TSUNESS TSUN TSOL-MX500 Balcony User Manual

Balcony microinverter

Advertisement

Quick Links

Balcony Microinverter
Balcony Microinverter
V1.0
- 1 -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TSUN TSOL-MX500 Balcony and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TSUNESS TSUN TSOL-MX500 Balcony

  • Page 1 Balcony Microinverter Balcony Microinverter V1.0 - 1 -...
  • Page 2: Table Of Contents

    Readers are cautioned, however, that TSUN Smart Monitoring guide ..................- 8 - TSUNESS reserves the right to make changes without notice and shall not be responsible Maintenance Guide ...................... - 9 - for any damages, including indirect, incidental, or consequential damages, caused by reliance on the material presented, including, but not limited to, omissions, typographical Routine Maintenance .......................
  • Page 3: Read This First

    Product Label This device fulfills the requirements of the Radio Equipment Directive. TSUNESS Co., Ltd declares that the radio equipment (Micro inverter) is in The following safety symbols are used in this document. Familiarize yourself with the complies with Directive 2014/53/EU. The full text of the EU Declaration of symbols and their meaning before installing or operating the system.
  • Page 4: System Introduction

    Balcony Microinverter This device complies with the RoHS Directive. There is a risk of electric shock during energy conversion. Before releasing the remaining voltage, do not perform any operations and do not enter within 25 centimeters of the surrounding area. System Introduction Product Description The Balcony microinverter is used in grid-tied applications, comprised of two key...
  • Page 5: Microinverter Installation

    Balcony Microinverter Screw M6*16 ⑦ Expansion Screw M8*40 ⑧ Expansion Screw M5*40 ⑨ Microinverter Installation Balcony Microinverter(4PV) Pre-installation Check Mounting Hole AC Cable Check the Package Grounding Hole Antenna DC Cables Status Light Although TSUN microinverters have surpassed stringent testing and are checked before they Packing List leave the factory, it is uncertain that the microinverters may suffer damage during transportation.
  • Page 6 Balcony Microinverter Installation Steps DANGER ·Before installation, check the unit to ensure the absence of any transport or handling damage, which could affect insulation integrity or safety clearances. ② ·Unauthorized removal of necessary protections, improper use, incorrect installation, and ③ operation may lead to serious safety and shock hazards or equipment damage.
  • Page 7 Balcony Microinverter  Wall Installation Step 4. Connect AC end cable WARNING Using two pairs of screws and nuts to ·Ensure that all AC cables are correctly wired and that none of the wires are pinched or damaged. fix the microinverter on the frame. Make sure that the label of microinverter should be upside.
  • Page 8: Tsun Smart Monitoring Guide

    Balcony Microinverter ·Ensure that all DC cables are correctly wired and that none of the wires are pinched or damaged. ·The maximum open circuit voltage of the PV module must not exceed the specified maximum input DC voltage of the TSOL microinverter. CAUTION ·If the DC cable is too short for installation, use a DC Extension Cable to connect PV modules to the microinverter.
  • Page 9 Balcony Microinverter Register An Account  Wrong network configuration steps  Downloaded the wrong app  Click “Register” to create account,Choose“End-user”  bad network signal  Fill in all registration details & read the T&C and Privacy Policy,then complete registration (Note:If the fault cannot be eliminated after the above inspection, please contact after-sales ...
  • Page 10: Storage And Dismantling

    Balcony Microinverter Warranty Service maintenance.  During normal operation, check that the environmental and logistic conditions are appropriate. We make the following commitments to Tsun's balcony products Make sure that the conditions have not changed over time and that the equipment is not exposed to adverse weather conditions and has not been covered with foreign bodies.
  • Page 11: Technical Data

    Balcony Microinverter Technical Data TSOL-MX500 TSOL-MX450 TSOL-MX400 TSOL-MS400 TSOL-MS350 TSOL-MS300 Model Balcony Balcony Balcony Balcony Balcony Balcony Input Data (DC) Recommended Module Power (W) 300 ~ 700 300 ~ 700 300 ~ 700 300 ~ 550 300 ~ 550 300 ~ 550 Start-up Voltage per Input (V) Rated Input Voltage (V) MPPT Voltage Range per Input (V)
  • Page 12 Balcony Microinverter TSOL-MX1000 TSOL-MX900 TSOL-MX800 TSOL-MS800 TSOL-MS700 TSOL-MS600 Model Balcony Balcony Balcony Balcony Balcony Balcony Input Data (DC) Recommended Module Power (W) 300 ~ 700 300 ~ 700 300 ~ 700 300 ~ 550 300 ~ 550 300 ~ 550 Start-up Voltage per Input (V) Rated Input Voltage (V) MPPT Voltage Range per Input (V)
  • Page 13 Balcony Microinverter Model TSOL-MS2000(600) TSOL-MS2000(800) TSOL-MS1600 TSOL-MS1800 TSOL-MS2000 Input Data (DC) Recommended Module Power (W) 300 - 700 300 - 700 300 - 700 300 - 700+ 300 - 700 Start-up Voltage per Input (V) Rated Input Voltage (V) MPPT Voltage Range per Input (V) 16~60 Max.
  • Page 14 Balcony Microinverter General Data for all Balcony Microinverter WiFi module for all Balcony Microinverter Peak Inverter Efficiency 96.7% WiFi Standard 802.11b/g/n CEC Weighted Efficiency 96.5% WiFi Frequency Range 2.412GHz-2.472GHz Nominal Mppt Efficiency 99.9% 802.11b: +17dBm + 1.5dBm (@11Mbps) Nighttime Power Consumption <50mW Display LED indicators;...
  • Page 15 Balcony Microinverter V1.0 - 15 -...

Table of Contents