GF-200D
(Duct Mount)
30.5
200
up to 2200 Sq. Ft.
Air Flow From Furnace Through Air Cleaner
1. HEPA - Replace Every 2 Years (GF-4645) / 2. Pre-Filter With Carbon (GF-4646) - Replace Every 3- 6 Months
120
115V / 1 / 60Hz; 1.30 Amp
Return Air Duct
HEPA Air Cleaner, 9' Power Cord, Installation Manual,
Duct Collars, Pre-Filter, HEPA Filter, 3 Mounting
Brackets, Screws, Mounting Template
GF-200 / GF-400 Series HEPA Air Cleaners
GF-400D
(Duct Mount)
35
24 H x 12.75 D x 17 W
400
up to 4200 Sq. Ft.
HEPA 99.97%
300
115V / 1 / 60Hz; 2.75 Amp
CSA
C
Collar: 8 (203 mm)
Intake: 3.75 (95 mm) x 14.375 (365mm)
Exhaust: 3.75 (95 mm) x 14.375 (365mm)
18
5
** CFM calculation: ACH X Volume ( Cubic Feet L x W x H) /60=CFM
Square Footage calculations based on average of 0.70ACH
24" H
24" H
GF-200R
(Room/Portable)
30.5
200
up to 2200 Sq. Ft.
Room / Portable
120
115V / 1 / 60Hz; 1.30 Amp
115V / 1 / 60Hz; 2.75 Amp
US
Room / Portable
HEPA Air Cleaner, 9' Power Cord, Installation Manual,
Pre-Filter, HEPA Filter, Screws, Caster Wheels
GF-200D & GF-400D
GF-200R & GF-400R
70081850
GF-400R
(Room/Portable)
35
400
up to 4200 Sq. Ft.
300
400 Midwest Rd.
Toronto, ON M1P 3A9
(888) 216-9184
www.GeneralaireIAQ.ca

Advertisement

loading

Summary of Contents for GeneralAire GF-200 Series

  • Page 1 GF-200 / GF-400 Series HEPA Air Cleaners GF-200D & GF-400D GF-200R & GF-400R HEPA AirCleaners Installation Manual Please Read And Save These Instructions 24” H 24” H 70081850 GENERALAIRE HEPA AIR CLEANERS ® GF-200D GF-400D GF-200R GF-400R Model (Duct Mount)
  • Page 2 INSTALLATION  • WARNING: Disconnect electrical power before beginning installation. 1. Before Installing Your New Surface or Duct Mount HEPA Air Cleaner, Determine: • Location on the return side of the duct for installation of your HEPA 200D or 400D. •...
  • Page 3 INSTALLATION CONT. Duct Mount HEPA (Models GF-200D / GF-400D) 1. Install mounting support bracket on return air duct for bottom support using the provided #8 x 1/2” screws. 2. Install the side mounting brackets on both sides of the unit by removing and remounting the screws located on the unit.* Intake...
  • Page 4 MAINTENANCE  IMPORTANT: To ensure your safety and the longevity of your unit, we recommend: • Contacting a licensed contractor to perform maintenance or repairs.  • WARNING: Disconnect electrical power before beginning maintenance. 1. Replace your pre-filter with (GF-4646) every 3 to 6 months. carbon 2.