Omron WS02-CXPC1-V9 - V9 Operation Manual page 126

Table of Contents

Advertisement

Procedures
Note
Inputting Values in Parameters
Input variable data
type
BOOL
Bit data
INT
Integer
DINT
Double integer
LINT
Long (4-word) inte-
ger
UINT
Unsigned integer
UDINT
Unsigned double
integer
ULINT
Unsigned long (4-
word) integer
100
2. Set the source address from which to pass the address data to the input
variable. Also set the destination address to which the address data will be
passed from the output variable.
Set the data in all the input parameters. If even a single input parameter
remains blank, the left bus bar for the instance will be displayed in red to indi-
cate an error. If this happens, the program cannot be transferred to the CPU
Unit.
The following table lists the methods for inputting values in parameters.
Content
Size
1 bit
16 bits
32 bits
64 bits
16 bits
32 bits
64 bits
Input the address from which to pass data
to the input variable.
The value of 001 is passed to input
variable aaa.
Input method
P_Off, P_On
Positive value: & or + followed
by integer
Negative value:
followed by
integer
Positive value: & or + followed
by integer
Section 3-2
Instance name
Function block definition
Press the P Key with the cursor on the left
of the instance. The New Parameter
Dialog Box will be displayed.
Setting range
0 (FALSE), 1 (TRUE)
32768 to +32767
2147483648 to +2147483647
9223372036854775808 to
+9223372036854775807
&0 to 65535
&0 to 4294967295
&0 to 18446744073709551615