the compressor long enough to reach normal operating temperatures. Turn compressor oFF and allow pressure to blow down to 0 psi.
CURBSIDE SERVICE ACCESS all maintenance points and the SPEC controller display are conveniently located behind the curbside access door. Fuel fill and serviceable parts such as filters can be accessed from this location. All fluid drains are located below the curbside access door. FUEL FILL AIR FILTERS FUEL FILTER...
5.10 AIR INTAKE FILTER Check daily, every 10 hours of operation or on rent return. Replace every 1,000 hours or 6 months. Replace more frequently in dusty conditions. Empty the evacuator valve (dust boot) daily. 5.10.1 REMOVAL AND INSPECTION open the locking devices to remove air filter cover. Remove and inspect the used primary element by turning counter-clockwise to unscrew.
5.16.2 ENGINE SPEED Engine speed is controlled by the Sullivan-Palatek Electronic Controller (SPEC). The full load and idle speeds are programmed at the factory and there should be no need for adjustment. If the machine is experiencing speed problems please contact our Service Department.
INTRODUCTION This section contains instructions for troubleshooting the equipment following a malfunction. Each issue or problem is followed by a list of probable causes and suggested actions to be followed in order to eliminate the cause. The actions listed should be performed in the order listed, although the order may be varied if the need is indicated by conditions under which the problem occurred.
DISCHARGE PRESSURE IS TOO HIGH OR RELIEF VALVE BLOWS POSSIbLE CAUSE ACTION Regulator valve faulty or mis-adjusted Properly adjust the regulator. Rebuild/replace the regulator if necessary. Inlet valve not closing properly Check the white sealing ring for the poppet valve, to ensure it is intact and not damaged.
ENGINE DOES NOT ACCELERATE OR WILL NOT MAINTAIN FULL LOAD SPEED POSSIbLE CAUSE ACTION Compressor discharge pressure too high Adjust the pressure to the maximum operating pressure for the machine. Engine problem Have an authorized engine repair facility inspect the engine.
6.13 COMPRESSOR OIL LEAKING IN CONTROL LINES/ORIFICES POSSIbLE CAUSE ACTION Compressor oil level in sump tank too full Check and adjust compressor oil as needed. Oil return line (scavenger tube) plugged or restricted Remove the oil return line and clean. Separator element plugged or damaged Replace the separator element and change compressor oil.
Use the space provided on the inside cover of the manual to record the model and serial number of the compressor for future reference. 7.1.1 CONTACT INFORMATION For replacement parts and manuals contact: Sullivan-Palatek, Inc. 1201 West US Highway 20 Michigan City, Indiana 46360 Phone: (219) 874-2497 Fax: (219) 872-5043 Toll Free: (800) 438-6203 www.sullivan-palatek.com...
00823062 0010 FLUID, COMPRESSOR WEATHER-ALL (55 GALLON) NOTE! Use only service parts supplied or recommended by Sullivan-Palatek. Use of substitutes may void warranty. See STANDARD WARRANTY for details. SERVICE KITS Service kits are available for basic servicing of the compressor and engine. buying kits offers savings over buying individual parts.
RELEASED FOR PR 18 ZINC PLATED REDRAWN. 03903040 00 5/16-18 X 10.00 BATTERY ASSEMBLY REDRAWN IN SO RY HOLD DOWN ARD 800CCA UNLESS OTHERWISE NOT DIMENSIONS ARE IN INCH TOLERANCES AS FOLLOW ANGLES: + OR - 1/2 DEG. DECIMAL: X.X + OR - 0.05 X.XX + OR - 0.02 X.XXX + OR - 0.0 MATERIAL:...
Page 71
00900321 0003 WASHER, FLAT .3125 ZINC PLATED 00903192 0003 NUT, WING .3125-18 ZINC PLATED 00910106 0230 THREADED ROD, 5/16-18 x 10.00 03903040 0022 BRACkET, BATTERy HOLD DOWN 05017195 0004 BATTERy, STANDARD 800CCA *Batteries not available for purchase through Sullivan-Palatek. PARTS CATAloG...
COMPRESSOR ASSEMBLY ITEM # PART NUMBER 00501170 1436 00925012 1021 KB09147-362 00903686 0008 APPL ALL B - TO A LOCT - TO A LOCT HIGH GREA - TO A LOCT OR EQ UNLESS DIMENSI TOLERAN ANGLES DECIMAL MATERIAL: FIRST USED THIS DRAW IT IS LOANED Figure 7-8.
Page 77
00717488 0146 COMPRESSOR ASSEMbLY ITEM PART NUMbER DESCRIPTION 00501170 1436 AIR END, 127MM, 2.0278 GR 00925012 1021 SCREW, HEx HD M10-1.5 x 35MM GR 8.8 ZN PLT KB09147-362 SEAL, SHAFT 3 LIP, CW (NOT SHOWN) 00903686 0008 UNION, MALE ELBOW 3/4 x 3/4NPT PARTS CATAloG...
GREASE OR EQUIVALENT - TO ALL PIPE THREADS: LOCTITE 567 THREAD SEALANT COMPRESSOR (REF) OR EQUIVALENT Figure 7-13. 00717886 0010 (REV 00) SULLIVAN-PALATEK UNLESS OTHERWISE NOTED DRAWN BY: DATE: DIMENSIONS ARE IN INCHES 11/11/15 PARTS CATAloG 1201 West US Highway 20, Michigan City IN 46360...
Page 87
00717886 0010 DISCHARGE ASSEMbLY ITEM PART NUMbER DESCRIPTION 00909753 0036 FLANGE, ELBOW 2" CODE 61 TO NPTF 00909753 0033 FLANGE, ELBOW 2" CODE 61TO NPTF W 1/2 MNPT 00909753 0032 KIT, SPLIT FLANGE-SAE 4BOLT 2" 00901177 0252 NIPPLE, PIPE 2" x 9" SCH 80 GALV 00906058 3224 NIPPLE,HEx PIPE,2 x 1-1/2 NPT 03903344 0115...
7.23 FRAME ASSEMBLY ITEM # PART NU 00900115 03903313 0 03903009 0 00900490 00901921 00901921 00913792 01901472 00915786 00915786 - TO - TO - TO UNLESS OTHERWISE NOTED DIMENSIONS ARE IN INCHES TOLERANCES AS FOLLOWS: ANGLES: + OR - 1/2 DEG. DECIMAL: X.X + OR - 0.050 X.XX + OR - 0.020 X.XXX + OR - 0.005...