Function Block Holding Area (H512 to H1535)
The default allocation of Function Block Holding Area words set as retained
and non-retained words is H512 to H1535. These words are different to the
standard Holding Area used for programs (H000 to H511), and are used only
for the function block instance area (internally allocated variable area).
• These words cannot be specified in AT settings for internal variables.
• These words cannot be specified as instruction operands.
• These words are displayed in red if they are input when a function
block is not being created.
• Although the words can be input when creating a function block, an
error will occur when the program is checked.
• If this area is specified as non-retained, turn the power ON/OFF or clear
the area without retaining the values when starting operation.
To prevent overlapping of instance area addresses with addresses used in the
program, set H512 to H1535 (Function Block Holding Area words) for the non-
retained area and retained area. If there are not sufficient words, use words in
areas not used by the user program.
FQM1 Flexible Motion controller
FB Instance
Area
Start address
Non Retain
5000
Retain
None
Timers
T206
Counters
C206
Non-retained Areas
Item
Allocated variables
Variables for which the retain property for power OFF and
operation start is set as retained. (See note 1.)
Applicable areas
I/O (CIO), W (Work Area), and D (DM Area) (See note 2.)
Setting unit
Set in words
Allocated words
CIO 5000 to CIO 5999
(default)
(1) Except when the data type is set to TIMER or COUNTER.
(2) Bit data can be accessed even if the DM Area is specified for the non-re-
tained area.
Retained Area
None
Timer Area
Item
Allocated variables
Variables with TIMER set as the data type.
Applicable areas
T (Timer Area) Timer Flag (1 bit) or timer PVs (16 bits)
Allocated words
T206 to T255 Timer Flag (1 bit) or timer PVs (16 bits)
(default)
Counter Area
Item
Allocated variables
Variables with COUNTER set as the data type.
Default value
End address
Size
5999
1000
T255
50
C255
50
Contents
Contents
Contents
Section 2-3
Applicable memory
areas
CIO, WR, DM
TIM
CNT
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac cx-programmer 9Sysmac ws02-cxpc1-v9

Table of Contents