Filter grille technical measures, such as reciprocal switches interlocking, etc. If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.
Use carefully. They contain important you may find descriptions of individual information concerning your personal features that do not apply to your safety as well as on use and care of the specific appliance. appliance. This extractor hood complies with all Please retain the operating and relevant safety regulations.
Fan ON and appropriate intervals, the possibility of them speed increase speed catching fire as a result of a build-up of heat Intensive setting such as occurs when deep-fat frying or roasting is taking place, is reduced. Display for fan setting Switching the fan ON Cleaning the metal grease filters:...
Page 6
1. Press the catch on the grease filters (see "Removing and inserting the metal- inwards and fold the filters down. mesh grease filters"). At the same time take hold of the under- 2. Insert the activated carbon filter. side of the grease filters with your other hand.
Clean the operating buttons with a mild Caution: Refer for plug-in lampholder. soapy solution and a soft, damp cloth only. Take hold of the bulb with a clean cloth. Do not use stainless-steel cleaner to clean the operating buttons. Stainless steel surfaces: Use a mild non-abrasive stainless steel cleaner.
Only one side of the extractor hood Please ask your dealer or inquire at your may be installed next to a high-sided unit local authority about current means of or high wall. Gap at least 50 mm.
flue that is interlocking, etc. currently used for other purposes, nor into a shaft that is used for ventilating rooms in If the air intake is inadequate, there is a which stoves or fireplaces are also located.
Short, smooth air exhaust pipe. Mount the pipe directly onto the air As few bends in the pipe as possible. outlet on the hood. Diameter of pipe to be as large as possible and no tight bends in pipe.
90 cm 20,4 20,9 regulations. If possible, site the earthed socket directly We reserve the right to construction changes within the behind the chimney panelling. context of technical development. The earthed socket should be connected via its own circuit. If the earthed socket is no longer...
4. Drill 4 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling. Insert plugs into the holes so that they are flush with the wall.
Page 13
07. Screw in lower screws (hex screws). 11. Remove the protective film from the two flue ducts. 08. Stick protective film over the holes of the 2 lower mounting bolts in the Take care not to damage the protective grid.