Page 1
This Owner's Manual is provided and hosted by Appliance Factory Parts. GENERAL MAC1200 Owner's Manual Shop genuine replacement parts for GENERAL MAC1200 Find Your GENERAL Air Cleaner Parts - Select From 69 Models -------- Manual continues below --------...
Page 2
Product Badge ® (For Proper Upright Placement During Field Installation) The GeneralAire TERSus Air Purification System installs into the return side of ducted HVAC appliances. The GeneralAire TERSus Air ® ® Purifier not only removes particles, but also attacks viruses, germs, and toxic gases.
® TERSus 1200 & 2000 Table of Contents Safety Considerations Specifications Removing & Replacing the Door Installation Wiring Diagram Maintenance 9-10 GeneralAire TERSus Air Purification Operation ® Cleanup of Broken Lamps Replacement Parts List Troubleshooting Guide WARNING! This symbol indicates: IMPORTANT INSTRUCTIONS! Failure to heed them can result in serious injury or death.
TERSus Installation Manual Model 1200 (GFI #4570) & Model 2000 (GFI #4560) Safety Considerations WARNING: Never expose eyes or skin to UVC light from any source. • Looking directly at the UVC light may cause permanent eye damage or blindness. •...
® Specifications Model TERSus 1200: Model TERSus 2000: Capacity: 1.5 to 3.0 tons Capacity: 1.5 to 4.0 tons Power: 120V/60 Hz .6 Amps 49.2 Watts Power: 120V/60 Hz .6 Amps 49.2 Watts Fuse: Replace only with AGC-2 fuse Fuse: Replace only with AGC-2 fuse Application: 1.5 to 3 Ton Drive Air Handler/Furnace...
TERSus Installation Manual Model 1200 (GFI #4570) & Model 2000 (GFI #4560) Removing & Replacing the Door To REMOVE the door to the TERSus system follow these steps: 1. Twist the two locking knobs such that they are vertical to the short edge of the unit. (See Figure 1) 2.
Page 7
® Installation, Cont. WARNING: Make sure unit is unplugged before installing the lamp. Make sure to install the TERSus so that the inlet or return air enters the side containing the MERV 13 particulate reduction filter cartridge first. TiO2 Catalyst Side Filter Cartridge Side Air Flow Remove the door to the unit per the steps listed previously.
Page 8
TERSus Installation Manual Model 1200 (GFI #4570) & Model 2000 (GFI #4560) Installation, Cont. Air Handler or Furnace TERSus Purifier Air Handler Furnace or Furnace Blower Door GeneralAire ® Badge ® Placement GeneralAire ® ® Badge Furnace TERSus Placement Blower...
® Wiring Diagram White Ballast Lamp 120/220V Black White Ballast Lamp 120/220V Black Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause WARNING: permanent eye damage or blindness. Never operate the TERSus outside ductwork. Avoid touching the glass portion of the lamp with bare (ungloved) hands.
TERSus Installation Manual Model 1200 (GFI #4570) & Model 2000 (GFI #4560) Maintenance Frequency WARNING: Disconnect power to the unit before commencing inspection and cleaning. CAUTION : Wear disposable, non-absorbent protective gloves prior to inspection procedure in case of accidental glass breakage. Inspect and clean the lamp at least every 6 months.
Page 11
® Replacing the Lamps Recommended every 12 months of continuous service. • Replace only with a germicidal replacement lamp; GFI #4564. • Follow the steps to remove the lamp (Figure 12). Replace with the new replacement lamp. CAUTION : If blue light leaks through any portion of ductwork, immediately unplug power supply cord and seal affected areas. UV lamps contain a small amount of mercury, like a typical fluorescent lamp.
TERSus Installation Manual Model 1200 (GFI #4570) & Model 2000 (GFI #4560) GeneralAire TERSus Air Purification Operation ® The TERSus Air Purification System installs in the air-inlet side of any heating and air conditioning system. Only operation of the air- handler fan unit is required for filtration, air purification, and sterilization to take place.
Replacement UVC Lamps (Set of 2) GFI #4565 BTO-12/20 Replacement Ballast Assembly GFI #4581 1625 MERV 13 Filter w/Carbon (TERSus 1200) GFI #4582 2025 MERV 13 Filter w/Carbon (TERSus 2000) Troubleshooting Guide My lamps do not light up when I plug the unit back in.
Need help?
Do you have a question about the TERSus 1200 and is the answer not in the manual?