Hide thumbs Also See for AF10G4ACEv2:

Advertisement

Quick Links

User Guide
AF10G4ACEv2
05/2024
Release Version: 49410c03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AF10G4ACEv2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Garland AF10G4ACEv2

  • Page 1 User Guide AF10G4ACEv2 05/2024 Release Version: 49410c03...
  • Page 2 The Garland Technology trademarks, service marks ("Marks") and other Garland Technology trademarks are the property of Garland Technology, LLC. PacketMAX Series products of marks are trademarks or registered trademarks of Garland Technology, LLC. You are not permitted to use these Marks without the prior written consent of Garland Technology.
  • Page 3: Table Of Contents

    Interfaces ..............................11 LEDs ................................. 11 Service Node ............................... 12 Deduplication .............................. 12 Packet Parsing and Masking ........................12 Deduplication Performance ........................13 Time Stamping ............................13 Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 4 Egress Insertion Control .......................... 23 Egress Stripping Control .......................... 25 Stats ................................. 27 Configuration ............................28 Timing Mode ............................29 Restart Application ..........................30 Reboot/Shutdown Appliance ........................31 Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 5: Safety Warning Statements

    Ultimate disposal of this product should be handled according to all national laws and regulations. Warning This equipment is not suitable for use in locations where children are likely to be present. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 6: Emc Statements

    • defined in IEC 60364-3:1993): – TN-S – TN-C – – In addition, if equipment is operated in a domestic environment, radio-frequency interference may occur. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 7: List Of Components Supplied

    PacketMAX| AF10G4ACEv2 | 49410c03 List of Components Supplied The components supplied with each AF10G4ACEv2 are listed below. If any component is found to be missing, damaged, not working, or otherwise faulty, please report it immediately to Garland Technology Technical Support.
  • Page 8: Technical Specifications

    EN61000-3-2, EN61000-3 (EU) • EN55024 (EU) • Meets VCCI:V-3/2015.04 Class A ITE Emissions (Japan) • • Meets AS/NZS CISPR 22:2009/A1:2010 Class A ITE emissions (Australia/New Zealand) Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 9: Introduction

    Hardware As shown in Figure 1, the AF10G4ACEv2 is a small form factor appliance, complete with an x86 CPU subsystem, that performs advanced packet conditioning applications. The hardware design is illustrated in Figure 1. The main building blocks are the FPGA Motherboard, x86 ComExpress Modules, and a network Interface featuring a 4 x10G SFP+ frontend, and a 40G QSFP.
  • Page 10: Front Panel

    P2 AMBER LED - P2 GREEN LED - Link/Activity P1 AMBER LED - P1 GREEN LED - Link/Activity P0 AMBER LED - P0 GREEN LED - Link/Activity Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 11: Rear Panel

    PacketMAX| AF10G4ACEv2 | 49410c03 Rear Panel Interfaces AC Input - Power Input LEDs Power Switch GREEN LED - GREEN – AC power applied and switch ON Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 12: Service Node

    PacketMAX| AF10G4ACEv2 | 49410c03 Service Node The AF10G4ACEv2 Service Node connects to device ports that send it streams of packets for packet conditioning on 10G or 40G ports. The AF10G4ACEv2 performs the required packet conditioning function on each ingress stream and performs a U-Turn on each link and returns the stream in the egress direction on the same device port.
  • Page 13: Deduplication Performance

    850ms dedupe window. Time Stamping The AF10G4ACEv2 timestamps all packets at ingress. The timestamp is internally a 64-bit integer, with 32-bits of seconds and 32-bits of sub-seconds. The resolution is that of the FPGA main clock, namely 5ns.
  • Page 14: Configuration

    5: egress stripping control 6: stats 7: configuration 8: restart application 9: reboot/shutdown appliance 10: interface mode 11: timing mode 2. Enter 1-11 (rt) for the desired option. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 15: Interface Mode

    9. Enter 0 (rt) to exit the interface mode menu. The main menu will be displayed. 10. Enter 8 (rt), to restart application. The main menu will be displayed. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 16: Display The Saved Configuration

    40G timingmode internal 3. Enter 0 (rt) to exit the configuration menu. The main menu will be displayed. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 17: Deduplication Control

    8. Enter 1 (rt) to ignore MPLS tags with deduplication. 9. Enter 2 (rt) to include MPLS tags with deduplication. 10. Enter 0 (rt) to exit the deduplication control menu. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 18 40G timingmode internal 14. Enter 0 (rt) to exit the configuration menu. The main menu will be displayed. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 19: Slicing Control

    (-1) or (-2) or (-3) or number of bytes 5. Enter 0 (rt) to exit the slicing control menu. The main menu will be displayed. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 20 40G timingmode internal 9. Enter 0 (rt) to exit the configuration menu. The main menu will be displayed. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 21: Parser Control

    PacketMAX| AF10G4ACEv2 | 49410c03 Parser Control For the AF10G4ACEv2 to perform accurate de-duplication, the parser skips encapsulating headers by default to isolate the actual IP packet of interest and masks volatile IP header fields. If desired encapsulating headers may be included via enabling awareness. All header types are disabled by default.
  • Page 22 16. Enter 0 (rt) to exit the configuration menu. The main menu will be displayed. Enter 8 (rt) to restart application. The main menu will be displayed. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 23: Egress Insertion Control

    12. Enter 7 (rt) to access the configuration menu. The configuration menu will be displayed. 13. Enter 2 (rt) to save the configuration. 14. Enter 1 (rt) to display the saved configuration. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 24 40G timingmode internal 15. Enter 0 (rt) to exit the configuration menu. The main menu will be displayed. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 25: Egress Stripping Control

    12. Enter 11 (rt) to disable GTP-U stripping. 13. Enter 12 (rt) to enable GTP-U stripping. 14. Enter 13 (rt) to disable IP-in-IP stripping. 15. Enter 14 (rt) to enable IP-in-IP stripping. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 26 24. Enter 0 (rt) to exit the configuration menu. The main menu will be displayed. 25. Enter 8 (rt) to restart application. The main menu will be displayed. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 27: Stats

    Stats Ingress and egress statistical information may be displayed on the AF10G4ACEv2. If the unit is in the 10G mode, then ports 0, 1, 2 and 3 display statistical information. If the unit is in the 40G mode, then port 4 display statistical information.
  • Page 28: Configuration

    6. Enter 7 (rt) to print the version information. SDK: SDK_1_2_20210928 firmware: 49410c03 7. Enter 9 (rt) to set up the network configuration. This process is discussed in the Quick Start Guide. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 29: Timing Mode

    7. Enter 2 (rt) to save the configuration. 8. Enter 0 (rt) to exit the configuration menu. Enter 8 (rt) to restart application. The main menu will be displayed. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 30: Restart Application

    Applications that require restart: Parser Control Egress Stripping Control Timing Mode 1. On the Main Menu enter 8 (rt) to restart application. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.
  • Page 31: Reboot/Shutdown Appliance

    3. Enter 2 (rt) to gracefully shutdown the unit. A graceful shutdown should always be executed before the unit is turned off or AC power removed. Garland Technology | 716.242.8500 | garlandtechnology.com/support Copyright © 2024 Garland Technology, LLC. All rights reserved.

Table of Contents