Omron WS02-CXPC1-V9 - V9 Operation Manual page 95

Table of Contents

Advertisement

Instruction Support and Operand Restrictions
• If "not fixed" is indicated in parentheses, the size used by the instruc-
tion for reading, writing, or other processing can be changed. Make
sure that the maximum size required for the number of array elements
is provided.
Even if the number of array elements in an operand with unfixed size
does not match the size specified in another operand, the CX-Pro-
grammer will not output an error when compiling. The instruction will
operate according to the size specified in the other operand, regard-
less of the number of array variable elements.
---: Operands that do not require an AT setting or specification of array vari-
ables.
Note When specifying the first or last word of multiple words in an in-
struction operand, input parameters cannot be used to pass data
to or from variables. Either an AT setting must be used or one of the
following must be used: 1) An input-output variable set to an array
must be used and the address of the first word must be set for the
input parameter (CX-Programmer version 7.0 or higher) or 2) An
array variable with the required number of elements must be pre-
pared, and after the array data is set in the function block definition,
the first or last element in the array variable must be specified for
the operand.
• Any operands for which an AT setting must be specified for an I/O mem-
ory address on a remote node in the network are indicated as Specify
address at remote node with AT setting in the AT setting or array required
column.
The following table lists all of the instructions supported by the CS/CJ-series
CPU Units, CP-series CPU Units, NSJ-series NSJ Controllers, and FQM1
Flexible Motion Controllers (unit version 3.0 or later).
• Some instructions are supported only by FQM1 Flexible Motion Control-
lers (unit version 3.0 or later). These are indicated by "FQM1 only" under
the mnemonic.
• There are also instructions that are supported only by the CS/CJ-series
CPU Units, CP-series CPU Units, and NSJ-series NSJ Controllers, i.e.,
that cannot be used by the FQM1 Flexible Motion Controllers (unit version
3.0 or later). Refer to the FQM1 Instructions Reference Manual (Cat. No.
O013) to confirm the instructions that are supported.
For details, refer to the Programmable Controllers Instructions Reference
Manual (Cat. No. W474).