Image Logging

4-1-1

Logging Conditions (Image Logging)

Support measurement functions

This is used when saving measurement images to on-board memory, RAM-
Disk or USB memory.
This enables preparation of logging conditions using an expression and is
more flexible than the system image logging conditions settings.
However, the settings of this unit are enabled if „None" is set on the [Logging
setting] of the main screen [Measure] menu.
If settings that perform image logging for multiple units during measurement
are executed, the last settings executed are enabled.
• This is used when saving logging images under specific conditions.
Setting item
Set value [Factory default]
Logging condition
• [None]
• Only NG
• All
SECTION 4
Description
No images are saved.
Saves images only if an NG
occurs.If an NG occurs down-
stream from the image logging
processing unit, image logging
is not performed.
Insert image logging as close to
the end of the scene as possible
All measured images are saved.